摘要
Arterial flow rate affects intra-aneurysmal hemodynamics but it is not clear how their relationship is. This uncertainty hinders the comparison among studies, including clinical evaluations, like a pre- and post-treatment status, since arterial flow rates may differ at each time acquisition. The purposes of this work are as follows: (1) To study how intra-aneurysmal hemodynamics changes within the full physiological range of arterial flow rates. (2) To provide characteristic curves of intra-aneurysmal velocity, wall shear stress (WSS) and pressure as functions of the arterial flow rate. Fifteen image-based aneurysm models were studied using computational fluid dynamics (CFD) simulations. The full range of physiological arterial flow rates reported in the literature was covered by 11 pulsatile simulations. For each aneurysm, the spatiotemporal-averaged blood flow velocity, WSS and pressure were calculated. Spatiotemporal-averaged velocity inside the aneurysm linearly increases as a function of the mean arterial flow (minimum R-2 > 0.963). Spatiotemporal-averaged WSS and pressure at the aneurysm wall can be represented by quadratic functions of the arterial flow rate (minimum R-2 > 0.996). Quantitative characterizations of spatiotemporal-averaged velocity, WSS and pressure inside cerebral aneurysms can be obtained with respect to the arterial flow rate. These characteristic curves provide more information of the relationship between arterial flow and aneurysm hemodynamics since the full range of arterial flow rates is considered. Having these curves, it is possible to compare experimental studies and clinical evaluations when different flow conditions are used. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:585 / 591
页数:7
相关论文
共 50 条
  • [41] A Novel Hyper-Elastic Thin Film Nitinol Covered Stent Significantly Decreases Intra-Aneurysmal Flow In Vitro
    Chun, Youngjae
    Hur, Soojung C.
    Kealey, Colin P.
    Levi, Daniel S.
    Mohanchandra, K. P.
    Di Carlo, Dino
    Carman, Gregory P.
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2011, 2011, 7984
  • [42] Intra-aneurysmal Onyx embolization for distal aneurysms of the cerebellar arteries
    Gao, Xu
    Liang, Guobiao
    Li, Zhiqing
    Wang, Xiaogang
    Wei, Xuezhong
    Zhang, Haifeng
    Feng, Sizhe
    Lin, Jun
    NEUROLOGICAL RESEARCH, 2012, 34 (02) : 211 - 216
  • [43] Intra-aneurysmal flow patterns and wall shear stresses calculated with computational flow dynamics in an anterior communicating artery aneurysm depend on knowledge of patient-specific inflow rates
    Karmonik, Christof
    Yen, Christopher
    Grossman, Robert G.
    Klucznik, Richard
    Benndorf, Goetz
    ACTA NEUROCHIRURGICA, 2009, 151 (05) : 479 - 485
  • [44] Early Ceasing of Intra-aneurysmal Contrast Opacification During Coil Embolization in Ruptured Aneurysms Compared With Unruptured Aneurysms
    Tsutsumi, Masanori
    Aikawa, Hiroshi
    Nii, Kouhei
    Hamaguchi, Shuko
    Etou, Housei
    Sakamoto, Kimiya
    Yoshida, Hidenori
    Matsumoto, Yoshihisa
    Kazekawa, Kiyoshi
    NEUROSURGERY, 2011, 69 (03) : 651 - 658
  • [45] Coils Coated With the Cyclic Peptide SEK-1005 Accelerate Intra-Aneurysmal Organization
    Sano, Hiroki
    Toda, Mitsuaki
    Sugihara, Takahiro
    Uchiyama, Naoyuki
    Hamada, Jun-ichiro
    Iwata, Hiroo
    NEUROSURGERY, 2010, 67 (04) : 984 - 991
  • [46] Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage
    Froelich, Andreas Maximilian
    Nawka, Marie Teresa
    Ernst, Marielle
    Frischmuth, Isabell
    Fiehler, Jens
    Buhk, Jan-Hendrik
    PLOS ONE, 2018, 13 (02):
  • [47] Comparison of intra-aneurysmal flow modification using optical flow imaging to evaluate the performance of Evolve and Pipeline flow diverting stents
    Cancelliere, Nicole Mariantonia
    Nicholson, Patrick
    Radovanovic, Ivan
    Mendes, Karla Mirella
    Orru, Emanuele
    Krings, Timo
    Pereira, Vitor M.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (08) : 814 - 817
  • [48] Intra-aneurysmal pressure changes during stent-assisted coiling
    Piasecki, Piotr
    Ziecina, Piotr
    Brzozowski, Krzysztof
    Wierzbicki, Marek
    Narloch, Jerzy
    PLOS ONE, 2020, 15 (06):
  • [49] Intra-Aneurysmal High-Resolution 4D MR Flow Imaging for Hemodynamic Imaging Markers in Intracranial Aneurysm Instability
    van Tuijl, R. J.
    den Hertog, C. S.
    Timmins, K. M.
    Velthuis, B. K.
    van Ooij, P.
    Zwanenburg, J. J. M.
    Ruigrok, Y. M.
    van der Schaaf, I. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (11) : 1678 - 1684
  • [50] Intra-aneurysmal microcatheter looping technique for stent-assisted embolization of complex intracranial aneurysms
    Wang, C-C
    Lv, N.
    Feng, Z-Z
    Li, Z-F
    Zhao, R.
    Li, Q.
    Liu, J-M
    Huang, Q-H
    INTERVENTIONAL NEURORADIOLOGY, 2015, 21 (05) : 580 - 584