Punching strength of slabs reinforced for shear with offcuts of rolled steel I-section beams

被引:19
作者
Gomes, R
Regan, P
机构
[1] Univ Fed Goiania, Escola Engn Civil, BR-74605220 Goiania, Go, Brazil
[2] Univ Westminster, Sch Architecture & Civil Engn, London NW1 5LS, England
关键词
D O I
10.1680/macr.1999.51.2.121
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Punching shear failure may occur at columns supporting flat slabs or at concentrated loads. The rupture is brittle and may occur clearly below the flexural capacity of the slab. This work aims to analyse the symmetric punching resistance of reinforced concrete flat slabs with shear reinforcement. Twelve 200 mm thick slabs representing regions around columns, loaded at the centre and reacted at the edges, were tested up to failure. Short offcuts of steel I-beams were used as shear reinforcement. The principal variables considered in the tests were the area, number and distribution of the shear steel elements. All the slabs failed by punching, and the failure load of the specimen with the most reinforcement was more than twice that of the slabs without shear reinforcement.
引用
收藏
页码:121 / 129
页数:9
相关论文
共 12 条
[1]  
[Anonymous], 1991, CEB FIP MODEL CODE 1, V203
[2]  
[Anonymous], 1960, T ROY I TECHNOL
[3]  
*BRIT STAND I, 1993, 8110 BSI
[4]  
DILGER WH, 1981, P ASCE, V107, P2403
[5]  
ELSTNER RC, 1956, J AM CONCRETE I, V28, P29
[6]  
GOMES RB, 1991, THESIS U WESTMINSTER
[7]  
GRAF O, 1933, DTSCH AUSSCHUSS EISE, V73, P1
[8]  
KINNUNEN S, 1963, 41 I BYGGN KUNGL TEK
[9]  
Regan P E., 1985, The Structural Engineer, V63B, P76
[10]  
REGAN PE, 1985, COMITE EURO INT BETO, V168