Polyurethane-doped platinum nanoparticles modified carbon paste electrode for the sensitive and selective voltammetric determination of free copper ions in biological samples

被引:29
作者
Abd El-Raheem, Hany [1 ,2 ]
Hassan, Rabeay Y. A. [1 ,3 ]
Khaled, Rehab [4 ]
Farghali, Ahmed [2 ]
El-Sherbiny, Ibrahim M. [1 ]
机构
[1] Zewail City Sci & Technol, Ctr Mat Sci, Giza 12578, Egypt
[2] Beni Suef Univ, Fac Postgrad Studies Adv Sci, Mat Sci & Nanotechnol Dept, Bani Suwayf, Egypt
[3] Natl Res Ctr, Appl Organ Chem Dept, Giza 12622, Egypt
[4] Beni Suef Univ, Fac Sci, Chem Dept, Bani Suwayf, Egypt
关键词
Voltammetric analysis; Polyurethane-doped nanoparticles; Copper ions determination; Biological samples analysis; SQUARE-WAVE VOLTAMMETRY; ELECTROCHEMICAL DETECTION; WATER SAMPLES; COBALT; PRESSURE; SERUM; FOAM;
D O I
10.1016/j.microc.2020.104765
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Copper ions play an important role in various biochemical and physiological processes. Herein, for the first time, we report and investigate the electrochemical characteristics of polyurethane (PU)-modified electrodes to identify their potential use in sensing of copper ions. Using ferricyanide as the redox probe, PU alone exhibited weak electrochemical signals due to its low electrical conductivity. Therefore, new series of nanocomposites of PU with nano-structured materials such as silver, gold, copper, platinum and magnetic nanoparticles, in addition to the graphene oxide, multi-walled carbon nanotubes and manganese dioxide nanowires were developed, and their electrochemical performances were evaluated as electrode modifiers. The voltammetric signals showed that the electrode modified with PU-doped platinum nanoparticles (PU/Pt NPs) has depicted the highest voltammetric response with well-defined redox peaks. Hence, a full electrochemical assay was optimized and a linear range of copper ions from 100 ng/ml to 1000 ng/ml was achieved, while the calculated values of the limit of detection (LOD) as well limit of quantification (LOQ) were 16.72 ng/ml and 50.66 ng/ml, respectively. Eventually, copper ions were determined and validated in digested serum, urine, and acidified tap water samples, and the atomic force microscopy was used as the reference method for the validation. The developed PUmodified electrodes are cost-effective and depicted high environmental benefits since they allow the accurate detection of copper ions with no prior complicated treatments. Besides, the proposed method found to be highly sensitive and selective, and could be used successfully to determine the trace amounts of copper ions in real biological and environmental samples.
引用
收藏
页数:9
相关论文
共 38 条
  • [1] Polyurethane types, synthesis and applications - a review
    Akindoyo, John O.
    Beg, M. D. H.
    Ghazali, Suriati
    Islam, M. R.
    Jeyaratnam, Nitthiyah
    Yuvaraj, A. R.
    [J]. RSC ADVANCES, 2016, 6 (115) : 114453 - 114482
  • [2] Polyurethane-acrylate based films as humidity sensors
    Bosch, P
    Fernández, A
    Salvador, EF
    Corrales, T
    Catalina, F
    Peinado, C
    [J]. POLYMER, 2005, 46 (26) : 12200 - 12209
  • [3] Dietary copper and human health: Current evidence and unresolved issues
    Bost, Muriel
    Houdart, Sabine
    Oberli, Marion
    Kalonji, Esther
    Huneau, Jean-Francois
    Margaritis, Irene
    [J]. JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2016, 35 : 107 - 115
  • [4] Inherently conducting polymer modified polyurethane smart foam for pressure sensing
    Brady, S
    Diamond, D
    Lau, KT
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2005, 119 (02) : 398 - 404
  • [5] Free copper in serum: An analytical challenge and its possible applications
    Catalani, Simona
    Paganelli, Matteo
    Gilberti, Maria Enrica
    Rozzini, Luca
    Lanfranchi, Francesco
    Padovani, Alessandro
    Apostoli, Pietro
    [J]. JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2018, 45 : 176 - 180
  • [6] Effects of temperature and vapor pressure on the gas sensing behavior of carbon black filled polyurethane composites
    Chen, SG
    Hu, JW
    Zhang, MQ
    Rong, MZ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 105 (02): : 187 - 193
  • [7] Determination of copper(II) ion in food using an ionic liquids-carbon nanotubes-based ion-selective electrode
    Fan, Yunchang
    Xu, Chen
    Wang, Rupeng
    Hu, Guitao
    Miao, Juan
    Hai, Kun
    Lin, Chong
    [J]. JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2017, 62 : 63 - 68
  • [8] Colorimetric determination of copper(II) ions by filtration on sol-gel membrane doped with diphenylcarbazide
    Feng, Liang
    Zhang, Yue
    Wen, Liying
    Shen, Zheng
    Guan, Yafeng
    [J]. TALANTA, 2011, 84 (03) : 913 - 917
  • [9] Safety guidelines for copper in water
    Fitzgerald, DJ
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1998, 67 (05) : 1098S - 1102S
  • [10] An electrochemical sensor for the determination of Cu(II) using a modified electrode with ferrocenyl crown ether compound by square wave anodic stripping voltammetry
    Flores, Erick
    Pizarro, Jaime
    Godoy, Fernando
    Segura, Rodrigo
    Gomez, Alejandra
    Agurto, Nicolas
    Sepulveda, Pamela
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 251 : 433 - 439