Electrochemical Determination of Fenitrothion Organophosphorus Pesticide Using Polyzincon Modified-glassy Carbon Electrode

被引:27
|
作者
Ensafi, Ali Aasghar [1 ]
Rezaloo, Fatemeh [1 ]
Rezaei, Behzad [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Electrochemical sensor; Organophosphate pesticides; Fenitrothion; Poly-zincon; REDUCED GRAPHENE OXIDE; METHYL-PARATHION; EXTRACTION; SAMPLES; SENSOR; WATER; BIOSENSOR; FIBER; ASSAY;
D O I
10.1002/elan.201700406
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a glassy carbon electrode (GCE) was modified with polyzincon. The modified electrode was used as a simple, inexpensive and highly sensitive electrochemical sensor for the determination of organophosphorus pesticide fenitrothion. To fabricate the electrochemical sensor, GCE was immersed in 0.10mmolL(-1) zincon solutions at pH7.0 and then successively scanned between -1.00 to 2.20V (vs. Ag/AgCl) at a scan rate of 70mVs(-1) for six cycles. The morphology and structure of the polyzincon were studied with atomic force microscopy and scanning electron microscopy. A comparison of the electrochemical behavior of fenitrothion on the unmodified and polyzincon modified-GCE showed that in the modified electrode not only the oxidation peak current increased, but also the overpotential shifted to lower one. The experimental conditions such as sample solution pH, accumulation potential, and time were optimized. The differential pulse voltammetric responses of fenitrothion at potential about -0.60V was used for the determination of fenitrothion. The peak current increased with increasing the concentration of fenitrothion in the range of 5 to 8600nmolL(-1) with a detection limit of 1.5nmolL(-1). Finally, the electrochemical sensor was used for the analysis of fenitrothion in water and fruit samples.
引用
收藏
页码:2839 / 2846
页数:8
相关论文
共 50 条
  • [1] Electrochemical detection of fenitrothion usingnanosilver/dodecane modified glassy carbon electrode
    Kumaravel, A.
    Murugananthan, M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 331
  • [2] Electrochemical study of fenitrothion and bifenox and their simultaneous determination using multiwalled carbon nanotube modified glassy carbon electrode
    Salehzadeh, Hamid
    Ebrahimi, Mohsen
    Nematollahi, Davood
    Salarian, Amir Ahmad
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 767 : 188 - 194
  • [3] An Electrochemical Sensor Based on Electropolymerization of β-Cyclodextrin on Glassy Carbon Electrode for the Determination of Fenitrothion
    Wang, Rong
    Wang, Shulong
    Qin, Caihong
    Nie, Qiyang
    Luo, Yougang
    Qin, Qi-Pin
    Wang, Ruijuan
    Liu, Baiquan
    Luo, Dongxiang
    SENSORS, 2023, 23 (01)
  • [4] Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode
    Tefera, M.
    Tessema, M.
    Admassie, S.
    Mehretie, S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2015, 2 (02): : 139 - 150
  • [5] Electrochemical determination of caffeine in beverage using graphene oxide modified glassy carbon electrode
    Murugan, E.
    Poongan, A.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2021, 28 (05) : 528 - 536
  • [6] A Selective Electrochemical Sensor Based on a Modified-Glassy Carbon Electrode Using f-MWCNTs-Polydopamine for Ciprofloxacin Detection
    Sabeti, M.
    Ensafi, Ali A.
    Mousaabadi, K. Zarean
    Rezaei, B.
    IEEE SENSORS JOURNAL, 2021, 21 (18) : 19714 - 19721
  • [7] Voltammetric Determination of Immunosuppressive Agent, Azathioprine, by Using a Graphene-Chitosan Modified-Glassy Carbon Electrode
    Hatami, Zahra
    Jalali, Fahimeh
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2015, 51 (01) : 70 - 76
  • [8] A highly sensitive and selective electrochemical sensor based on polythiourea modified glassy carbon electrode for detecting fenitrothion in vegetables
    Yihun, Tihunie Fentahun
    Aragaw, Belete Asefa
    Tsegaye, Abebaw Adgo
    Tefera, Molla
    Ambo, Melaku Metto
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2024, 19 (10):
  • [9] Electrochemical Determination of Levofloxacin Using Poly(Pyrogallol Red) Modified Glassy Carbon Electrode
    Kocak, Cagri Ceylan
    Aslisen, Burak
    Karabiberoglu, Sukriye
    Ozdokur, Kemal Volkan
    Aslan, Avni
    Kocak, Suleyman
    CHEMISTRYSELECT, 2022, 7 (41):
  • [10] Poly (safranine) modified carbon paste electrode as a sensor for the determination of fenitrothion pesticide
    El-Hallag, Ibrahim Shibl
    Moharram, Youssef Ibrahim
    Selim, Sameh Mahmoud
    SCIENTIFIC REPORTS, 2023, 13 (01)