Compact mid-infrared trace gas sensor based on difference-frequency generation of two diode lasers in periodically poled LiNbO3

被引:74
作者
Richter, D
Lancaster, DG
Curl, RF
Neu, W
Tittel, FK
机构
[1] Rice Univ, Rice Quantum Inst, Houston, TX 77005 USA
[2] Univ Appl Sci, Fachhsch Ostfriesland, D-26723 Emden, Germany
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 1998年 / 67卷 / 03期
关键词
PACS: 7.65; 42.60B; 42.80;
D O I
10.1007/s003400050514
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The development and characterization of a compact mid-infrared source for high-resolution spectroscopic detection of trace gases such as methane and water vapor at 3.3 mu m in ambient air is reported. This source utilizes difference frequency generation (DFG) in a periodically poled LiNbO3 (PPLN) crystal pumped by two single-frequency diode lasers. A maximum DFG power of 1.6 mu W at 3.6 mu m was generated with a pump power of 61.4 mW at 832 nm and a signal power of 41.5 mW at 1083 nm incident on a 19-mm-long PPLN crystal, which corresponds to a conversion efficiency of 335 mu WW-2 cm(-1).
引用
收藏
页码:347 / 350
页数:4
相关论文
共 17 条
  • [1] CANARELLI P, 1992, J OPT SOC AM B, V9, P2
  • [2] GOLDBERG L, 1995, OPT LETT, V20, P11
  • [3] JUNDT DH, 1997, OPT LETT, V22, P20
  • [4] Real-time measurements of trace gases using a compact difference-frequency-based sensor operating at 3.5 μm
    Lancaster, DG
    Richter, D
    Curl, RF
    Tittel, FK
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 67 (03): : 339 - 345
  • [5] Fibre coupled difference frequency generation utilising ytterbium-doped fibre amplifier and periodically poled LiNbO3
    Lancaster, DG
    Goldberg, L
    Koplow, J
    Curl, RF
    Tittel, FK
    [J]. ELECTRONICS LETTERS, 1998, 34 (13) : 1345 - 1347
  • [6] MYERS LE, 1996, OPT LETT, V21, P8
  • [7] *ONT CORP, HITRAN 96
  • [8] POWERS PE, 1998, OPT LETT, V23, P3
  • [9] PUTNAM RS, 1998, IN PRESS APPL OPT
  • [10] SCHADE W, 1996, APPL PHYS B, V63, P1