Risk factors for atrial fibrillation recurrence after cryoballoon catheter ablation in patients with paroxysmal atrial fibrillation

被引:0
|
作者
Zhou, Jin [1 ,2 ]
Xu, Jing [2 ]
Sun, Shan [2 ]
Cheng, Aijuan [2 ]
Li, Peng [2 ]
Ding, Jun [2 ]
Yang, Peigen [2 ]
Zhang, Zhiyuan [2 ]
Fang, Tao [2 ]
Yan, Yingchuan [2 ]
Cong, Hongliang [1 ,2 ]
机构
[1] Tianjin Med Univ, Tianjin, Peoples R China
[2] Tianjin Chest Hosp, Dept Cardiol, 261 South Taierzhuang Rd, Tianjin 300200, Peoples R China
关键词
Atrial fibrillation recurrence; cryoballoon catheter ablation; paroxysmal atrial fibrillation; multivariate logistic regression; risk factor; C-REACTIVE PROTEIN; FOLLOW-UP; INFLAMMATION; PREDICTORS;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: This retrospective study aimed to analyze the risk factors for post-surgical atrial fibrillation (AF) recurrence in paroxysmal AF patients who underwent cryoballoon catheter ablation. Methods: We selected a total of 98 patients with paroxysmal AF who were treated with frozen balloon catheter ablation in Tianjin Chest Hospital from January to December in 2016. A three-dimensional (3-D) electroanatomical mapping system was used to guide the cryoballoon catheter ablation surgery. According to whether the AF recurred during postoperative follow-up (starting from 3 months after surgery), the patients were divided into AF recurrence group and sinus rhythm maintenance group. Risk factors for AF recurrence were analyzed by both univariate and multivariate logistic regression model. Results: Of the 98 patients, 17 were in AF recurrence group and 81 were in sinus rhythm maintenance group. Univariate analysis showed that there was significant difference between two groups in the incidence of coronary heart disease, the level of hypersensitive C-reactive protein, B-type natriuretic peptide precursor and the duration of AF (all P < 0.05). Multivariate logistic regression analysis identified hypersensitive C-reactive protein, type B natriuretic peptide and AF duration as the factors influencing the recurrence of AF (all P < 0.05). Conclusion: The concentration of hypersensitive C-reactive protein, B-type natriuretic peptide and the duration of AF are independent risk factors for postoperative AF recurrence in paroxysmal AF patients who undergo cryoballoon catheter ablation.
引用
收藏
页码:11205 / 11210
页数:6
相关论文
共 50 条
  • [31] Catheter ablation of paroxysmal atrial fibrillation
    Sacher, F
    Jaïs, P
    Hocini, M
    Reuter, S
    Bordachar, P
    Garrigue, S
    Haïssaguerre, M
    Clémenty, J
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2004, 97 (10): : 949 - 956
  • [32] Catheter Ablation for Paroxysmal Atrial Fibrillation
    Stevenson, William G.
    Albert, Christine M.
    NEW ENGLAND JOURNAL OF MEDICINE, 2012, 367 (17): : 1648 - 1649
  • [33] Protracted impairment of left atrial compliance after cryoballoon ablation in recurrence-free patients with paroxysmal atrial fibrillation
    Minamisaka, Tomoko
    Tachibana, Koichi
    Shinoda, Yukinori
    Fukuoka, Hidetada
    Inui, Hirooki
    Ueno, Keisuke
    Inoue, Soki
    Mine, Kentaro
    Ueda, Kumpei
    Hoshida, Shiro
    AMERICAN JOURNAL OF CARDIOVASCULAR DISEASE, 2020, 10 (04): : 514 - 521
  • [34] Association of the Time Between First Diagnosis of Atrial Fibrillation and Cryoballoon Ablation Correlate with Recurrence of Paroxysmal Atrial Fibrillation
    Ekizler, Firdevs Aysenur
    Senturk, Bihter
    Acar, Burak
    Ozeke, Ozcan
    Dogan, Pinar
    Turak, Osman
    Ozcan, Firat
    Topaloglu, Serkan
    Aras, Dursun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : C221 - C221
  • [35] Retraction Note: The efficacy and safety of cryoballoon catheter ablation in patients with paroxysmal atrial fibrillation
    Adil K. Baimbetov
    Kuat B. Abzaliev
    Aiman M. Jukenova
    Kenzhebek A. Bizhanov
    Binali A. Bairamov
    Aliya Ye. Ualiyeva
    Irish Journal of Medical Science (1971 -), 2024, 193 : 539 - 539
  • [36] RETRACTED ARTICLE: The efficacy and safety of cryoballoon catheter ablation in patients with paroxysmal atrial fibrillation
    Adil K. Baimbetov
    Kuat B. Abzaliev
    Aiman M. Jukenova
    Kenzhebek A. Bizhanov
    Binali A. Bairamov
    Aliya Ye. Ualiyeva
    Irish Journal of Medical Science (1971 -), 2022, 191 : 187 - 193
  • [37] Cryoballoon Ablation in Young Patients With Lone Paroxysmal Atrial Fibrillation
    Wojcik, Maciej
    Berkowitsch, Alexander
    Zaltsberg, Sergey
    Hamm, Christian W.
    Pitschner, Heinz F.
    Neumann, Thomas
    Kuniss, Malte
    REVISTA ESPANOLA DE CARDIOLOGIA, 2014, 67 (07): : 558 - 563
  • [38] The impact of height on recurrence after index catheter ablation of paroxysmal atrial fibrillation
    Ching-Han Liu
    Li-Wei Lo
    Fa-Po Chung
    Shih-Lin Chang
    Yu-Feng Hu
    Yenn-Jiang Lin
    Shih-Chung Huang
    Su-Ting Gan
    Chin-Yu Lin
    Tze-Fan Chao
    Jo-Nan Liao
    Ta-Chuan Tuan
    Chih-Min Liu
    Yang-Che Shiu
    Cheng-I Wu
    Ling Kuo
    Jennifer Jeanne B. Vicera
    Isaiah Lugtu
    Cheng-Hung Li
    Yu-Cheng Hsieh
    Yi-Jen Chen
    Shih-Ann Chen
    Journal of Interventional Cardiac Electrophysiology, 2022, 64 : 587 - 595
  • [39] Risk factors for late recurrence in patients with nonvalvular atrial fibrillation after radiofrequency catheter ablation
    Peng, Zhang
    Wen-Heng, Liu
    Qing, Zhao
    Pin, Sun
    Shang-Lang, Cai
    Mao-Jing, Wang
    Ya-Qi, Pan
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2022, 27 (02)
  • [40] The impact of height on recurrence after index catheter ablation of paroxysmal atrial fibrillation
    Liu, Ching-Han
    Lo, Li-Wei
    Chung, Fa-Po
    Chang, Shih-Lin
    Hu, Yu-Feng
    Lin, Yenn-Jiang
    Huang, Shih-Chung
    Gan, Su-Ting
    Lin, Chin-Yu
    Chao, Tze-Fan
    Liao, Jo-Nan
    Tuan, Ta-Chuan
    Liu, Chih-Min
    Shiu, Yang-Che
    Wu, Cheng-, I
    Kuo, Ling
    Vicera, Jennifer Jeanne B.
    Lugtu, Isaiah
    Li, Cheng-Hung
    Hsieh, Yu-Cheng
    Chen, Yi-Jen
    Chen, Shih-Ann
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 64 (03) : 587 - 595