Phase-Locked Loop Research of Grid-Connected Inverter Based on Impedance Analysis

被引:12
作者
Jiang, Yuxia [1 ]
Li, Yonggang [1 ]
Tian, Yanjun [1 ]
Wang, Luo [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Baoding 071003, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
LCL-type grid-connected inverter; DSOGI-PLL; impedance analysis; system stability; PLL;
D O I
10.3390/en11113077
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to improve the phenomenon that a traditional phase-locked loop based on a double second-order generalized integrator (DSOGI-PLL) cannot track signal amplitude and phase accurately when the input signal contains DC components and high-order harmonics, the structure of a second-order generalized integrator-quadrature signals generator (SOGI-QSG) is modified. The paper establishes the impedance model considering the DSOGI-PLL structure of the inductor-capacitor-inductor-type (LCL-type) inverter grid-connected system adopting current control measured from the grid terminal in alternating current side, introducing voltage feedback control to enhance the stability of the system. Meanwhile, analyzing the influence of parameters on impedance according to the impedance model established preferable design parameters. The improvement in SOGI-QSG structure is good for PLL to lock the grid voltage phase more accurately and the retrofitting in control strategy based on the impedance is able to uplift the inverter output impedance phase which is conducive to system stability by increasing the phase margin of the system. The simulation in Matlab/Simulink is carried out to verify the effectiveness of the proposed control strategy.
引用
收藏
页数:21
相关论文
共 25 条
  • [1] Bose BK, 2017, P IEEE, V105, P2011, DOI 10.1109/JPROC.2017.2745621
  • [2] [陈新 Chen Xin], 2014, [中国电机工程学报, Proceedings of the Chinese Society of Electrical Engineering], V34, P4559
  • [3] Du Y., 2017, P IEEE EN CONV C EXP
  • [4] A New Hybrid PLL for Interconnecting Renewable Energy Systems to the Grid
    Hadjidemetriou, Lenos
    Kyriakides, Elias
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (06) : 2709 - 2719
  • [5] An Efficient Hybrid Filter-Based Phase-Locked Loop under Adverse Grid Conditions
    Hui, Nanmu
    Wang, Dazhi
    Li, Yunlu
    [J]. ENERGIES, 2018, 11 (04)
  • [6] Jin L., 2015, P IEEE 10 C IND EL A
  • [7] On Small Signal Frequency Stability under Virtual Inertia and the Role of PLLs
    Khan, Sohail
    Bletterie, Benoit
    Anta, Adolfo
    Gawlik, Wolfgang
    [J]. ENERGIES, 2018, 11 (09)
  • [8] Stability Analysis of LCL-Type Grid-Connected Inverter Under Single-Loop Inverter-Side Current Control With Capacitor Voltage Feedforward
    Liu, Bangyin
    Wei, Qikang
    Zou, Changyue
    Duan, Shanxu
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2018, 14 (02) : 691 - 702
  • [9] A Three-Phase PLL Algorithm Based on Signal Reforming Under Distorted Grid Conditions
    Liu, Baoquan
    Zhuo, Fang
    Zhu, Yixin
    Yi, Hao
    Wang, Feng
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) : 5272 - 5283
  • [10] Output Impedance Modeling and Stability Prediction of Three-Phase Paralleled Inverters With Master-Slave Sharing Scheme Based on Terminal Characteristics of Individual Inverters
    Liu, Zeng
    Liu, Jinjun
    Hou, Xueyu
    Dou, Qingyun
    Xue, Danhong
    Liu, Teng
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (07) : 5306 - 5320