Obtaining interaction diagram of concrete section exposed to fire by mathematical optimization

被引:6
作者
Kim, Han-Soo [1 ]
机构
[1] Konkuk Univ, Dept Architecture, 120 Neungdong Ro, Seoul 05029, South Korea
来源
JOURNAL OF BUILDING ENGINEERING | 2021年 / 44卷
关键词
Interaction diagram; Fire; Composite section; Section analysis; Optimization; SLENDER REINFORCED-CONCRETE; STRESS-STRAIN RELATIONSHIP; COMPOSITE COLUMNS; TRANSIENT CREEP; DESIGN;
D O I
10.1016/j.jobe.2021.102993
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper proposes a novel method for obtaining the axial load-moment (P-M) interaction diagrams of reinforced concrete sections exposed to fire. The problem of obtaining the strength of a reinforced concrete section subjected to an eccentric load was converted into determining an optimum solution of a constrained nonlinear optimization problem. The proposed method does not limit the strains of both concrete and reinforcing bars. A sequential quadratic programming algorithm was used to solve the constrained nonlinear optimization. Discontinuity in the arctangent function was avoided by rotating the atan2 function. A bending moment offset from the tilted axis was introduced to solve the asymmetric section and uneven heating condition. The results of the examples confirm that the proposed method can produce the entire P-M interaction surface of an arbitrarily shaped reinforced composite section exposed to fire. The proposed method is much faster and more versatile than the incremental-iterative procedure. The proposed method can calculate equally spaced points on the Mx-My interaction curve which the incremental-iterative procedure cannot obtain. The proposed method can be applied to any combination of cross-sectional shape, material, and temperature history.
引用
收藏
页数:13
相关论文
共 33 条
  • [1] Abaqus, 2016, ABAQUS ANAL USERS MA
  • [2] Quantifying transient creep effects on fire response of reinforced concrete columns
    Alogla, S.
    Kodur, V. K. R.
    [J]. ENGINEERING STRUCTURES, 2018, 174 : 885 - 895
  • [3] [Anonymous], 2014, ACI 318 14
  • [4] Reinforced concrete columns exposed to standard fire: Comparison among different constitutive models for concrete at high temperature
    Bamonte, P.
    Lo Monte, F.
    [J]. FIRE SAFETY JOURNAL, 2015, 71 : 310 - 323
  • [5] Interaction diagrams for reinforced concrete sections subjected to fire
    Caldas, Rodrigo Barreto
    Sousa, Joao Batista M., Jr.
    Fakury, Ricardo Hallal
    [J]. ENGINEERING STRUCTURES, 2010, 32 (09) : 2832 - 2838
  • [6] CARREIRA DJ, 1985, J AM CONCRETE I, V82, P797
  • [7] Design of biaxially loaded short composite columns of arbitrary section
    Chen, SF
    Teng, JG
    Chan, SL
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2001, 127 (06): : 678 - 685
  • [8] Chen W.F., 1972, 389 LEH U FRITZ ENG, P1
  • [9] Interaction diagrams of reinforced concrete sections in fire: A yield design approach
    Duc Toan Pham
    de Buhan, Patrick
    Florence, Celine
    Heck, Jean-Vivien
    Hong Hai Nguyen
    [J]. ENGINEERING STRUCTURES, 2015, 90 : 38 - 47
  • [10] E.N. CEN, 2002, 199212 EN CEN