Effect of corneal thinning on Dynamic Contour Tonometry, Goldmann applanation, and Pneumotonometry in a cadaver eye model

被引:0
作者
Nee, MT [1 ]
Kniestedt, C [1 ]
Stamper, RL [1 ]
机构
[1] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
2625
引用
收藏
页码:U18 / U18
页数:1
相关论文
共 50 条
  • [21] Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study
    Mona Pache
    Sonja Wilmsmeyer
    Sonja Lautebach
    Jens Funk
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 763 - 767
  • [22] Comparison of dynamic contour tonometry with Goldmann applanation tonometry in glaucoma practice
    Halkiadakis, Ioannis
    Patsea, Eleni
    Chatzimichali, Katerina
    Skouriotis, Sotiris
    Chalkidou, Sonia
    Amariotakis, Georgios
    Papakonstadinou, Dimitrios
    Theodossiadis, George
    Amariotakis, Apostolos
    Georgopoulos, Gerasimos
    ACTA OPHTHALMOLOGICA, 2009, 87 (03) : 323 - 328
  • [23] Effect of corneal thickness on dynamic contour, rebound, and Goldmann tonometry
    Martinez-de-la-Casa, Jose M.
    Garcia-Feijoo, Julian
    Vico, Eva
    Fernandez-Vidal, Ana
    del Castillo, Jose M. Benitez
    Wasfi, Mohamed
    Garcia-Sanchez, J.
    OPHTHALMOLOGY, 2006, 113 (12) : 2156 - 2162
  • [24] Comparison of dynamic contour tonometry and Goldmann applanation tonometry in relation to central corneal thickness in primary congenital glaucoma
    Marcelo Lopes Silva Jordão
    Vital Paulino Costa
    Maria de Lourdes Veronese Rodrigues
    Jayter Silva Paula
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 117 - 121
  • [25] Comparison of Goldmann Applanation Tonometry and Dynamic Contour Tonometry in the Measurement of Intraocular Pressure in Eyes with Different Corneal Thicknesses
    Roszkowska, A. M.
    De Grazia, L.
    Cirone, M.
    Ferreri, G.
    OPHTHALMOLOGICA, 2009, 223 (04) : 244 - 249
  • [26] Intraoular pressure measurement - Comparison of dynamic contour tonometry and Goldmann applanation tonometry
    Schneider, ED
    Grehn, F
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [27] Goldmann Applanation Tonometry and Dynamic Contour Tonometry are not Correlated With Central Corneal Thickness in Primary Open Angle Glaucoma
    Regev, Guy
    Harris, Alon
    Siesky, Brent
    Shoshani, Yochai
    Egan, Patrick
    Moss, Adam
    Zalish, Miriam
    WuDunn, Darrell
    Ehrlich, Rita
    JOURNAL OF GLAUCOMA, 2011, 20 (05) : 282 - 286
  • [28] Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations
    De Bernardo, Maddalena
    Casaburi, Claudia
    De Pascale, Ilaria
    Capasso, Luigi
    Cione, Ferdinando
    Rosa, Nicola
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [29] Comparison of dynamic contour tonometry and Goldmann applanation tonometry following penetrating keratoplasty
    Kandarakis, Artemios
    Soumplis, Vasileios
    Pitsas, Christos
    Kandarakis, Stylianos
    Halikias, Jiannis
    Karagiannis, Dimitrios
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2010, 45 (05): : 489 - 493
  • [30] Comparison of dynamic contour tonometry and Goldmann applanation tonometry in relation to central corneal thickness in primary congenital glaucoma
    Silva Jordao, Marcelo Lopes
    Costa, Vital Paulino
    Veronese Rodrigues, Maria de Lourdes
    Paula, Jayter Silva
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (01) : 117 - 121