Performance improvement of multi-stage flash desalination with thermal vapor compression, a practical consideration
被引:12
作者:
Assiri, Musa
论文数: 0引用数: 0
h-index: 0
机构:
Saline Water Convers Corp, Jubail Ind City, Saudi ArabiaSaline Water Convers Corp, Jubail Ind City, Saudi Arabia
Assiri, Musa
[1
]
Antar, Mohamed A.
论文数: 0引用数: 0
h-index: 0
机构:
KFUPM, Dept Mech Engn, Dhahran, Saudi Arabia
KFUPM, Interdisciplinary Res Ctr Membranes & Water Secur, Dhahran, Saudi ArabiaSaline Water Convers Corp, Jubail Ind City, Saudi Arabia
Antar, Mohamed A.
[2
,3
]
Hamed, Osman
论文数: 0引用数: 0
h-index: 0
机构:
Saline Water Convers Corp, Jubail Ind City, Saudi ArabiaSaline Water Convers Corp, Jubail Ind City, Saudi Arabia
Hamed, Osman
[1
]
Lawal, Dahiru U.
论文数: 0引用数: 0
h-index: 0
机构:
KFUPM, Interdisciplinary Res Ctr Membranes & Water Secur, Dhahran, Saudi ArabiaSaline Water Convers Corp, Jubail Ind City, Saudi Arabia
Lawal, Dahiru U.
[3
]
机构:
[1] Saline Water Convers Corp, Jubail Ind City, Saudi Arabia
[2] KFUPM, Dept Mech Engn, Dhahran, Saudi Arabia
[3] KFUPM, Interdisciplinary Res Ctr Membranes & Water Secur, Dhahran, Saudi Arabia
This work focuses on reducing the energy needed to desalinate seawater through novel integration of MSF system with a thermal vapor compressor (TVC). The analysis extends to investigate positioning the TVC in different locations to find the most suitable location for TVC connection. Two different configurations of TVC's integration to MSF (single or double TVC's with MSF system) are proposed. Analytical models for brine recirculation MSF and MSF-TVC have been established and validated against real plant data where a very good agreement was attained for important process parameters. Results show a significant improvement in thermal performance ratio (from 8.58 to 12.96) for the MSF-TVC, while the steam consumption has also been reduced by 33%. Entrained vapor by TVC from a selected stage adversely affects the heat recovery of the recirculating brine, which drops the top brine temperature (TBT) by about 3 degrees C. This resulted in a decrease in the productivity that is rectified by increasing the rate of brine recirculation to maintain the same desalinated water productivity. Energy analysis revealed a significant drop of about 34% in cooling seawater, which partly leads to energy saving of about 16%. Therefore, the proposed MSF-TVC system shows higher thermal performance ratio, a decrease in the required heat transfer area, and reduction in the required energy per unit mass of pure water produced. Moreover, since the TVC requires higher motive steam pressure, this implies smaller steam pipe diameter. The effect on the integrated power plant load changes is also considered.
机构:
Masdar Inst Sci & Technol, Abu Dhabi, U Arab EmiratesMasdar Inst Sci & Technol, Abu Dhabi, U Arab Emirates
Al-Hamahmy, Mohamed
;
Fath, Hassan E. S.
论文数: 0引用数: 0
h-index: 0
机构:
Masdar Inst Sci & Technol, Abu Dhabi, U Arab EmiratesMasdar Inst Sci & Technol, Abu Dhabi, U Arab Emirates
Fath, Hassan E. S.
;
Khanafer, Khalil
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Australian Coll Kuwait, Dept Mech Engn, Kuwait, KuwaitMasdar Inst Sci & Technol, Abu Dhabi, U Arab Emirates
机构:
Masdar Inst Sci & Technol, Abu Dhabi, U Arab EmiratesMasdar Inst Sci & Technol, Abu Dhabi, U Arab Emirates
Al-Hamahmy, Mohamed
;
Fath, Hassan E. S.
论文数: 0引用数: 0
h-index: 0
机构:
Masdar Inst Sci & Technol, Abu Dhabi, U Arab EmiratesMasdar Inst Sci & Technol, Abu Dhabi, U Arab Emirates
Fath, Hassan E. S.
;
Khanafer, Khalil
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Australian Coll Kuwait, Dept Mech Engn, Kuwait, KuwaitMasdar Inst Sci & Technol, Abu Dhabi, U Arab Emirates