Contrast-detail analysis characterizing diffuse optical fluorescence tomography image reconstruction

被引:46
作者
Davis, SC [1 ]
Pogue, BW [1 ]
Dehghani, H [1 ]
Paulsen, KD [1 ]
机构
[1] Thayer Sch Engn, Dartmouth Coll, Hanover, NH 03755 USA
关键词
D O I
10.1117/1.2114727
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Contrast-detail analysis is used to evaluate the imaging performance of diffuse optical fluorescence tomography (DOFT), characterizing spatial resolution limits, signal-to-noise limits, and the trade-off between object contrast and size. Reconstructed images of fluorescence yield from simulated noisy data were used to determine the contrast-to-noise ratio (CNR). A threshold of CNR=3 was used to approximate a lowest acceptable noise level in the image, as a surrogate measure for human detection of objects. For objects 0.5 cm inside the edge of a simulated tissue region, the smallest diameter that met this criteria was approximately 1.7 mm, regardless of contrast level, and test field diameter had little impact on this limit. Object depth had substantial impact on object CNR, leading to a limit of 4 mm for objects near the center of a 51-mm test field and 8.5 mm for an 86-mm test field. Similarly, large objects near the edge of both test fields required a minimum contrast of 50% to achieve acceptable image CNR. The minimum contrast for large, centered objects ranged between 50% and 100%. Contrast-detail analysis using human detection of lower contrast limits provides fundamentally important information about the performance of reconstruction algorithms, and can be used to compare imaging performance of different systems. (c) 2005 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:3
相关论文
共 16 条
  • [1] CONTRAST-DETAIL-DOSE ANALYSIS OF 6 DIFFERENT COMPUTED TOMOGRAPHIC SCANNERS
    COHEN, G
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (02) : 197 - 203
  • [2] Three-dimensional, Bayesian image reconstruction from sparse and noisy data sets: Near-infrared fluorescence tomography
    Eppstein, MJ
    Hawrysz, DJ
    Godavarty, A
    Sevick-Muraca, EM
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (15) : 9619 - 9624
  • [3] A submillimeter resolution fluorescence molecular imaging system for small animal imaging
    Graves, EE
    Ripoll, J
    Weissleder, R
    Ntziachristos, V
    [J]. MEDICAL PHYSICS, 2003, 30 (05) : 901 - 911
  • [4] Developments toward diagnostic breast cancer imaging using near-infrared optical measurements and fluorescent contrast agents
    Hawrysz, DJ
    Sevick-Muraca, EM
    [J]. NEOPLASIA, 2000, 2 (05): : 388 - 417
  • [5] HENDRICK R, 1999, RSNA CATEGORICAL COU
  • [6] Adaptive finite element based tomography for fluorescence optical imaging in tissue
    Joshi, A
    Bangerth, W
    Sevick-Muraca, EM
    [J]. OPTICS EXPRESS, 2004, 12 (22): : 5402 - 5417
  • [7] A parallel-detection frequency-domain near-infrared tomography system for hemoglobin imaging of the breast in vivo
    McBride, TO
    Pogue, BW
    Jiang, S
    Osterberg, UL
    Paulsen, KD
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (03) : 1817 - 1824
  • [8] Fluorescence optical diffusion tomography
    Milstein, AB
    Oh, S
    Webb, KJ
    Bouman, CA
    Zhang, Q
    Boas, DA
    Millane, RP
    [J]. APPLIED OPTICS, 2003, 42 (16) : 3081 - 3094
  • [9] Experimental three-dimensional fluorescence reconstruction of diffuse media by use of a normalized Born approximation
    Ntziachristos, V
    Weissleder, R
    [J]. OPTICS LETTERS, 2001, 26 (12) : 893 - 895
  • [10] Charge-coupled-device based scanner for tomography of fluorescent near-infrared probes in turbid media
    Ntziachristos, V