Consistency Condition and ML-EM Checkerboard Artifacts

被引:0
|
作者
You, Jiangsheng [1 ,2 ]
Wang, Jing [2 ,3 ]
Liang, Zhengrong [2 ,4 ]
机构
[1] Cubic Imaging LLC, 264 Grove St, Auburndale, MA 02466 USA
[2] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[3] SUNY Stony Brook, Dept Phys & Astron, Stony Brook, NY 11794 USA
[4] SUNY Stony Brook, Dept Comp Sci, Stony Brook, NY 11794 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The expectation maximization (EM) algorithm for the maximum likelihood (ML) image reconstruction criterion generates severe checkerboard artifacts in the presence of noise. A classical remedy is to impose an a priori constraint for a penalized ML or maximum a posteriori probability solution. The penalty reduces the checkerboard artifacts and also introduces uncertainty because a priori information is usually unknown in clinic. Recent theoretical investigation reveals that the noise can be divided into two components. One is called null-space noise which annihilates during filtered backprojection (FBP)-type analytical image reconstruction. The other is called range-space noise which propagates into the FBP-type analytically reconstructed image. In particular, the null-space noise can be numerically estimated. The aim of this work is to investigate the relation between the null-space noise and the checkerboard artifacts in the ML-EM image reconstruction from noise projection data. It is expected that removing the null-space noise from the projection data could improve the signal-to-noise ratio of the data and, therefore, reduce the checkerboard artifacts in the ML-EM reconstructed images. The expectation was realized by computer simulation studies with application to single photon emission computed tomography, where the noise has been a major factor for image degradation. The reduction of the ML-EM checkerboard artifacts by removing the null-space noise avoids the uncertainty of using a priori penalty.
引用
收藏
页码:2245 / 2250
页数:6
相关论文
共 50 条
  • [31] ML-EM based dual tracer PET image reconstruction with inclusion of prompt gamma attenuation
    Pfaehler, Elisabeth
    Niekaemper, Debora
    Scheins, Juergen
    Shah, N. Jon
    Lerche, Christoph W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (01):
  • [32] Temperature distribution measurement based on ML-EM method using enclosed acoustic CT system
    1600, International Frequency Sensor Association, 46 Thorny Vineway, Toronto, ON M2J 4J2, Canada (150):
  • [33] Limited-angular-view ML-EM pinhole SPECT for breast tumor detection.
    Li, J
    Scarfone, C
    Jaszczak, RJ
    Wang, H
    Coleman, RE
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 971 - 971
  • [34] NOISE PROPERTIES OF FILTERED-BACKPROJECTION AND ML-EM RECONSTRUCTED EMISSION TOMOGRAPHIC-IMAGES
    WILSON, DW
    TSUI, BMW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1198 - 1203
  • [35] Semi-analytical response function for ML-EM deconvolution of NaI detector energy spectra
    Engdahl, John C.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1346 - 1350
  • [36] A hybrid ML-EM algorithm for calculation of maximum likelihood estimates in semiparametric shared frailty models
    Vu, HTV
    Knuiman, MW
    COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2002, 40 (01) : 173 - 187
  • [37] A tailored ML-EM algorithm for reconstruction of truncated projection data using few view angles
    Mao, Yanfei
    Zeng, Gengsheng L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (12): : N157 - N169
  • [38] Application of the ML-EM algorithm in the suppression of Compton background of gamma-ray spectroscopy system
    Sy Minh Tuan Hoang
    Gwang Min Sun
    Hani Baek
    Jiseok Kim
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 2137 - 2146
  • [39] ML-EM Reconstruction Model including Total Variation for Low Dose PET High Resolution Data
    Chavez-Rivera, Lucia B.
    Ortega-Maynez, Leticia
    Mejia, Jose
    Mederos, Boris
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [40] Extension of the ML-EM algorithm for dose estimation using PET in proton therapy: application to an inhomogeneous target
    Masuda, Takamitsu
    Nishio, Teiji
    Sano, Akira
    Karasawa, Kumiko
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (18):