Thermal-Fatigue Analysis of District-Heating Pipelines in China

被引:3
|
作者
Jing, Shenglan [1 ]
Zan, Zhuoyu [1 ]
Song, Chongfang [1 ]
Zhang, Jianwei [2 ]
Lei, Yonggang [1 ]
Wang, Fei [1 ]
Li, Xinyi [3 ]
机构
[1] Taiyuan Univ Technol, Dept Bldg Environm & Energy Engn, Taiyuan 030024, Shanxi, Peoples R China
[2] Taiyuan Dist Heating Grp, 48 West Kangle St, Taiyuan 030012, Shanxi, Peoples R China
[3] Univ Sheffield, Dept Civil & Struct Engn, Sheffield S1 3JD, S Yorkshire, England
关键词
District-heating pipelines; Thermal fatigue; Rain-flow algorithm; China;
D O I
10.1061/(ASCE)PS.1949-1204.0000451
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The temperature variation of the district heating (DH) pipelines during the operation is the most severe threat to the lifetime of the systems. The number of cycles used in the fatigue analysis in the European standard were based on the lEA projects, and there were no sufficient studies conducted in China. This paper aims to make reasonable estimations of the maximum number of temperature load cycles for DH pipelines in China. Based on the data, the rain flow cycle-counting algorithms were applied to calculate the number of full temperature cycles. The regression models of design lines between full temperature cycles and temperature variations were established. The maximum values for supply pipelines and return pipelines were obtained by using the design lines. The equivalent full action cycles (b=4 and Delta Tref=110 degrees C) are about 200 cycles for supply pipelines and 136 cycles for return pipelines which are both less than 250 cycles recommended in the European standard. Using 200 for the supply pipelines and 136 for the return pipelines, the stress limits could increase from 707 to 750 MPa and from 707 to 823 MPa respectively.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] The reduction of friction losses in district-heating pipelines
    Krope, A
    Krope, J
    Ticar, I
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2000, 46 (08): : 525 - 531
  • [2] THERMAL DESIGN OF DISTRICT-HEATING DISTRIBUTION NETWORKS
    NEALE, AJ
    BABUSHAQ, RF
    PROBERT, SD
    SHILSTON, MJ
    APPLIED ENERGY, 1987, 28 (04) : 269 - 282
  • [3] Thermal Fatigue Analysis of the Secondary Network of District Heating Systems in China
    Zan, Zhuoyu
    Song, Chongfang
    Jing, Shenglan
    Zhang, Jianwei
    Lei, Yonggang
    Wang, Fei
    JOURNAL OF PIPELINE SYSTEMS ENGINEERING AND PRACTICE, 2020, 11 (03)
  • [4] PRE-INSULATED DISTRICT-HEATING PIPELINES - DESIGN AND OPERATIONAL ADVICE
    WONSYLD, T
    BABUSHAQ, RF
    PROBERT, SD
    APPLIED ENERGY, 1992, 42 (04) : 227 - 236
  • [5] FINITE-DIFFERENCE TECHNIQUE FOR OPTIMIZING THE LOCATIONS OF DISTRICT-HEATING PIPELINES
    BABUSHAO, RF
    GEORGE, HE
    OCALLAGHAN, PW
    PROBERT, SD
    HEAT RECOVERY SYSTEMS & CHP, 1990, 10 (03): : 277 - 284
  • [6] CONTRIBUTION TO THE THERMAL DESIGN OF NUCLEAR DISTRICT-HEATING PLANTS
    BORDIHN, S
    LUTZOW, K
    KERNENERGIE, 1986, 29 (08): : 307 - 311
  • [7] Sparse district-heating in Sweden
    Nilsson, Stefan Forsaeus
    Reidhav, Charlotte
    Lygnerud, Kristina
    Werner, Sven
    APPLIED ENERGY, 2008, 85 (07) : 555 - 564
  • [8] Regulation of district-heating systems
    Wissner, Matthias
    UTILITIES POLICY, 2014, 31 : 63 - 73
  • [9] BIOMASS AND DISTRICT-HEATING SYSTEMS
    GUSTAVSSON, L
    RENEWABLE ENERGY, 1994, 5 (5-8) : 838 - 840
  • [10] THERMAL-FATIGUE ANALYSIS APPLIED TO TURBINE AIRFOILS
    VOGEL, WH
    WARING, DB
    SPAETH, CE
    MARTENS, WR
    DONACHIE, MJ
    MECHANICAL ENGINEERING, 1965, 87 (05) : 138 - &