Clinical accuracy of the MedGemt indirect calorimeter for measuring resting energy expenditure in cancer patients

被引:42
|
作者
Reeves, MM
Capra, S
Bauer, J
Davies, PSW
Battistutta, D
机构
[1] Queensland Univ Technol, Ctr Hlth Res, Brisbane, Qld, Australia
[2] Wesley Res Inst, Brisbane, Qld, Australia
[3] Univ Newcastle, Australian Ctr Evidence Based Nutr & Dietet, Newcastle, NSW 2308, Australia
[4] Univ Queensland, Royal Childrens Hosp, Childrens Nutr Res Ctr, Brisbane, Qld, Australia
关键词
REE; oxygen consumption; metabolic rate; cancer; nutrition support;
D O I
10.1038/sj.ejcn.1602114
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: To compare, in patients with cancer and in healthy subjects, measured resting energy expenditure (REE) from traditional indirect calorimetry to a new portable device (MedGem(TM)) and predicted REE. Design: Cross-sectional clinical validation study. Setting: Private radiation oncology centre, Brisbane, Australia. Subjects: Cancer patients (n=18) and healthy subjects (n=17) aged 37-86y, with body mass indices ranging from 18 to 42 kg/m(2). Interventions: Oxygen consumption (VO2) and REE were measured by VMax229 (VM) and MedGem (MG) indirect calorimeters in random order after a 12-h fast and 30-min rest. REE was also calculated from the MG without adjustment for nitrogen excretion (MGN) and estimated from Harris-Benedict prediction equations. Data were analysed using the Bland and Altman approach, based on a clinically acceptable difference between methods of 5%. Results: The mean bias (MGN-VM) was 10% and limits of agreement were -42 to 21% for cancer patients; mean bias -5% with limits of -45 to 35% for healthy subjects. Less than half of the cancer patients (n=7, 46.7%) and only a third (n=5, 33.3%) of healthy subjects had measured REE by MGN within clinically acceptable limits of VM. Predicted REE showed a mean bias (HB-VM) of -5% for cancer patients and 4% for healthy subjects, with limits of agreement of -30 to 20% and -27 to 34%, respectively. Conclusions: Limits of agreement for the MG and Harris Benedict equations compared to traditional indirect calorimetry were similar but wide, indicating poor clinical accuracy for determining the REE of individual cancer patients and healthy subjects.
引用
收藏
页码:603 / 610
页数:8
相关论文
共 50 条
  • [21] A novel equation synthesis for estimating resting energy expenditure in prostate cancer patients
    Tek, Nilufer Acar
    Kocak, Tevfik
    Yesil, Suleyman
    Sozen, Tevfik Sinan
    BMC UROLOGY, 2025, 25 (01):
  • [22] Comparison of the Beacon and Quark indirect calorimetry devices to measure resting energy expenditure in ventilated ICU patients
    Slingerland-Boot, H.
    Adhikari, S.
    Mensink, M. R.
    van Zanten, A. R. H.
    CLINICAL NUTRITION ESPEN, 2022, 48 : 370 - 377
  • [23] Resting energy expenditure in head and neck cancer patients before and during radiotherapy
    Langius, Jacqueline A. E.
    Kruizenga, Hinke M.
    Uitdehaag, Bernard M. J.
    Langendijk, Johannes A.
    Doornaert, Patricia
    Leemans, C. Rene
    Weijs, Peter J. M.
    CLINICAL NUTRITION, 2012, 31 (04) : 549 - 554
  • [24] Measuring energy expenditure in Gottingen Minipigs using indirect calorimetry: validation and methodological considerations
    Bredum, Simon K.
    Jacobsen, Julie
    Cirera, Susanna
    Christoffersen, Berit o.
    LABORATORY ANIMAL RESEARCH, 2025, 41 (01)
  • [25] Accuracy of Prediction Formulae for the Assessment of Resting Energy Expenditure in Hospitalized Children
    Agostoni, Carlo
    Edefonti, Alberto
    Calderini, Edoardo
    Fossali, Emilio
    Colombo, Carla
    Battezzati, Alberto
    Bertoli, Simona
    Milani, Gregorio
    Bisogno, Arianna
    Perrone, Michela
    Bettocchi, Silvia
    De Cosmi, Valentina
    Mazzocchi, Alessandra
    Bedogni, Giorgio
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2016, 63 (06) : 708 - 712
  • [26] Validity of resting energy expenditure estimated by an activity monitor compared to indirect calorimetry
    Dellava, Jocilyn E.
    Hoffman, Daniel J.
    BRITISH JOURNAL OF NUTRITION, 2009, 102 (01) : 155 - 159
  • [27] Methods for data analysis of resting energy expenditure measured using indirect calorimetry
    Borges, Juliano H.
    Guerra-Junior, Gil
    Goncalves, Ezequiel M.
    NUTRITION, 2019, 59 : 44 - 49
  • [28] Accuracy of predictive equations versus indirect calorimetry for the evaluation of energy expenditure in cancer patients with solid tumors - An integrative systematic review study
    Mazzo, Rafaela
    Ribeiro, Francieli Barreiro
    Junqueira Vasques, Ana Carolina
    CLINICAL NUTRITION ESPEN, 2020, 35 : 12 - 19
  • [29] Measuring energy expenditure in clinical populations: rewards and challenges
    Psota, T.
    Chen, K. Y.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 (05) : 436 - 442
  • [30] Measuring energy expenditure in clinical populations: rewards and challenges
    T Psota
    K Y Chen