A System for Simple Robotic Walking Assistance With Linear Impulses at the Center of Mass

被引:9
作者
Gonabadi, Arash Mohammadzadeh [1 ,2 ]
Antonellis, Prokopios [1 ,2 ]
Malcolm, Philippe [1 ,2 ]
机构
[1] Univ Nebraska, Dept Biomech, Omaha, NE 68182 USA
[2] Univ Nebraska, Ctr Res Human Movement Variabil, Omaha, NE 68182 USA
基金
美国国家卫生研究院;
关键词
Force; Legged locomotion; Exoskeletons; Timing; Pulleys; Fuses; Aiding force; cable robotics; center of mass~(COM); rehabilitation; walking; ENERGY-COST; EXOSKELETON ASSISTANCE; LOCOMOTOR ADAPTATION; MECHANICAL WORK; METABOLIC COST; STROKE; GAIT; FORCES; BENEFITS; ENERGETICS;
D O I
10.1109/TNSRE.2020.2988619
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Walking can be simplified as an inverted pendulum motion where both legs generate linear impulses to redirect the center of mass (COM) into every step. In this work, we describe a system to assist walking in a simpler way than exoskeletons by providing linear impulses directly at the COM instead of providing torques at the joints. We developed a novel waist end-effector and high-level controller for an existing cable-robot. The controller allows for the application of cyclic horizontal force profiles with desired magnitudes, timings, and durations based on detection of the step timing. By selecting a lightweight rubber series elastic element with optimal stiffness and carefully tuning the gains of the closed-loop proportional-integral-derivative (PID) controller in a number of single-subject experiments, we were able to reduce the within-step root mean square error between desired and actual forces up to 1.21% of body weight. This level of error is similar or lower compared to the performance of other robotic tethers designed to provide variable or constant forces at the COM. The system can produce force profiles with peaks of up to 15 +/- 2% of body weight within a root mean square error (RMSE) of 2.5% body weight. This system could be used to assist patient populations that require levels of assistance that are greater than current exoskeletons and in a way that does not make the user rely on vertical support.
引用
收藏
页码:1353 / 1362
页数:10
相关论文
共 79 条
[1]   Energy optimization is a major objective in the real-time control of step width in human walking [J].
Abram, Sabrina J. ;
Selinger, Jessica C. ;
Donelan, J. Maxwell .
JOURNAL OF BIOMECHANICS, 2019, 91 :85-91
[2]  
[Anonymous], 2016, J NEUROENGINEERING R
[3]  
Antonellis P., 2019, P INT SOC BIOM AM SO, P1355
[4]   Modular footwear that partially offsets downhill or uphill grades minimizes the metabolic cost of human walking [J].
Antonellis, Prokopios ;
Frederick, Cory M. ;
Gonabadi, Arash Mohammadzadeh ;
Malcolm, Philippe .
ROYAL SOCIETY OPEN SCIENCE, 2020, 7 (02)
[5]   Altering gait variability with an ankle exoskeleton [J].
Antonellis, Prokopios ;
Galle, Samuel ;
De Clercq, Dirk ;
Malcolm, Philippe .
PLOS ONE, 2018, 13 (10)
[6]  
Asbeck Alan T, 2013, IEEE Int Conf Rehabil Robot, V2013, P6650455, DOI 10.1109/ICORR.2013.6650455
[7]   A soft robotic exosuit improves walking in patients after stroke [J].
Awad, Louis N. ;
Bae, Jaehyun ;
O'Donnell, Kathleen ;
De Rossi, Stefano M. M. ;
Hendron, Kathryn ;
Sloot, Lizeth H. ;
Kudzia, Pawel ;
Allen, Stephen ;
Holt, Kenneth G. ;
Ellis, Terry D. ;
Walsh, Conor J. .
SCIENCE TRANSLATIONAL MEDICINE, 2017, 9 (400)
[8]   Reducing The Cost of Transport and Increasing Walking Distance After Stroke: A Randomized Controlled Trial on Fast Locomotor Training Combined With Functional Electrical Stimulation [J].
Awad, Louis N. ;
Reisman, Darcy S. ;
Pohlig, Ryan T. ;
Binder-Macleod, Stuart A. .
NEUROREHABILITATION AND NEURAL REPAIR, 2016, 30 (07) :661-670
[9]  
Bhat SG, 2019, 2019 WEARABLE ROBOTICS ASSOCIATION CONFERENCE (WEARRACON), P68, DOI [10.1109/WEARRACON.2019.8719396, 10.1109/wearracon.2019.8719396]
[10]  
Brown G, 2017, IEEE ENG MED BIO, P66, DOI 10.1109/EMBC.2017.8036764