The Effect of Photon Energy Weighting on X-ray Imaging Based on a Photon Counting Detector

被引:5
|
作者
Choi, Yu-Na
Lee, Seung-Wan
Cho, Hyo-Min
Ryu, Hyun-Ju
Lee, Young-Jin
Kim, Hee-Joung [1 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
基金
新加坡国家研究基金会;
关键词
Photon energy weighting; GATE; CNR; MONTE-CARLO-SIMULATION; DIGITAL MAMMOGRAPHY; GATE; PLATFORM; PET; CT;
D O I
10.3938/jkps.59.3114
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Development of photon counting detectors with the ability of energy discrimination would provide additional information. These detectors could improve the contrast-to-noise ratio (CNR) by using photon energy weighting with energy-dependent weighting factors. The purpose of this study was to evaluate the effect of photon energy weighting using GEANT4 Application for Tomographic Emission (GATE) version 6.0. The photon energy weighting depends on the X-ray attenuation coefficient of contrast elements and background materials. In this study, we simulated a photon counting X-ray imaging system. We designed a cadmium telluride (CdTe) photon counting detector (model PID-350, AJAT, Finland), the micro focus X-ray source (model L8601-01, Hamamatsu, Japan) and two phantoms with GATE. In the first case, we were concerned with calcifications in breast tissue or soft tissue. We defined a cubic phantom made of poly (methyl methacrylate) (PMMA) material with a thickness of 40 mm including four CaCO3 contrast elements with different thickness of 1.0, 3.0, 5.0, and 7.0 mm. In the second case, we designed a second phantom for contrast-enhanced digital mammography (CEDM). We defined two cylindrical phantoms made of PMMA with thicknesses of 30 and 40 mm, including four iodine contrast elements with different thicknesses of 0.3, 0.5, 1.0, and 1.5 mm. The effect of photon energy weighting was investigated in terms of the CNR. In all cases, photon energy weighting improve the CNR. The CNR improvements for CaCO3 with thicknesses of 1.0, 3.0, 5.0, and 7.0 mm were 1.41, 1.32, 1.43, and 1.56, respectively. For the second phantom with a thickness of 30 mm, the CNR improvements of iodine contrast elements with thicknesses of 1.0, 3.0, 5.0, and 7.0 mm were 1.01, 1.03, 1.09, and 1.13, respectively, and for the second phantom with a thicknesses of 40 mm, the CNR improvements of iodine contrast elements with thickness of 1.0, 3.0, 5.0, and 7.0 mm were 1.05, 1.07, 1.16, and 1.10, respectively. This study demonstrates that the photon energy weighting using additional information improves the CNR, which allows better detection of calcium, a contrast agent or other contrast elements.
引用
收藏
页码:3114 / 3119
页数:6
相关论文
共 50 条
  • [1] The effect of energy weighting on x-ray imaging based on photon counting detector: a Monte Carlo simulation
    Lee, Seung-Wan
    Choi, Yu-Na
    Cho, Hyo-Min
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Kim, Hee-Joung
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [2] The Effects of Spectral Distortion on Multi-Energy X-ray Imaging Based on Photon Counting Detector
    Cho, Hyo-Min
    Choi, Yu-Na
    Lee, Seung-Wan
    Ryu, Hyun-Ju
    Lee, Young-Jin
    Kim, Hee-Joung
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3001 - 3003
  • [3] The effects of photon flux on energy spectra and imaging characteristics in a photon-counting x-ray detector
    Cho, H-M
    Kim, H-J
    Choi, Y-N
    Lee, S-W
    Ryu, H-J
    Lee, Y-J
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (14): : 4865 - 4879
  • [4] Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detector
    Shikhaliev, Polad M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (16): : 4971 - 4992
  • [5] Experimental characterization of an X-ray photon counting detector
    Wang, X.
    Wei, T.
    Deng, Z.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (07)
  • [6] Image quality assessment of a photon counting detector in X-ray projection imaging
    Ghani, Muhammad U.
    Li, Yuhua
    Wu, Xizeng
    Liu, Hong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 939 : 83 - 88
  • [7] Evaluation and comparison of a CdTe based photon counting detector with an energy integrating detector for X-ray phase sensitive imaging of breast cancer
    Ghani, Muhammad U.
    Omoumi, Farid H.
    Wu, Xizeng
    Fajardo, Laurie L.
    Zheng, Bin
    Liu, Hong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (02) : 207 - 219
  • [8] Task-based weights for photon counting spectral x-ray imaging
    Bornefalk, Hans
    MEDICAL PHYSICS, 2011, 38 (11) : 6065 - 6073
  • [9] Analysis of artifact with X-ray CT using energy band by photon counting CdTe detector
    Matsumoto, G.
    Imura, Y.
    Morii, H.
    Miyake, A.
    Aoki, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 292 - 294
  • [10] Practical energy response estimation of photon counting detectors for spectral X-ray imaging
    Kang, Dong-Goo
    Lee, Jongha
    Sung, Younghun
    Lee, SeongDeok
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622