4D Flow MRI in Ascending Aortic Aneurysms: Reproducibility of Hemodynamic Parameters

被引:1
|
作者
Juffermans, Joe F. [1 ]
van Assen, Hans C. [1 ]
te Kiefte, Bastiaan J. C. [1 ]
Ramaekers, Mitch J. F. G. [1 ,2 ,3 ,4 ]
van der Palen, Roel L. F. [5 ]
van den Boogaard, Pieter [1 ]
Adriaans, Bouke P. [2 ,3 ,4 ]
Wildberger, Joachim E. [3 ,4 ]
Dekkers, Ilona A. [1 ]
Scholte, Arthur J. H. A. [6 ]
Schalla, Simon [2 ,3 ,4 ]
Lamb, Hildo J. [1 ]
Westenberg, Jos J. M. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Cardiol, NL-6229 HX Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, NL-6229 HX Maastricht, Netherlands
[4] Cardiovasc Res Inst Maastricht, NL-6229 HX Maastricht, Netherlands
[5] Leiden Univ, Med Ctr, Dept Pediat, Div Pediat Cardiol, NL-2333 ZA Leiden, Netherlands
[6] Leiden Univ, Med Ctr, Dept Cardiol, NL-2333 ZA Leiden, Netherlands
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 08期
关键词
aorta; aneurysm; hemodynamic; 4D flow MRI; reproducibility; WALL SHEAR-STRESS; VALVE; QUANTIFICATION; ACCURACY; DIAMETER; PATTERNS; VELOCITY; SIZE;
D O I
10.3390/app12083912
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
(1) Background: Aorta hemodynamics have been associated with aortic remodeling, but the reproducibility of its assessment has been evaluated marginally in patients with thoracic aortic aneurysm (TAA). The current study evaluated intra- and interobserver reproducibility of 4D flow MRI-derived hemodynamic parameters (normalized flow displacement, flow jet angle, wall shear stress (WSS) magnitude, axial WSS, circumferential WSS, WSS angle, vorticity, helicity, and local normalized helicity (LNH)) in TAA patients; (2) Methods: The thoracic aorta of 20 patients was semi-automatically segmented on 4D flow MRI data in 5 systolic phases by 3 different observers. Each time-dependent segmentation was manually improved and partitioned into six anatomical segments. The hemodynamic parameters were quantified per phase and segment. The coefficient of variation (COV) and intraclass correlation coefficient (ICC) were calculated; (3) Results: A total of 2400 lumen segments were analyzed. The mean aneurysm diameter was 50.8 +/- 2.7 mm. The intra- and interobserver analysis demonstrated a good reproducibility (COV = 16-30% and ICC = 0.84-0.94) for normalized flow displacement and jet angle, a very good-to-excellent reproducibility (COV = 3-26% and ICC = 0.87-1.00) for all WSS components, helicity and LNH, and an excellent reproducibility (COV = 3-10% and ICC = 0.96-1.00) for vorticity; (4) Conclusion: 4D flow MRI-derived hemodynamic parameters are reproducible within the thoracic aorta in TAA patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] 4D flow MRI
    Markl, Michael
    Frydrychowicz, Alex
    Kozerke, Sebastian
    Hope, Mike
    Wieben, Oliver
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (05) : 1015 - 1036
  • [32] Aortic Flow Patterns and Peak Velocity Assessment Using 4D Flow MRI in Dilated Ascending Aorta With and Without Aortic Valve Stenosis and Regurgitation
    Suwa, Kenichiro
    Rahman, Ozair A.
    Bollache, Emilie
    Rose, Michael J.
    Rahsepar, Amir A.
    Hayashi, Hideharu
    Carr, James
    Collins, Jeremy
    Barker, Alex
    Markl, Michael
    CIRCULATION, 2016, 134
  • [33] Editorial for "Reproducibility of Aorta Segmentation on 4D Flow MRI in Healthy Volunteers"
    Wentland, Andrew L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (04) : 1280 - 1281
  • [34] Fully automated 3D aortic segmentation of 4D flow MRI for hemodynamic analysis using deep learning
    Berhane, Haben
    Scott, Michael
    Elbaz, Mohammed
    Jarvis, Kelly
    McCarthy, Patrick
    Carr, James
    Malaisrie, Chris
    Avery, Ryan
    Barker, Alex J.
    Robinson, Joshua D.
    Rigsby, Cynthia K.
    Markl, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (04) : 2204 - 2218
  • [35] Identification of Vortex Cores in Cerebral Aneurysms on 4D Flow MRI REPLY
    Futami, K.
    Misaki, K.
    Nakada, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (05) : E27 - E27
  • [36] Accelerated aortic 4D flow MRI with wave-CAIPI
    Richter, Julian A. J.
    Wech, Tobias
    Weng, Andreas M.
    Stich, Manuel
    Jin, Ning
    Kosmala, Aleksander
    Bley, Thorsten A.
    Kostler, Herbert
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (05) : 2595 - 2607
  • [37] A clinician’s guide to understanding aortic 4D flow MRI
    Mitch J. F. G. Ramaekers
    Jos J. M. Westenberg
    Bouke P. Adriaans
    Estelle C. Nijssen
    Joachim E. Wildberger
    Hildo J. Lamb
    Simon Schalla
    Insights into Imaging, 14
  • [38] Clinical use of 4D flow MRI for quantification of aortic regurgitation
    Alvarez, Ana
    Martinez, Vicente
    Pizarro, Gonzalo
    Recio, Manuel
    Angel Cabrera, Jose
    OPEN HEART, 2020, 7 (01):
  • [39] A clinician's guide to understanding aortic 4D flow MRI
    Ramaekers, Mitch J. F. G.
    Westenberg, Jos J. M.
    Adriaans, Bouke P.
    Nijssen, Estelle C.
    Wildberger, Joachim E.
    Lamb, Hildo J.
    Schalla, Simon
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [40] A practical introduction to the hemodynamic analysis of the cardiovascular system with 4D Flow MRI
    Pineda Zapata, J. A.
    Delgado de Bedouta, J. A.
    Rascovsky Ramireza, S.
    Bustamante, C.
    Mesa, S.
    Calvo Betancur, V. D.
    RADIOLOGIA, 2014, 56 (06): : 485 - 495