Accuracy of immunoassay and mass spectrometry urinary free cortisol in the diagnosis of Cushing's syndrome

被引:24
作者
Aranda, G. [1 ,2 ]
Careaga, M. [2 ]
Hanzu, F. A. [1 ,2 ,3 ,4 ]
Patrascioiu, I. [2 ]
Rios, P. [2 ]
Mora, M. [1 ,2 ,3 ,4 ]
Morales-Romero, B. [5 ]
Jimenez, W. [5 ,6 ]
Halperin, I. [1 ,2 ,3 ,4 ]
Casals, G. [5 ]
机构
[1] IDIBAPS, Grp Endocrine Disorders, Barcelona, Spain
[2] Hosp Clin Barcelona, Dept Endocrinol & Nutr, Barcelona, Spain
[3] CIBERDEM, Ctr Invest Red, Barcelona, Spain
[4] Univ Barcelona, Barcelona, Spain
[5] Hosp Clin Univ, Biochem & Mol Genet Serv, IDIBAPS, CIBERehd, Villarroel 170, Barcelona 08036, Spain
[6] Univ Barcelona, Biomed Dept, Barcelona, Spain
关键词
Cushing's syndrome; Urinary free cortisol; Mass spectrometry; Immunoassay; TESTS; TERM;
D O I
10.1007/s11102-016-0730-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Urinary free cortisol (UFC) determination by highly specific methods as mass spectrometry instead of commercially available antibody-based immunoassays is increasingly recommended. However, clinical comparisons of both analytical approaches in the screening of Cushing's syndrome (CS) are not available. The aim of this study was to evaluate the diagnostic value of mass spectrometry versus immunoassay measurements of 24 h-UFC in the screening of CS. Cross-sectional study of 33 histologically confirmed CS patients: 25 Cushing's disease, 5 adrenal CS and 3 ectopic CS; 92 non-CS patients; and 35 healthy controls. UFC by immunoassay (UFCxIA) and mass spectrometry (UFCxMS), urinary free cortisone (UFCo) and UFC:UFCo ratio were measured, together with creatinine-corrected values. Sensitivity, specificity, AUC and Landis and Koch concordance index were determined. AUC for UFCxIA and UFCxMS were 0.77 (CI 0.68-0.87) and 0.77 (CI 0.67-0.87) respectively, with a kappa coefficient 0.60 and strong Landis and Koch concordance index. The best calculated cutoff values were 359 nmol/24 h for UFCxIA (78 % sensitivity, 62 % specificity) and 258.1 nmol/24 h for UCFxMS (53 % sensitivity, 86 % specificity). The upper limit of UFCxIA and UCFxMS reference ranges were 344.7 and 169.5 nmol/24 h respectively. Sensitivity and specificity for CS diagnosis at these cutpoints were 84 and 56 % for UFCxIA and 81 and 54 % for UFCxMS. According to our data, both methods present a very similar diagnostic value. However, results suggest that lower cutoff points for mass spectrometry may be necessary in order to improve clinical sensitivity.
引用
收藏
页码:496 / 502
页数:7
相关论文
共 50 条
[31]   Salivary cortisol measurement -: a reliable method for the diagnosis of Cushing's syndrome [J].
Trilck, M ;
Flitsch, J ;
Lüdecke, DK ;
Jung, R ;
Petersenn, S .
EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2005, 113 (04) :225-230
[32]   Concordance of the late night salivary cortisol in patients with Cushing's syndrome and elevated urine-free cortisol [J].
Doi, Suhail A. R. ;
Clark, Justin ;
Russell, Anthony W. .
ENDOCRINE, 2013, 43 (02) :327-333
[33]   Salivary cortisol and cortisone by LC-MS/MS: validation, reference intervals and diagnostic accuracy in Cushing's syndrome [J].
Antonelli, Giorgia ;
Ceccato, Filippo ;
Artusi, Carlo ;
Marinova, Mariela ;
Plebani, Mario .
CLINICA CHIMICA ACTA, 2015, 451 :247-251
[34]   Salivary cortisol and cortisone in diagnosis of Cushing's syndrome - a comparison of six different analytical methods [J].
Backlund, Nils ;
Brattsand, Goran ;
Lundstedt, Staffan ;
Aardal, Elisabeth ;
Bartuseviciene, Inga ;
Berinder, Katarina ;
Hoybye, Charlotte ;
Burman, Pia ;
Eden Engstrom, Britt ;
Isaksson, Anders ;
Blomgren, Anders ;
Ragnarsson, Oskar ;
Ruetschi, Ulrika ;
Wahlberg, Jeanette ;
Olsson, Tommy ;
Dahlqvist, Per .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (10) :1780-1791
[35]   Update on late-night salivary cortisol for the diagnosis of Cushing's syndrome: methodological considerations [J].
Raff, Hershel .
ENDOCRINE, 2013, 44 (02) :346-349
[36]   Screening and diagnosis of Cushing's syndrome [J].
De Castro, Margaret ;
Moreira, Ayrton C. .
ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2007, 51 (08) :1191-1198
[37]   Cushing’s Syndrome: Screening and Diagnosis [J].
Ceccato F. ;
Boscaro M. .
High Blood Pressure & Cardiovascular Prevention, 2016, 23 (3) :209-215
[38]   Specificity assessment of immunoassay kits for determination of urinary free cortisol concentrations [J].
Horie, Hitoshi ;
Kidowaki, Takeshi ;
Koyama, Yuhei ;
Endo, Tatsuji ;
Homma, Keiko ;
Kambegawa, Akira ;
Aoki, Norihiko .
CLINICA CHIMICA ACTA, 2007, 378 (1-2) :66-70
[39]   Pitfalls in the diagnosis of Cushing's syndrome [J].
Vilar, Lucio ;
Freitas, Maria Da Conceigao ;
Faria, Manuel ;
Montenegro, Renan ;
Casulari, Lutz Augusto ;
Naves, Luciana ;
Bruno, Oscar D. .
ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2007, 51 (08) :1207-1216
[40]   Determination of urinary free cortisol by liquid chromatography-tandem mass spectrometry [J].
Turpeinen, U ;
Stenman, UH .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2003, 63 (02) :143-150