The Effect of Photon Energy Weighting on X-ray Imaging Based on a Photon Counting Detector

被引:5
|
作者
Choi, Yu-Na
Lee, Seung-Wan
Cho, Hyo-Min
Ryu, Hyun-Ju
Lee, Young-Jin
Kim, Hee-Joung [1 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
基金
新加坡国家研究基金会;
关键词
Photon energy weighting; GATE; CNR; MONTE-CARLO-SIMULATION; DIGITAL MAMMOGRAPHY; GATE; PLATFORM; PET; CT;
D O I
10.3938/jkps.59.3114
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Development of photon counting detectors with the ability of energy discrimination would provide additional information. These detectors could improve the contrast-to-noise ratio (CNR) by using photon energy weighting with energy-dependent weighting factors. The purpose of this study was to evaluate the effect of photon energy weighting using GEANT4 Application for Tomographic Emission (GATE) version 6.0. The photon energy weighting depends on the X-ray attenuation coefficient of contrast elements and background materials. In this study, we simulated a photon counting X-ray imaging system. We designed a cadmium telluride (CdTe) photon counting detector (model PID-350, AJAT, Finland), the micro focus X-ray source (model L8601-01, Hamamatsu, Japan) and two phantoms with GATE. In the first case, we were concerned with calcifications in breast tissue or soft tissue. We defined a cubic phantom made of poly (methyl methacrylate) (PMMA) material with a thickness of 40 mm including four CaCO3 contrast elements with different thickness of 1.0, 3.0, 5.0, and 7.0 mm. In the second case, we designed a second phantom for contrast-enhanced digital mammography (CEDM). We defined two cylindrical phantoms made of PMMA with thicknesses of 30 and 40 mm, including four iodine contrast elements with different thicknesses of 0.3, 0.5, 1.0, and 1.5 mm. The effect of photon energy weighting was investigated in terms of the CNR. In all cases, photon energy weighting improve the CNR. The CNR improvements for CaCO3 with thicknesses of 1.0, 3.0, 5.0, and 7.0 mm were 1.41, 1.32, 1.43, and 1.56, respectively. For the second phantom with a thickness of 30 mm, the CNR improvements of iodine contrast elements with thicknesses of 1.0, 3.0, 5.0, and 7.0 mm were 1.01, 1.03, 1.09, and 1.13, respectively, and for the second phantom with a thicknesses of 40 mm, the CNR improvements of iodine contrast elements with thickness of 1.0, 3.0, 5.0, and 7.0 mm were 1.05, 1.07, 1.16, and 1.10, respectively. This study demonstrates that the photon energy weighting using additional information improves the CNR, which allows better detection of calcium, a contrast agent or other contrast elements.
引用
收藏
页码:3114 / 3119
页数:6
相关论文
共 50 条
  • [21] Identification of amyloid plaques in the brain using an x-ray photon-counting strip detector
    Ghammraoui, Bahaa
    Badano, Aldo
    PLOS ONE, 2020, 15 (02):
  • [22] Vision 20/20: Single photon counting x-ray detectors in medical imaging
    Taguchi, Katsuyuki
    Iwanczyk, Jan S.
    MEDICAL PHYSICS, 2013, 40 (10) : 100901
  • [23] Material separation in x-ray CT with energy resolved photon-counting detectors
    Wang, Xiaolan
    Meier, Dirk
    Taguchi, Katsuyuki
    Wagenaar, Douglas J.
    Patt, Bradley E.
    Frey, Eric C.
    MEDICAL PHYSICS, 2011, 38 (03) : 1534 - 1546
  • [24] Material Separation in X-ray CT with Energy Resolved Photon-Counting Detectors
    Wang, X.
    Meier, D.
    Taguchi, K.
    Wagenaar, D. J.
    Patt, B. E.
    Frey, E. C.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [25] Pulse Temporal Splitting in Photon Counting X-Ray Detectors
    Engel, Klaus Jurgen
    Steadman, Roger
    Herrmann, Christoph
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1480 - 1490
  • [26] Imaging performance of a LaBr3:Ce scintillation detector for photon counting x-ray computed tomography: Simulation study
    Taguchi, Katsuyuki
    Schaart, Dennis R.
    Goorden, Marlies C.
    Hsieh, Scott S.
    MEDICAL PHYSICS, 2024,
  • [27] Optimization of energy windows to calculate quantitative X-ray images using an energy-resolving photon-counting detector: A simulation study
    Nishigami, Rina
    Kobayashi, Daiki
    Kimoto, Natsumi
    Asahara, Takashi
    Maeda, Tatsuya
    Haba, Tomonobu
    Kanazawa, Yuki
    Yamamoto, Shuichiro
    Hayashi, Hiroaki
    RADIATION PHYSICS AND CHEMISTRY, 2025, 229
  • [28] Energy Calibration of a Silicon-Strip Detector for Photon-Counting Spectral CT by Direct Usage of the X-ray Tube Spectrum
    Liu, Xuejin
    Chen, Han
    Bornefalk, Hans
    Danielsson, Mats
    Karlsson, Staffan
    Persson, Mats
    Xu, Cheng
    Huber, Ben
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 68 - 75
  • [29] Model and reconstruction of a K-edge contrast agent distribution with an X-ray photon-counting detector
    Meng, Bo
    Cong, Wenxiang
    Xi, Yan
    De Man, Bruno
    Yang, Jian
    Wang, Ge
    OPTICS EXPRESS, 2017, 25 (08): : 9378 - 9392
  • [30] Simultaneous X-ray fluorescence and K-edge CT imaging with photon-counting detectors
    Li, Liang
    Li, Ruizhe
    Zhang, Siyuan
    Chen, Zhiqiang
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967