The electrochemical reactions of a copper electrode in Na(2)S solutions were studied using cyclic voltammetry, potentiostatic and galvanostatic measurements. In addition surface examination and morphological studies were applied using scanning electron microscopy (SEM), energy dispersive analysis of X-rays (EDAX). There are three anodic peaks were found in the anodic branch of the voltammogram's. These peaks may be corresponding successively to the formation of Cu(2)S. CuS and Cu(2)O. On the other hand, the cathodic branch contains four peaks. These peaks correspond to the reduction of copper oxide and copper sulfide formed on the anodic branch. (C) 2010 King Saud University. All rights reserved.
引用
收藏
页码:183 / 189
页数:7
相关论文
共 50 条
  • [31] Copper/cuprous sulfide electrode: preparation and performance
    Lina Xiao
    Ding Yuan
    Pei Li
    Li Huang
    Bing-Wei Mao
    Dongping Zhan
    Science China Chemistry, 2015, 58 : 1039 - 1043
  • [32] DETERMINATION OF SULFIDE IN BLOOD WITH AN ION-SELECTIVE ELECTRODE BY PRE-CONCENTRATION OF TRAPPED SULFIDE IN SODIUM-HYDROXIDE SOLUTION
    LINDELL, H
    JAPPINEN, P
    SAVOLAINEN, H
    ANALYST, 1988, 113 (05) : 839 - 840
  • [33] STUDIES ON THE CATHODIC EFFECT OF IRON SULFIDE AND MANGANESE SULFIDE ON THE CORROSION OF IRON IN A 3-PERCENT SODIUM-CHLORIDE SOLUTION
    KELLER, H
    GRABKE, HJ
    WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1981, 32 (12): : 540 - 545
  • [34] Corrosion inhibition of copper by sodium phytate in NaOH solution: Cyclic voltabsorptometry for in situ monitoring of soluble corrosion products
    Wang, Yong-Hong
    He, Jian-Bo
    ELECTROCHIMICA ACTA, 2012, 66 : 45 - 51
  • [35] The effect of inhibitor structure on the corrosion of copper in 0.6 M aqueous sodium chloride solution
    Nandi, M. M.
    Biswas, S.
    Jain, Noopur
    Nandi, S.
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2017, 94 (04) : 369 - 380
  • [36] CORROSION BEHAVIOR OF COPPER IN 3-PERCENT SODIUM-CHLORIDE SOLUTION AND SEAWATER
    CHERNOV, BB
    KUZOVLEVA, KT
    OVSYANNIKOVA, AA
    PROTECTION OF METALS, 1985, 21 (01): : 42 - 46
  • [37] Copper sulfide nanostructures and their sodium storage properties
    Gu, Yarong
    Li, Tingting
    Guo, Bingkun
    Jiang, Yutao
    Wen, Weijia
    Wu, Jinbo
    Zhao, Lijuan
    CRYSTENGCOMM, 2020, 22 (42) : 7082 - 7089
  • [38] Corrosion of copper by sodium halide solutions
    Asselin, FJ
    Rohrman, FA
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1940, 32 : 1015 - 1016
  • [39] LEVELS OF COPPER SULFATE AND SODIUM SULFIDE FOR SWINE
    CROMWELL, GL
    CLARK, TL
    HAYS, VW
    OVERFIEL.JR
    JOURNAL OF ANIMAL SCIENCE, 1973, 36 (01) : 205 - &
  • [40] Action of some Mercaptans in hydrocarbon solution on copper and copper sulfide
    Slagle, KH
    Reid, EE
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1932, 24 : 448 - 451