Stabilization and modulation of the output power of submillimeter wave gyrotron

被引:10
|
作者
Ogawa, I
Idehara, T
Ui, M
Mitsudo, S
Förster, W
机构
[1] Fukui Univ, Fac Engn, Fukui 9108507, Japan
[2] Fukui Univ, Res Ctr Dev Far Infrared Reg, Fukui 9108507, Japan
[3] Univ Stuttgart, Inst Plasmaforsch, D-70569 Stuttgart, Germany
关键词
gyrotron; stabilization; modulation;
D O I
10.1016/S0920-3796(00)00535-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
High frequency, medium power gyrotrons (Gyrotron FU series) have been developed at the Fukui University as radiation sources convering a broad frequency band from millimeter to submillimeter wave region. We have performed cw operation of the Gyrotron FU IV. However, the output power was not stable (approximately several tens %) due to the fluctuation of the cathode potential (similar to 40 V). The output power was stabilized within several percent by controlling the anode potential. Such a technique was also used for amplitude modulation of the gyrotron output. Improved stabilization of output power and effective modulation will be achieved by stabilizing the cathode potential. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:571 / 576
页数:6
相关论文
共 50 条
  • [21] SUBMILLIMETER-WAVE HARMONIC GYROTRON EXPERIMENT
    SPIRAHAKKARAINEN, S
    KREISCHER, KE
    TEMKIN, RJ
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1990, 18 (03) : 334 - 342
  • [22] High quality operation of a submillimeter wave gyrotron
    Ogawa, I
    Idehara, T
    Hoshizuki, H
    Myodo, M
    Nagao, K
    Mitsudo, S
    Hori, T
    IRMMW-THZ2005: THE JOINT 30TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES AND 13TH INTERNATIONAL CONFERENCE ON TERAHERTZ ELECTRONICS, VOLS 1 AND 2, 2005, : 433 - 434
  • [23] MODE COOPERATION IN A SUBMILLIMETER-WAVE GYROTRON
    IDEHARA, T
    SHIMIZU, Y
    PHYSICS OF PLASMAS, 1994, 1 (10) : 3145 - 3147
  • [24] THE OPERATION OF A MEGAWATT GYROTRON IN THE SUBMILLIMETER WAVE REGION
    KREISCHER, KE
    GRIMM, TL
    GUSS, WC
    TEMKIN, RJ
    1989 INTERNATIONAL ELECTRON DEVICES MEETING, TECHNICAL DIGEST, 1989, : 751 - 754
  • [25] MEASUREMENT OF FREQUENCY-SPECTRUM OF SUBMILLIMETER-WAVE GYROTRON OUTPUT USING MICHELSON INTERFEROMETER
    IDEHARA, T
    TATSUKAWA, T
    OGAWA, I
    YAMAGISHI, Y
    KANEMAKI, T
    APPLIED PHYSICS LETTERS, 1993, 62 (08) : 832 - 833
  • [26] Accurate frequency measurement of a submillimeter wave gyrotron output using a far-infrared laser as a reference
    Idehara, T
    Mitsudo, S
    Saito, S
    Ogawa, I
    Okajima, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (05): : 2860 - 2862
  • [27] Dependence of output power on cavity length in a gyrotron backward wave oscillator
    Kamada, K
    Nawashiro, K
    Tamagawa, F
    Lee, CY
    Yoshida, H
    Kawasaki, S
    Ando, R
    Masuzaki, M
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2000, 21 (09): : 1441 - 1449
  • [28] Study of electron beam misalignment in a submillimeter wave gyrotron
    Fukui Univ, Fukui, Japan
    Int J Infrared Millim Waves, 10 (1303-1316):
  • [29] Study of Electron Beam Misalignment in a Submillimeter Wave Gyrotron
    T. Idehara
    K. Shibutani
    H. Nojima
    M. Pereyaslavets
    K. Yoshida
    I. Ogawa
    T. Tatsukawa
    International Journal of Infrared and Millimeter Waves, 1998, 19 : 1303 - 1316
  • [30] DEVELOPMENT OF SUBMILLIMETER-WAVE GYROTRON FOR PLASMA DIAGNOSTICS
    SHIMIZU, Y
    MAKINO, S
    ICHIKAWA, K
    IDEHARA, T
    OGAWA, I
    FUSION ENGINEERING AND DESIGN, 1995, 26 (1-4) : 335 - 340