Evaluation of the Influence of Rotor Magnetic Anisotropy on Condition Monitoring of Two-Pole Induction Motors

被引:32
作者
Shin, Sungsik [1 ]
Kim, Jongwan [1 ]
Lee, Sang Bin [1 ]
Lim, Chaewoong [2 ]
Wiedenbrug, Ernesto J. [3 ]
机构
[1] Korea Univ, Dept Elect Engn, Seoul 136701, South Korea
[2] Hansung Elect Ind Co, Dangjin 343844, South Korea
[3] Wiedenbrug LLC, Ft Collins, CO 80528 USA
基金
新加坡国家研究基金会;
关键词
AC machines; false alarm; fault diagnosis; frequency-domain analysis; induction motors; motor current signature analysis (MCSA); predictive maintenance; rotor fault; DIAGNOSIS; MACHINES; BAR;
D O I
10.1109/TIA.2015.2391432
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
If nongrain-oriented rotor laminations are punched and stacked in a uniform direction, magnetic asymmetry is present in the rotor core due to the nonideal magnetic anisotropy. In this paper, it is shown that the influence of rotor core anisotropy can be misinterpreted as rotor faults in two-pole induction motors when performing motor current signature analysis. A detailed analysis of the influence of rotor core anisotropy shows that components produced by the rotor fault and rotor anisotropy interact, making reliable fault detection difficult. It is also shown that offline testing is currently the only available means of detecting the fault, and online monitoring of the space harmonics-induced current components is proposed as a viable solution for providing reliable rotor fault detection for two-pole motors with rotor anisotropy. The analysis and conclusions presented in this paper are verified through testing on custom-built lab motors and on 3.3-kV motors.
引用
收藏
页码:2896 / 2904
页数:9
相关论文
共 50 条
[41]   A simple fuzzy logic approach for induction motors stator condition monitoring [J].
Benbouzid, MEH ;
Nejjari, H .
IEMDC 2001: IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, 2001, :634-639
[42]   Rotor Bar Fault Monitoring Method Based on Analysis of Air-Gap Torques of Induction Motors [J].
da Silva, Aderiano M. ;
Povinelli, Richard J. ;
Demerdash, Nabeel A. O. .
IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2013, 9 (04) :2274-2283
[43]   Detection of Rotor Electrical Faults in Induction Motors during the Start-up via Torque Monitoring [J].
Gyftakis, Konstantinos N. ;
Palomeno, Enrico ;
Spyropoulos, Dionysios V. ;
Mitronikas, Epaminondas D. .
45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, :3673-3678
[44]   Extraction of Frequency Information for the Reliable Screening of Rotor Electrical Faults Via Torque Monitoring in Induction Motors [J].
Spyropoulos, Dionysios, V ;
Panagiotou, Panagiotis A. ;
Arvanitakis, Ioannis ;
Mitronikas, Epaminondas D. ;
Gyftakis, Konstantinos N. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2021, 57 (06) :5949-5958
[45]   A Novel Bearing Condition Monitoring Method in Induction Motors Based on Instantaneous Frequency of Motor Voltage [J].
Dalvand, Fardin ;
Kalantar, Asadollah ;
Safizadeh, Mir Saeed .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (01) :364-376
[46]   Induction Motor Rotor Bar Damage Evaluation With Magnetic Field Analysis [J].
Clark, Scott W. ;
Stevens, Daniel .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (02) :1469-1476
[47]   Induction Motor Rotor Bar Damage Evaluation with Magnetic Field Analysis [J].
Clark, Scott W. ;
Stevens, Daniel .
2015 IEEE 10TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2015, :39-43
[48]   The Influence of the Broken Bar Fault on the Magnetic Field and Electromagnetic Torque in 3-phase Induction Motors [J].
Spyropoulos, Dionysios V. ;
Gyftakis, Konstantinos N. ;
Kappatou, Joya ;
Mitronikas, Epaminondas D. .
2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2012, :1868-1874
[49]   Recent Experiences with MCSA and Flux Condition Monitoring of Mechanical Faults in 6kV Induction Motors for Water Pumping Applications [J].
Gyftakis, Konstantinos N. ;
Panagiotou, Panagiotis A. ;
Spyrakis, Dimitrios .
PROCEEDINGS OF THE 2019 IEEE 12TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2019, :214-219
[50]   Assessment of the rotor condition in soft-started induction motors through the Hilbert transform of transient stray flux signals [J].
Biot-Monterde, Vicente ;
Navarro-Navarro, Angela ;
Zamudio-Ramirez, Israel ;
Antonino-Daviu, Jose A. ;
Osornio-Rios, Roque A. .
2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,