Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software

被引:206
作者
Lee, Young Han [1 ,2 ]
Park, Kwan Kyu [3 ]
Song, Ho-Taek [1 ,2 ]
Kim, Sungjun [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Dept Radiol, Res Inst Radiol Sci, Med Convergence Res Inst,Coll Med, Seoul 120752, South Korea
[2] Yonsei Univ, Severance Biomed Sci Inst, Coll Med, Seoul 120752, South Korea
[3] Yonsei Univ, Dept Orthopaed Surg, Coll Med, Seoul 120752, South Korea
关键词
Dual-energy CT; Computed tomography; Metallic artefacts; REFORMATTED PROJECTIONS; COMPUTED-TOMOGRAPHY; HIP; REPLACEMENT; HARDWARE; IMPLANTS;
D O I
10.1007/s00330-011-2370-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To assess the usefulness of gemstone spectral imaging (GSI) dual-energy CT (DECT) with/without metal artefact reduction software (MARs). Methods The DECTs were performed using fast kV-switching GSI between 80 and 140 kV. The CT data were retro-reconstructed with/without MARs, by different displayed fields-of-view (DFOV), and with synthesised monochromatic energy in the range 40-140 keV. A phantom study of size and CT numbers was performed in a titanium plate and a stainless steel plate. A clinical study was performed in 26 patients with metallic hardware. All images were retrospectively reviewed in terms of the visualisation of periprosthetic regions and the severity of beam-hardening artefacts by using a five-point scale. Results The GSI-MARs reconstruction can markedly reduce the metal-related artefacts, and the image quality was affected by the prosthesis composition and DFOV. The spectral CT numbers of the prosthesis and periprosthetic regions showed different patterns on stainless steel and titanium plates. Conclusion Dual-energy CT with GSI-MARs can reduce metal-related artefacts and improve the delineation of the prosthesis and periprosthetic region. We should be cautious when using GSI-MARs because the image quality was affected by the prosthesis composition, energy (in keV) and DFOV. The metallic composition and size should be considered in metallic imaging with GSI-MARs reconstruction. Key Points Metal-related artefacts can be troublesome on musculoskeletal computed tomography (CT). Gemstone spectral imaging (GSI) with dual-energy CT (DECT) offers a novel solution GSI and metallic artefact reduction software (GSI-MAR) can markedly reduce these artefacts. However image quality is influenced by the prosthesis composition and other parameters. We should be aware about potential overcorrection when using GSI-MARs.
引用
收藏
页码:1331 / 1340
页数:10
相关论文
共 50 条
  • [31] Iterative metal artefact reduction in CT: can dedicated algorithms improve image quality after spinal instrumentation?
    Aissa, J.
    Thomas, C.
    Sawicki, L. M.
    Caspers, J.
    Kroepil, P.
    Antoch, G.
    Boos, J.
    CLINICAL RADIOLOGY, 2017, 72 (05) : 428.e7 - 428.e12
  • [32] Reduction of dental metallic artefacts in CT: Value of a newly developed algorithm for metal artefact reduction (O-MAR)
    Kidoh, M.
    Nakaura, T.
    Nakamura, S.
    Tokuyasu, S.
    Osakabe, H.
    Harada, K.
    Yamashita, Y.
    CLINICAL RADIOLOGY, 2014, 69 (01) : E11 - E16
  • [33] The pilot study of dual-energy CT gemstone spectral imaging on the image quality of hand tendons
    Deng, Kai
    Li, Wei
    Wang, Jun-jun
    Wang, Guang-li
    Shi, Hao
    Zhang, Cheng-qi
    CLINICAL IMAGING, 2013, 37 (05) : 930 - 933
  • [34] Assessment of metal artefact reduction around dental titanium implants in cone beam CT
    Parsa, A.
    Ibrahim, N.
    Hassan, B.
    Syriopoulos, K.
    van der Stelt, P.
    DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (07)
  • [35] Application of dual-energy CT to suppression of metal artefact caused by pedicle screw fixation in radiotherapy: a feasibility study using original phantom
    Wang, Tianyuan
    Ishihara, Takeaki
    Kono, Atsushi
    Yoshida, Naoki
    Akasaka, Hiroaki
    Mukumoto, Naritoshi
    Yada, Ryuichi
    Ejima, Yasuo
    Yoshida, Kenji
    Miyawaki, Daisuke
    Kakutani, Kenichiro
    Nishida, Kotaro
    Negi, Noriyuki
    Minami, Toshiaki
    Aoyama, Yuuichi
    Takahashi, Satoru
    Sasaki, Ryohei
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (15) : 6226 - 6245
  • [36] Metal artifact reduction by monoenergetic extrapolation of dual-energy CT in patients with metallic implants
    Lee, Ka Yin Gregory
    Cheng, Hei Man Joyce
    Chu, Chi Yeung
    Tam, Chi Wai Annie
    Kan, Wai Kuen
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [37] Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?
    De Crop, An
    Casselman, Jan
    Van Hoof, Tom
    Dierens, Melissa
    Vereecke, Elke
    Bossu, Nicolas
    Pamplona, Jaime
    D'Herde, Katharina
    Thierens, Hubert
    Bacher, Klaus
    NEURORADIOLOGY, 2015, 57 (08) : 841 - 849
  • [38] Effect of a saline flush technique for head and neck imaging in dual-energy CT: improvement of image quality and perivenous artefact reduction using virtual monochromatic imaging
    Washio, H.
    Ohira, S.
    Kanayama, N.
    Wada, K.
    Karino, T.
    Komiyama, R.
    Miyazaki, M.
    Teshima, T.
    CLINICAL RADIOLOGY, 2019, 74 (10) : 805 - 812
  • [39] Frequency split metal artefact reduction in pelvic computed tomography
    M. M. Lell
    E. Meyer
    M. Schmid
    R. Raupach
    M. S. May
    M. Uder
    M. Kachelriess
    European Radiology, 2013, 23 : 2137 - 2145
  • [40] Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses
    Wellenberg, R. H. H.
    Boomsma, M. F.
    van Osch, J. A. C.
    Vlassenbroek, A.
    Milles, J.
    Edens, M. A.
    Streekstra, G. J.
    Slump, C. H.
    Maas, M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 88 : 61 - 70