Using multichannel wide-dynamic range compression in severely hearing-impaired listeners: Effects on speech recognition and quality

被引:22
作者
Souza, PE [1 ]
Jenstad, LM [1 ]
Folino, R [1 ]
机构
[1] Univ Washington, Dept Speech & Hearing Sci, Seattle, WA 98105 USA
关键词
D O I
10.1097/00003446-200504000-00002
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: The objective of this study was to compare speech recognition across a sampling of amplification choices available for listeners with severe loss. This includes conventional options (linear with peak clipping and linear with compression limiting) and newer strategies (multichannel wide-dynamic range compression [WDRC]) theorized to better accommodate reduced dynamic range. A second objective was to compare speech quality across the same conditions using a paired-comparison test. Design: Participants were 13 adults with severe sensorineural hearing loss and a control group of seven adults with normal hearing. Test materials included consonant-vowel syllables (speech recognition) and sentences (speech quality). Four amplification conditions were included: peak clipping; compression limiting; two-channel WDRC; and three-channel WDRC, with overall audibility similar across conditions. In the WDRC conditions, the compression ratio was fixed at 3:1 in each channel. Consonant recognition was measured using a closed-set task, and speech quality was measured using a paired-comparison test. Results: For the listeners with severe loss, recognition and preference were lower for a three-channel WDRC system than for a compression limiting system. Specific errors were consistent with poorer transmission of amplitude envelope information by the multichannel WDRC systems. Conclusions: Under some conditions, the benefit of fast-acting, multichannel WDRC systems relative to more linear amplification strategies may be reduced in listeners with severe loss. Performance decrements with these systems are consistent with consequences of broader auditory filters.
引用
收藏
页码:120 / 131
页数:12
相关论文
共 68 条
[1]  
American National Standards Institute, 1996, S361996 ANSI
[2]   Fitting low ratio compression to people with severe and profound hearing losses [J].
Barker, C ;
Dillon, H ;
Newall, P .
EAR AND HEARING, 2001, 22 (02) :130-141
[3]  
Battaglia J., 1990, AUSTR J AUDIOLOGY, V13, P1
[4]   Effect of compression ratio on speech recognition and speech-quality ratings with wide dynamic range compression amplification [J].
Boike, KT ;
Souza, PE .
JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2000, 43 (02) :456-468
[5]   AMPLITUDE COMPRESSION AND PROFOUND HEARING-LOSS [J].
BOOTHROYD, A ;
SPRINGER, N ;
SMITH, L ;
SCHULMAN, J .
JOURNAL OF SPEECH AND HEARING RESEARCH, 1988, 31 (03) :362-376
[6]  
Bustamante D K, 1987, J Rehabil Res Dev, V24, P149
[7]   HEARING-AID GAIN AND FREQUENCY-RESPONSE REQUIREMENTS FOR THE SEVERELY PROFOUNDLY HEARING-IMPAIRED [J].
BYRNE, D ;
PARKINSON, A ;
NEWALL, P .
EAR AND HEARING, 1990, 11 (01) :40-49
[8]  
Byrne D, 1996, J Am Acad Audiol, V7, P377
[9]   Comparison of severely and profoundly hearing-impaired children's amplification preferences with the NAL-RP and the DSL 3.0 prescriptions [J].
Ching, TYC ;
Newall, P ;
Wigney, D .
SCANDINAVIAN AUDIOLOGY, 1997, 26 (04) :219-222
[10]   DEVELOPMENT OF THE CONNECTED SPEECH TEST (CST) [J].
COX, RM ;
ALEXANDER, GC ;
GILMORE, C .
EAR AND HEARING, 1987, 8 (05) :S119-S126