High total volatile organic compounds pollution in a hospital dental department

被引:14
作者
Liu, Ming-Hui [1 ]
Tung, Tao-Hsin [2 ]
Chung, Fen-Fang [3 ]
Chuang, Li-Chuan [4 ]
Wan, Gwo-Hwa [5 ,6 ,7 ]
机构
[1] Taoyuan Chang Gung Mem Hosp, Dept Pediat Dent, Taoyuan, Taiwan
[2] Cheng Hsin Gen Hosp, Dept Med Res & Educ, Taipei, Taiwan
[3] Chang Gung Univ Sci & Technol, Dept Nursing, Taoyuan, Taiwan
[4] Linkuo Chang Gung Mem Hosp, Dept Pediat Dent, Taoyuan, Taiwan
[5] Chang Gung Univ, Dept Resp Therapy, Coll Med, Taoyuan, Taiwan
[6] Chang Gung Univ Sci & Technol, Dept Resp Therapy, Chiayi, Taiwan
[7] Linkou Chang Gung Mem Hosp, Dept Neurosurg, Taoyuan, Taiwan
关键词
Indoor air quality; Dental department; Particulatematter; Volatile organic compounds; Bacteria; BACTERIAL AEROSOLS; ULTRASONIC SCALERS; INDOOR AIR; CONTAMINATION; DENTISTRY; SPLATTER;
D O I
10.1007/s10661-017-6265-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Bioaerosols produced by dental procedures may affect indoor air quality and cause infections in dental healthcare workers. To provide air quality data that can be used to protect dental healthcare workers, this study evaluated the air quality and its influencing factors in the dental department of the Chang Gung Memorial Hospital in Taiwan. The study was a crosssectional study design. Indoor air quality (IAQ) evaluations were conducted in six locations: pediatric dentistry, craniofacial orthodontic dentistry, periodontal dentistry, and general practice dentistry, instrument washing room, and patient waiting area. The measured air quality parameters included temperature, relative humidity, and concentrations of CO2, total volatile organic compounds (TVOCs), suspended particulate matter (PM), and bacteria. TVOCs concentrations at all six sampling stations were found to exceed the indoor air quality standards prescribed by the Taiwan Environmental Protection Agency. The highest concentrations of atmospheric PM10, PM2.5, and PM1 were found in the periodontal dentistry department, while the lowest concentrations occurred in the patient waiting area. The detection rate for Gram-positive bacteria was highest in the pediatric department (25%) and lowest in the instrument washing room (9%). Micrococcus luteus and Bacillus cereus were the primary pathogens detected. The dental departments of the hospital had a serious TVOCs pollution. The air quality of dental departments deserves long-term surveillance and attention.
引用
收藏
页数:8
相关论文
共 24 条
[1]  
Al-Amad S. H., 2016, J INFECT PUBLIC HEAL, P30032
[2]   Blood contamination of the aerosols produced by in vivo use of ultrasonic scalers [J].
Barnes, JB ;
Harrel, SK ;
Rivera-Hidalgo, F .
JOURNAL OF PERIODONTOLOGY, 1998, 69 (04) :434-438
[3]   Microbial aerosols in general dental practice [J].
Bennett, AM ;
Fulford, MR ;
Walker, JT ;
Bradshaw, DJ ;
Martin, MV ;
Marsh, PD .
BRITISH DENTAL JOURNAL, 2000, 189 (12) :664-667
[4]   EVALUATING SPATTER AND AEROSOL CONTAMINATION DURING DENTAL PROCEDURES [J].
BENTLEY, CD ;
BURKHART, NW ;
CRAWFORD, JJ .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1994, 125 (05) :579-584
[5]   MEASURING HARMFUL LEVELS OF BACTERIA IN DENTAL AEROSOLS [J].
EARNEST, R ;
LOESCHE, W .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1991, 122 (13) :55-57
[6]  
El-Din A. M. T., 1997, Eastern Mediterranean Health Journal, V3, P530
[7]   EFFICACY OF PREPROCEDURAL RINSING WITH AN ANTISEPTIC IN REDUCING VIABLE BACTERIA IN DENTAL AEROSOLS [J].
FINE, DH ;
MENDIETA, C ;
BARNETT, ML ;
FURGANG, D ;
MEYERS, R ;
OLSHAN, A ;
VINCENT, J .
JOURNAL OF PERIODONTOLOGY, 1992, 63 (10) :821-824
[8]   REDUCING BACTERIA IN DENTAL AEROSOLS - PREPROCEDURAL USE OF AN ANTISEPTIC MOUTHRINSE [J].
FINE, DH ;
YIP, J ;
FURGANG, D ;
BARNETT, ML ;
OLSHAN, AM ;
VINCENT, J .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1993, 124 (05) :56-58
[10]   Reduction of aerosols produced by ultrasonic scalers [J].
Harrel, SK ;
Barnes, JB ;
RiveraHidalgo, F .
JOURNAL OF PERIODONTOLOGY, 1996, 67 (01) :28-32