Performance characteristics and parametric optimization of an irreversible magnetic Ericsson heat-pump

被引:4
作者
Wei, Fang [1 ,2 ]
Lin, Guoxing [1 ,2 ]
Chen, Jincan [1 ,2 ]
Bruck, Ekkes [3 ]
机构
[1] Xiamen Univ, Dept Phys, Xiamen 361005, Peoples R China
[2] Xiamen Univ, Inst Theoret Phys & Astrophys, Xiamen 361005, Peoples R China
[3] Delft Univ Technol, Fac Sci Appl, NL-2629 JB Delft, Netherlands
关键词
Magnetic material; Heat pump; Irreversibility; Optimal performance; THERMOECONOMIC OPTIMIZATION; REFRIGERATOR;
D O I
10.1016/j.physb.2010.11.067
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
Taking into account the finite-rate heat transfer in the heat-transfer processes, heat leak between the two external heat reservoirs, regenerative loss, regeneration time, and internal irreversibility due to dissipation of the cycle working substance, an irreversible magnetic Ericsson heat-pump cycle is presented. On the basis of the thermodynamic properties of magnetic materials, the performance characteristics of the irreversible magnetic Ericsson heat-pump are investigated and the relationship between the optimal heating load and the coefficient of performance (COP) is derived. Moreover, the maximum heating load and the corresponding COP as well as the maximum COP and the corresponding heating load are obtained. Furthermore, the other optimal performance characteristics are discussed in detail. The results obtained here may provide some new information for the optimal parameter design and the development of real magnetic Ericsson heat-pumps. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:633 / 639
页数:7
相关论文
共 32 条
[1]   Magnetocaloric heat-pump cycles based on the AF-F transition in Fe-Rh alloys [J].
Annaorazov, MP ;
Ünal, M ;
Nikitin, SA ;
Tyurin, AL ;
Asatryan, KA .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2002, 251 (01) :61-73
[2]  
[Anonymous], INT J AMBIENT ENERGY
[3]  
[Anonymous], 1972, Statistical mechanics
[4]   THERMODYNAMIC ANALYSIS OF 4 MAGNETIC HEAT-PUMP CYCLES [J].
CHEN, FC ;
MURPHY, RW ;
MEI, VC ;
CHEN, GL .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1992, 114 (04) :715-720
[5]   ANALYSIS OF TERBIUM THERMODYNAMIC CHARACTERISTICS FOR MAGNETIC HEAT-PUMP APPLICATIONS [J].
CHEN, GL ;
MEI, VC ;
CHEN, FC .
JOURNAL OF APPLIED PHYSICS, 1992, 72 (09) :3908-3911
[6]   Minimum power input of irreversible stirling refrigerator for given cooling rate [J].
Chen, JC .
ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (12) :1255-1263
[7]   Irreversible absorption heat-pump and its optimal performance [J].
Chen, LG ;
Qin, XY ;
Sun, FR ;
Wu, C .
APPLIED ENERGY, 2005, 81 (01) :55-71
[8]   LOCAL ENTROPY GENERATION ANALYSIS OF A ROTARY MAGNETIC HEAT-PUMP REGENERATOR [J].
DROST, MK ;
WHITE, MD .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1994, 116 (02) :140-147
[9]   Heat-transfer effect on the performance of a magnetic Ericsson refrigerator [J].
He, JX ;
Chen, JC ;
Wu, C .
JOURNAL OF NON-EQUILIBRIUM THERMODYNAMICS, 2002, 27 (01) :57-69
[10]   Performance evaluation of irreversible Stirling and Ericsson heat pump cycles [J].
Kaushik, SC ;
Tyagi, SK ;
Bose, SK ;
Singhal, MK .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (02) :193-200