Penetration of fine particles through rough cracks

被引:29
作者
Lai, Alvin C. K. [1 ]
Fung, Joanna L. S. [1 ]
Li, M. [1 ]
Leung, K. Y. [1 ]
机构
[1] City Univ Hong Kong, Dept Civil & Architectural Engn, Kowloon Tong, Hong Kong, Peoples R China
关键词
Building crack; Penetration; Rough surfaces; Model; Fine aerosols; TURBULENT CHANNEL FLOW; AEROSOL DEPOSITION; AIR-POLLUTION; INDOOR; SMOOTH; OUTDOOR;
D O I
10.1016/j.atmosenv.2012.06.053
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Many building materials have random roughness protrusion scales of up to hundreds of micrometers. A scaled down experimental facility was designed to investigate fine particles' penetration through a straight, smooth and rough crack under four different pressures ranging from 2 to 8 Pa. Sandpapers with three different roughness scales were used to create 10 to 100 micron rough surfaces. Particle concentration for sizes ranging from 20 to 500 nm was measured to determine the penetration. Contrary to expectations, the results are not sensitive to roughness scales. Besides, it is also noticed that under low differential pressure scenario, deposition for rough cracks for small particles is higher than that of smooth crack which will offer better protection for indoor exposure. A simple mathematical model was also developed to predict particle deposition on rough surfaces by diffusion mechanism on extended surfaces. The experimental results match well with the model prediction. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:436 / 443
页数:8
相关论文
共 35 条
[1]   Relative contribution of outdoor and indoor particle sources to indoor concentrations [J].
Abt, E ;
Suh, HH ;
Catalano, P ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (17) :3579-3587
[2]  
Carslaw H. S., 1959, Conduction of Heat in Solids, DOI DOI 10.2307/3610347
[3]   Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor [J].
Chen, Chun ;
Zhao, Bin .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (02) :275-288
[4]   Symptoms in pediatric asthmatics and air pollution: Differences in effects by symptom severity, anti-inflammatory medication use and particulate averaging time [J].
Delfino, RJ ;
Zeiger, RS ;
Seltzer, JM ;
Street, DH .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1998, 106 (11) :751-761
[5]   Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios [J].
Fogh, CL ;
Byrne, MA ;
Roed, J ;
Goddard, AJH .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (15) :2193-2203
[6]  
Fuchs N.A., 1964, MECH AEROSOLS, DOI DOI 10.1002/QJ.49709138822
[7]   A unified eulerian theory of turbulent deposition to smooth and rough surfaces [J].
Guha, A .
JOURNAL OF AEROSOL SCIENCE, 1997, 28 (08) :1517-1537
[8]   Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom [J].
Guo, H. ;
Morawska, L. ;
He, C. ;
Gilbert, D. .
ATMOSPHERIC ENVIRONMENT, 2008, 42 (04) :757-768
[9]  
HARRISON AW, 1979, J COLLOID INTERF SCI, V69, P563, DOI 10.1016/0021-9797(79)90144-9
[10]   Particle penetration through rectangular-shaped cracks [J].
Jeng, C. -J. ;
Kindzierski, W. B. ;
Smith, D. W. .
JOURNAL OF ENVIRONMENTAL ENGINEERING AND SCIENCE, 2006, 5 :S111-S119