Nanomaterials-based electrochemical sensors and biosensors for the detection of non-steroidal anti-inflammatory drugs

被引:69
作者
Kalambate, Pramod K. [1 ,2 ]
Noiphung, Julaluk [1 ,2 ]
Rodthongkum, Nadnudda [3 ,4 ]
Larpant, Nutcha [1 ,2 ]
Thirabowonkitphithan, Pannawich [5 ]
Rojanarata, Theerasak [6 ]
Hasan, Mohammed [7 ]
Huang, Yunhui [8 ]
Laiwattanapaisal, Wanida [1 ,2 ]
机构
[1] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Clin Chem, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Clin Chem, Biosensors & Bioanalyt Technol Cells & Innovat Te, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Met & Mat Sci Res Inst, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Ctr Excellence Respons Wearable Mat, Bangkok 10330, Thailand
[5] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Clin Chem, Grad Program Clin Biochem & Mol Med, Bangkok 10330, Thailand
[6] Silpakorn Univ, Fac Pharm, Dept Pharmaceut Chem, Nakhon Pathom 73000, Thailand
[7] Univ Mumbai, Dept Chem, Mumbai 400098, Maharashtra, India
[8] Huazhong Univ Sci & Technol, State Key Lab Mat Proc & Die & Mould Technol, Sch Mat Sci & Engn, Wuhan 430074, Hubei, Peoples R China
关键词
NSAIDs; Nanomaterials; MXenes; Electrochemical sensors; Biosensors; Environmental analysis; Pharmaceutical analysis; Biological sample analysis; REDUCED GRAPHENE OXIDE; CARBON-PASTE ELECTRODE; SIMULTANEOUS VOLTAMMETRIC DETERMINATION; DOPED TIO2 NANOPARTICLES; MEFENAMIC-ACID; ACETYLSALICYLIC-ACID; GOLD-NANOPARTICLES; FLUFENAMIC ACID; ASCORBIC-ACID; BIOELECTROCHEMICAL SENSOR;
D O I
10.1016/j.trac.2021.116403
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-steroidal anti-inflammatory drugs (NSAIDs) are the most frequently administered over-the-counter medicines to treat fever, pain and control inflammation. However, their overdose can cause detrimental effects in the human body, whereas uncontrollable disposable into ecosystems pose significant environmental concerns. Electrochemical (bio) sensors overcome the limitations of traditional detection approaches and provide immense potential for sensitive, selective, efficient, and low-cost detection of pharmaceuticals in complex media. This review presents an overview of the current state-of-the-art progress in electrochemical (bio) sensors utilizing nanoscale materials (e.g., metal/metal oxides nanoparticles, carbonaceous materials, and conducting polymers) as electrode modifiers that target NSAIDs. Special attention is paid to different electrode fabrication strategies, sensor/analyte interactions, and analysis of real-world samples. Besides, experimental conditions and some analytical parameters including linear concentration range, detection limit, detection method, etc., are compiled and compared. Finally, this review concludes by discussing future prospects, challenges, and possibilities in designing next-generation advanced sensing devices. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:28
相关论文
共 137 条
  • [1] Gold nanoparticle/multi-walled carbon nanotube modified glassy carbon electrode as a sensitive voltammetric sensor for the determination of diclofenac sodium
    Aflhami, Abbas
    Bahiraei, Atousa
    Madrakian, Tayyebeh
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 59 : 168 - 176
  • [2] Artificial neural network for the voltamperometric quantification of diclofenac in presence of other nonsteroidal anti-inflammatory drugs and some commercial excipients
    Aguilar-Lira, G. Y.
    Gutierrez-Salgado, J. M.
    Rojas-Hernandez, A.
    Rodriguez-Avila, J. A.
    Paez-Hernandez, M. E.
    Alvarez-Romero, G. A.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 801 : 527 - 535
  • [3] New insights on diclofenac electrochemistry using graphite as working electrode
    Aguilar-Lira, G. Y.
    Alvarez-Romero, G. A.
    Zamora-Suarez, A.
    Palomar-Pardave, M.
    Rojas-Hernandez, A.
    Rodriguez-Avila, J. A.
    Paez-Hernandez, M. E.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 794 : 182 - 188
  • [4] Electrochemical Determination of Celecoxib on a Graphene Based Carbon Ionic Liquid Electrode Modified with Gold Nanoparticles and Its Application to Pharmaceutical Analysis
    Arkan, Elham
    Karimi, Ziba
    Shamsipur, Mojtaba
    Saber, Reza
    [J]. ANALYTICAL SCIENCES, 2013, 29 (08) : 855 - 860
  • [5] New Insight in Fabrication of a Sensitive Nano-Magnetite/Glutamine/Carbon Based Electrochemical Sensor for Determination of Aspirin and Omeprazole
    Atta, Nada F.
    Galal, Ahmed
    El-Ads, Ekram H.
    Galal, Aya E.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (02) : B161 - B172
  • [6] Aptamer-based sensor for diclofenac quantification using carbon nanotubes and graphene oxide decorated with magnetic nanomaterials
    Azadbakht, Azadeh
    Derikvandi, Zeinab
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2018, 15 (03) : 595 - 606
  • [7] Encapsulation of NSAIDs for inflammation management: Overview, progress, challenges and prospects
    Badri, Waisudin
    Miladi, Karim
    Nazari, Qand Agha
    Greige-Gerges, Helene
    Fessi, Hatem
    Elaissari, Abdelhamid
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2016, 515 (1-2) : 757 - 773
  • [8] Ultrasound-accelerated synthesis of gold nanoparticles modified choline chloride functionalized graphene oxide as a novel sensitive bioelectrochemical sensor: Optimized meloxicam detection using CCD-RSM design and application for human plasma sample
    Bahrani, Sonia
    Razmi, Zahra
    Ghaedi, Mehrorang
    Asfaram, Arash
    Javadian, Hamedreza
    [J]. ULTRASONICS SONOCHEMISTRY, 2018, 42 : 776 - 786
  • [9] Continuous monitoring of Naproxen by a cytochrome P450-based electrochemical sensor
    Baj-Rossi, C.
    Jost, T. Rezzonico
    Cavallini, A.
    Grassi, F.
    De Micheli, G.
    Carrara, S.
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 53 : 283 - 287
  • [10] Plasma-induced enhancement of UV photoluminescence in ZnO nanowires
    Baratto, Camilla
    Comini, Elisabetta
    Ferroni, Matteo
    Faglia, Guido
    Sberveglieri, Giorgio
    [J]. CRYSTENGCOMM, 2013, 15 (39): : 7981 - 7986