Fractal signature and lacunarity in the measurement of the texture of trabecular bone in clinical CT images

被引:72
作者
Dougherty, G
Henebry, GM
机构
[1] Kuwait Univ, Fac Allied Hlth Sci, Dept Radiol Sci, Sulibikhat, Kuwait
[2] Univ Nebraska, Ctr Adv Land Management Informat Technol, Lincoln, NE 68588 USA
关键词
texture; fractal dimension; fractal signature; lacunarity; bone architecture;
D O I
10.1016/S1350-4533(01)00057-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fractal analysis is a method of characterizing complex shapes such as the trabecular structure of bone. Numerous algorithms for estimating fractal dimension have been described, but the Fourier power spectrum method is particularly applicable to self-affine fractals, and facilitates corrections for the effects of noise and blurring in an image. We found that it provided accurate estimates of fractal dimension for synthesized fractal images. For natural texture images fractality is limited to a range of scales, and the fractal dimension as a function of spatial frequency presents as a fractal signature. We found that the fractal signature was more successful at discriminating between these textures than either the global fractal dimension or other metrics such as the mean width and root-mean-square width of the spectral density plots. Different natural textures were also readily distinguishable using lacunarity plots, which explicitly characterize the average size and spatial organization of structural sub-units within an image. The fractal signatures of small regions of interest (32x32 pixels), computed in the frequency domain after corrections for imaging system noise and MTF, were able to characterize the texture of vertebral trabecular bone in CT images. Even small differences in texture due to acquisition slice thickness resulted in measurably different fractal signatures. These differences were also readily apparent in lacunarity plots, which indicated that a slice thickness of I turn or less is necessary if essential architectural information is not to be lost. Since lacunarity measures gap size and is not predicated on fractality, it may be particularly useful for characterizing the texture of trabecular bone. (C) 2001 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:369 / 380
页数:12
相关论文
共 53 条
[1]   CHARACTERIZING THE LACUNARITY OF RANDOM AND DETERMINISTIC FRACTAL SETS [J].
ALLAIN, C ;
CLOITRE, M .
PHYSICAL REVIEW A, 1991, 44 (06) :3552-3558
[2]  
Brodatz P, 1966, TEXTURES PHOTOGRAPHI
[3]   FRACTAL SIGNATURE ANALYSIS OF MACRORADIOGRAPHS MEASURES TRABECULAR ORGANIZATION IN LUMBAR VERTEBRAE OF POSTMENOPAUSAL WOMEN [J].
BUCKLANDWRIGHT, JC ;
LYNCH, JA ;
RYMER, J ;
FOGELMAN, I .
CALCIFIED TISSUE INTERNATIONAL, 1994, 54 (02) :106-112
[4]   COMPUTERIZED RADIOGRAPHIC ANALYSIS OF OSTEOPOROSIS - PRELIMINARY EVALUATION [J].
CALIGIURI, P ;
GIGER, ML ;
FAVUS, MJ ;
JIA, H ;
DOI, K ;
DIXON, LB .
RADIOLOGY, 1993, 186 (02) :471-474
[5]   QUANTITATIVE CT FOR DETERMINATION OF BONE-MINERAL DENSITY - A REVIEW [J].
CANN, CE .
RADIOLOGY, 1988, 166 (02) :509-522
[6]   ON THE FRACTAL NATURE OF TRABECULAR STRUCTURE [J].
CHUNG, HW ;
CHU, CC ;
UNDERWEISER, M ;
WEHRLI, FW .
MEDICAL PHYSICS, 1994, 21 (10) :1535-1540
[7]   Test of a new lacunarity estimation method for image texture analysis [J].
Dong, P .
INTERNATIONAL JOURNAL OF REMOTE SENSING, 2000, 21 (17) :3369-3373
[8]   A comparison of the texture of computed tomography and projection radiography images of vertebral trabecular bone using fractal signature and lacunarity [J].
Dougherty, G .
MEDICAL ENGINEERING & PHYSICS, 2001, 23 (05) :313-321
[9]   Measurement of thickness and density of thin structures by computed tomography: A simulation study [J].
Dougherty, G ;
Newman, D .
MEDICAL PHYSICS, 1999, 26 (07) :1341-1348
[10]   EVALUATING THE FRACTAL DIMENSION OF SURFACES [J].
DUBUC, B ;
ZUCKER, SW ;
TRICOT, C ;
QUINIOU, JF ;
WEHBI, D .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1989, 425 (1868) :113-127