Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software

被引:206
作者
Lee, Young Han [1 ,2 ]
Park, Kwan Kyu [3 ]
Song, Ho-Taek [1 ,2 ]
Kim, Sungjun [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Dept Radiol, Res Inst Radiol Sci, Med Convergence Res Inst,Coll Med, Seoul 120752, South Korea
[2] Yonsei Univ, Severance Biomed Sci Inst, Coll Med, Seoul 120752, South Korea
[3] Yonsei Univ, Dept Orthopaed Surg, Coll Med, Seoul 120752, South Korea
关键词
Dual-energy CT; Computed tomography; Metallic artefacts; REFORMATTED PROJECTIONS; COMPUTED-TOMOGRAPHY; HIP; REPLACEMENT; HARDWARE; IMPLANTS;
D O I
10.1007/s00330-011-2370-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To assess the usefulness of gemstone spectral imaging (GSI) dual-energy CT (DECT) with/without metal artefact reduction software (MARs). Methods The DECTs were performed using fast kV-switching GSI between 80 and 140 kV. The CT data were retro-reconstructed with/without MARs, by different displayed fields-of-view (DFOV), and with synthesised monochromatic energy in the range 40-140 keV. A phantom study of size and CT numbers was performed in a titanium plate and a stainless steel plate. A clinical study was performed in 26 patients with metallic hardware. All images were retrospectively reviewed in terms of the visualisation of periprosthetic regions and the severity of beam-hardening artefacts by using a five-point scale. Results The GSI-MARs reconstruction can markedly reduce the metal-related artefacts, and the image quality was affected by the prosthesis composition and DFOV. The spectral CT numbers of the prosthesis and periprosthetic regions showed different patterns on stainless steel and titanium plates. Conclusion Dual-energy CT with GSI-MARs can reduce metal-related artefacts and improve the delineation of the prosthesis and periprosthetic region. We should be cautious when using GSI-MARs because the image quality was affected by the prosthesis composition, energy (in keV) and DFOV. The metallic composition and size should be considered in metallic imaging with GSI-MARs reconstruction. Key Points Metal-related artefacts can be troublesome on musculoskeletal computed tomography (CT). Gemstone spectral imaging (GSI) with dual-energy CT (DECT) offers a novel solution GSI and metallic artefact reduction software (GSI-MAR) can markedly reduce these artefacts. However image quality is influenced by the prosthesis composition and other parameters. We should be aware about potential overcorrection when using GSI-MARs.
引用
收藏
页码:1331 / 1340
页数:10
相关论文
共 50 条
  • [21] Metal artefact reduction for accurate tumour delineation in radiotherapy
    Kovacs, David Gergely
    Rechner, Laura A.
    Appelt, Ane L.
    Berthelsen, Anne K.
    Costa, Junia C.
    Friborg, Jeppe
    Persson, Gitte F.
    Bangsgaard, Jens Peter
    Specht, Lena
    Aznar, Marianne C.
    RADIOTHERAPY AND ONCOLOGY, 2018, 126 (03) : 479 - 486
  • [22] Dual-energy CT with virtual monochromatic images and metal artifact reduction software for reducing metallic dental artifacts
    Cha, Jihoon
    Kim, Hyung-Jin
    Kim, Sung Tae
    Kim, Yi Kyung
    Kim, Ha Youn
    Park, Gyeong Min
    ACTA RADIOLOGICA, 2017, 58 (11) : 1312 - 1319
  • [23] Reduction of metal artifacts from unilateral hip arthroplasty on dual-energy CT with metal artifact reduction software
    Yue, Dong
    Rong, Cheng Fan
    Ning, Cai
    Liang, Hu
    Lian, Liu Ai
    Xin, Wang Ru
    Hong, Luo Ya
    ACTA RADIOLOGICA, 2018, 59 (07) : 853 - 860
  • [24] Metal artefact reduction in CT imaging of hip prostheses-an evaluation of commercial techniques provided by four vendors
    Andersson, K. M.
    Nowik, P.
    Persliden, J.
    Thunberg, P.
    Norrman, E.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1052)
  • [25] Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT
    Gong, X-Y
    Meyer, E.
    Yu, X-J
    Sun, J-H
    Sheng, L-P
    Huang, K-H
    Wu, R-Z
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (04)
  • [26] Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
    Ghafarian, Pardis
    Aghamiri, S. M. R.
    Ay, Mohammad R.
    Rahmim, Arman
    Schindler, Thomas H.
    Ratib, Osman
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (02) : 252 - 262
  • [27] Single-energy metal artefact reduction with CT for carbon-ion radiation therapy treatment planning
    Miki, Kentaro
    Mori, Shinichiro
    Hasegawa, Azusa
    Naganawa, Kensuke
    Koto, Masashi
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1062)
  • [28] Metal artefact reduction in low-dose computed tomography: Benefits of tin prefiltration versus postprocessing of dual-energy datasets over conventional CT imaging
    Huflage, H.
    Grunz, J-P
    Hackenbroch, C.
    Halt, D.
    Luetkens, K. S.
    Schmidt, A. M. Alfred
    Patzer, T. S.
    Ergun, S.
    Bley, T. A.
    Kunz, A. S.
    RADIOGRAPHY, 2022, 28 (03) : 690 - 696
  • [29] Value of monoenergetic dual-energy CT (DECT) for artefact reduction from metallic orthopedic implants in post-mortem studies
    Filograna, Laura
    Magarelli, Nicola
    Leone, Antonio
    Guggenberger, Roman
    Winklhofer, Sebastian
    Thali, Michael John
    Bonomo, Lorenzo
    SKELETAL RADIOLOGY, 2015, 44 (09) : 1287 - 1294
  • [30] A study of metal artefact reduction for industrial X-ray CT system with limited radiation energy
    Yu, Wei
    Zeng, Li
    Yang, Xiangyu
    INSIGHT, 2014, 56 (02) : 69 - 74