With increasing power system complexities, fault becomes more common which makes the equipments and workers exposed to catastrophes. Previously supervisory control and data acquisition(SCADA) system were used to monitor and detect fault in power system, but it's lower sampling rate makes it inappropriate to use. This paper presents an improved approach for fault detection in distribution line. The proposed method uses Phasor Measurement Units (PMU)to detect fault quickly and operate the circuit breakers(CB) to ensure system stability and security. For this purpose 30 kW generating station feeding power to 10 km distribution line with a step up transformer (208/11 kV) and a 24 kW solar photovoltaic(PV)module is used here. PMU's are installed at synchronous generator, PV grid, and load buses respectively. The data from the PMU are aligned and planned to IEEE C37.118 format before transmitted to the Phasor data concentrator. Here, positive sequence phase locked loop (PLL) based PMU is used to measure the power system parameters like voltage, frequency, and phase respectively. The large deviation in any parameter can be used to trigger the CB. Quick and Accurate fault detection in the distribution network eliminates any big catastrophic effect and saves from monetary loss. The performance of the proposed model can be evaluated by calculating Total Vector Error of the PMU and then comparing it with IEEE C37.118 standards. Proposed scheme also provides optimal placement of PMU in the given system.
引用
收藏
页码:76 / 81
页数:6
相关论文
共 50 条
  • [1] Optimal Placement of Phasor Measurement Unit System on the Hungarian Transmission Network
    Galo, Andras
    Farkas, Csaba
    Gregus, Zoltan
    9TH INTERNATIONAL YOUTH CONFERENCE ON ENERGY, IYCE 2024, 2024,
  • [2] Multistage Optimal Placement of Phasor Measurement Unit
    Shyam, Chaw Chuaong
    Rabha, Papu
    Sinha, Ashoke Kumar
    2015 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS SUSTAINABLE GROWTH (ICEPE), 2015,
  • [3] the Method of Optimal Phasor Measurement Unit Placement
    Zhang Wen-jun
    Xu Jian-jun
    Xing Long
    ADVANCES IN APPLIED SCIENCE AND INDUSTRIAL TECHNOLOGY, PTS 1 AND 2, 2013, 798-799 : 298 - +
  • [4] Optimal placement of phasor measurement unit in distribution networks considering the changes in topology
    Su, Hongzhi
    Wang, Chengshan
    Li, Peng
    Liu, Zhelin
    Yu, Li
    Wu, Jianzhong
    APPLIED ENERGY, 2019, 250 : 313 - 322
  • [5] Phasor measurement unit based local fault detection in distribution systems
    Greber, Marton
    Fodor, Attila
    Magyar, Attila
    IFAC PAPERSONLINE, 2022, 55 (09): : 36 - 41
  • [6] A Brief Study on Optimal Placement of Phasor Measurement Unit
    Kaushal, Kajal
    Syal, Poonam
    Sinha, S. K.
    3RD INTERNATIONAL CONFERENCE ON INNOVATIVE APPLICATIONS OF COMPUTATIONAL INTELLIGENCE ON POWER, ENERGY AND CONTROLS WITH THEIR IMPACT ON HUMANITY (CIPECH-18), 2018, : 215 - 220
  • [7] An improved optimal phasor measurement unit placement algorithm
    Li, Qiang
    Yu, Er-Keng
    Lü, Shi-Chao
    Pan, Yi
    Zhou, Jing-Yang
    Power System Technology, 2005, 29 (12) : 57 - 61
  • [8] A Strategic and Significant Method for the Optimal Placement of Phasor Measurement Unit for Power System Network
    Baba, Maveeya
    Nor, Nursyarizal B. M.
    Sheikh, M. Aman
    Irfan, Muhammad
    Tahir, Mohammad
    SYMMETRY-BASEL, 2020, 12 (07):
  • [9] Optimal Placement of Phasor Measurement Unit for Observation Reliability Enhancement
    Van-Khoi Tran
    Zhang, He-sheng
    Van-Nghia Nguyen
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (03) : 996 - 1006
  • [10] Optimal Phasor Measurement Unit Placement by an Improved PSO Algorithm
    Wang, Jian-ming
    Li Chuandong
    Zhang, Jian
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,