Optical analysis of gel dosimeters: Comparison of Fricke and normoxic polymer gels

被引:4
作者
Gambarini, G.
Carrara, M.
Mariani, A.
Pirola, L.
Tomatis, S.
Valente, M.
Vanossi, E.
机构
[1] Univ Milan, Dept Phys, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[3] Politecn Milan, Dept Nucl Engn, Milan, Italy
[4] Natl Canc Inst, Dept Phys, Milan, Italy
关键词
dose imaging; Fricke gel; polymer gel; gel dosimetry; optical imaging; phantoms;
D O I
10.1016/j.nimb.2007.04.085
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The dosimetry method based on optical analysis of gel layers has been experienced utilising both Fricke and polymer (normoxic) gels. The aim of the work was that of investigating the potentiality of a normoxic polymer gel and of performing a further verification of the reliability of Fricke gel dosimeters. Optical absorbance was measured, both with a spectrophotometer and by imaging light transmittance detected with a CCD camera. The results of the study of sensitivity, linearity of the response and reproducibility of the polymer gel dosimeter have shown acceptable performances, except for doses below 2 Gy. The linearity range extends up to 20 Gy. On the other side, dose images and profiles have shown noticeable differences when compared to those calculated or measured with ionisation chambers or Fricke gel dosimeters. Such Fricke dosimeters have given further confirmation of their reliability. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 195
页数:5
相关论文
共 50 条
  • [11] Gamma/neutron dose evaluation using Fricke gel and alanine gel dosimeters to be applied in boron neutron capture therapy
    Mangueira, T. F.
    Silva, C. F.
    Coelho, P. R. P.
    Campos, L. L.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 791 - 794
  • [12] A method for obtaining three-dimensional measurements of HDR brachytherapy dose distributions using Fricke gel dosimeters and optical computed tomography
    Asena, Andre
    Nilsson, Sanna
    Smith, Shaun T.
    Kairn, Tanya
    Crowe, Scott B.
    Trapp, Jamie V.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (01) : 221 - 226
  • [13] Application of normoxic polymer gels in 3D-dosimetry for radiosurgery
    Scheib, Stefan
    Crescenti, Remo
    Vogelsanger, Walter
    Schenkel, Yvonne
    Gianolini, Stefano
    Lazaridis, Emmanuil
    Mack, Andreas
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (03): : 180 - 187
  • [14] Sensitivity calibration procedures in optical-CT scanning of BANG®3 polymer gel dosimeters
    Xu, Y.
    Wuu, Cheng-Shie
    Maryanski, Marek J.
    MEDICAL PHYSICS, 2010, 37 (02) : 861 - 868
  • [15] Simulation of Water Equivalency of Polymer Gel Dosimeters with GAMOS
    Ozbay, Turkan
    Yurt, Aysegul
    Ozsoykal, Ismail
    JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES, 2020, 4 (01): : 51 - 58
  • [16] A normoxic acrylic acid polymer gel for dosimetery in radiation therapy
    Khalid A. Rabaeh
    Issra’ M. E. Hammoudeh
    Belal Moftah
    Ammar A. Oglat
    Molham M. Eyadeh
    Feras M. Aldweri
    Ala’ J. Abdel-Qader
    Slobodan Devic
    Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 665 - 672
  • [17] A normoxic acrylic acid polymer gel for dosimetery in radiation therapy
    Rabaeh, Khalid A.
    Hammoudeh, Issra' M. E.
    Moftah, Belal
    Oglat, Ammar A.
    Eyadeh, Molham M.
    Aldweri, Feras M.
    Abdel-Qader, Ala' J.
    Devic, Slobodan
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (02) : 665 - 672
  • [18] Fricke and polymer gel 2D dosimetry validation using Monte Carlo simulation
    Vedelago, J.
    Chacon Obando, D.
    Malano, F.
    Conejeros, R.
    Figueroa, R.
    Garcia, D.
    Gonzalez, G.
    Romero, M.
    Santibanez, M.
    Strumia, M. C.
    Velasquez, J.
    Mattea, F.
    Valente, M.
    RADIATION MEASUREMENTS, 2016, 91 : 54 - 64
  • [19] Dose-response dependencies of Turnbull blue, modified Fricke, VIPET, and Presage® gel dosimeters in high-dose-rate radiation fields
    Prusova, H.
    Dudas, D.
    Spevacek, V.
    Prusa, P.
    RADIATION MEASUREMENTS, 2023, 161
  • [20] Fabrication of a Normoxic Polymer Gel Dosimeter and its Dose Distribution Characteristics
    Cho, Yu Ra
    Park, Hyung Wook
    Kim, Ae Ran
    Park, Chae Hee
    Bong, Ji Hye
    Lee, Jae Choon
    Kwon, Soo-Il
    Cho, Kwang Hwan
    Lee, Sang Hoon
    Cho, Sam Ju
    Ko, In Ok
    Park, Ji Ae
    Kim, Kyong Min
    Kim, Kum Bae
    Shin, Sang Hun
    Jung, Hai Jo
    Ji, Young Hoon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (01) : 169 - 175