Real-time implementation of grey fuzzy terminal sliding mode control for PWM DC-AC converters

被引:31
作者
Chang, E. -C. [1 ]
Liang, T. -J. [1 ]
Chen, J. -F [1 ]
Chang, F. -J. [2 ]
机构
[1] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 701, Taiwan
[2] Natl United Univ, Dept Elect Engn, Lienda 36003, Miaoli, Taiwan
关键词
D O I
10.1049/iet-pel:20070295
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Classical terminal sliding mode control (TSMC) has finite system state convergence time and is insensitive to disturbances and uncertainties within expected limits. However, TSMC may chatter when uncertainty values are overestimated or may exhibit a steady-state error when uncertainty values are underestimated. An improved TSMC is proposed by the use of a mathematically simple and computationally fast grey prediction (GP) methodology, which is then fine-tuned by the use of fuzzy control methodology for PWM DC-AC converters. First, GP methodology is employed to deal with classical TSMC chattering and steady-state error problems. Fuzzy control is then used to tune the GP forecasting value for improved rise time and overshoot characteristics. The system is evaluated by simulation and also by real experiment. Both evaluation methods confirm that the proposed controller achieves low total harmonic distortion under non-linear loading conditions and fast dynamic response under transient loading conditions. Because the proposed grey-fuzzy TSMC methodology is simpler to implement than prior methods and offers more efficient computation, it will be of interest to designers of related control systems.
引用
收藏
页码:235 / 244
页数:10
相关论文
共 20 条
[1]  
[Anonymous], P 7 S FOOTW BIOM CLE
[2]   Sliding-mode control design of a boost-buck switching converter for AC signal generation [J].
Biel, D ;
Guinjoan, F ;
Fossas, E ;
Chavarria, J .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2004, 51 (08) :1539-1551
[3]   Distribution system restoration using the hybrid fuzzy-grey method [J].
Chen, WH ;
Tsai, MS ;
Kuo, HL .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (01) :199-205
[4]   Integral variable-structure grey control for magnetic levitation system [J].
Chiang, H. -K. ;
Chen, C. -A. ;
Li, M. -Y. .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2006, 153 (06) :809-814
[5]  
CHIANG HK, 2004, IEE P-ELECT POW APPL, V151, P189
[6]  
Deng Julong, 1989, Journal of Grey Systems, V1, P1
[7]   A on-line rule tuning grey prediction fuzzy control system design [J].
Feng, HM ;
Wong, CC .
PROCEEDING OF THE 2002 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS, VOLS 1-3, 2002, :1316-1321
[8]   Novel vector control system using deadbeat-controlled PWM inverter with output LC filter [J].
Kojima, M ;
Hirabayashi, K ;
Kawabata, Y ;
Ejiogu, EC ;
Kawabata, T .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (01) :162-169
[9]  
Kukrer O, 2006, IECON 2006, P331
[10]  
Martin JP, 2002, IEEE POWER ELECTRON, P909, DOI 10.1109/PSEC.2002.1022570