Determining water quality parameters of aquifers in the Vientiane Basin, Laos, using geophysical and water chemistry data

被引:12
|
作者
Perttu, Nils [1 ]
Wattanasen, Kamhaeng [2 ]
Phommasone, Khamphouth [3 ]
Elming, Sten-Ake [1 ]
机构
[1] Lulea Univ Technol, Div Ore Geol & Appl Geophys, S-97187 Lulea, Sweden
[2] Prince Songkla Univ, Dept Phys, Fac Sci, Haya 90112, Thailand
[3] Natl Univ Laos, Dept Phys, Viangchan, Laos
关键词
CORRELATING SPECIFIC CONDUCTIVITY; MAGNETIC-RESONANCE; TOTAL HARDNESS; MRS;
D O I
10.3997/1873-0604.2011014
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The aim of this study is to test the possibility of using magnetic resonance sounding (MRS) and vertical electrical sounding (VES) together with groundwater chemistry data from shallow and deep wells to distinguish freshwater aquifers from salt affected groundwater and moreover determine water quality parameters directly from geophysical data. Three study areas within the Vientiane Basin, including 46 sites and 38 sampled wells, have been chosen for the study. The main water quality parameters affecting the water conductivity in the Vientiane Basin are total dissolved solids (TDS) and hardness and to a minor extent chloride, which all have shown to have fairly high correlation to the electrical conductivity (EC) of groundwater. The resistivity of the aquifers is highly variable but is most often above 4 Omega m, suggesting fresh water. No wells in the investigated areas have water quality parameters exceeding the limit for unacceptable drinking or irrigation water. There is a fairly strong relationship between the conductivity of water from deep wells and the conductivity of the main water bearing layer determined by VES, where the best fit is obtained using: EC[mu S/cm] = 0.4694VES[mu S/cm], R-2=0.69. However, due to equivalence in the VES interpretation and the difficulty to estimate the resistivity contribution from finer sediments, the equation may be seen and used as guidance to good water quality only within the Vientiane Basin area or in other areas with similar geology. The MRS results have been used to identify water layers in the VES inversion results to decrease the uncertainty in the interpretation The combination of MRS and VES techniques has been successful in distinguishing high conductive clay and mudstone from water bearing layers and moreover freshwater aquifers from salt affected water. Altogether, this makes MRS and VES very promising tools for guidance of future drilling and water quality estimation.
引用
收藏
页码:381 / 395
页数:15
相关论文
共 50 条
  • [21] Delineating saline and fresh water aquifers in Tuticorin of southern India by using geophysical techniques
    Sekar, Selvam
    Kamaraj, Jesuraja
    Senapathi, Venkatramanan
    Sabarathinam, Chidambaram
    Viswanathan, Prasanna Mohan
    Karthikeyan, Sivakumar
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2021, 23 (12) : 17723 - 17744
  • [22] DETERMINING THE QUALITY OF SURFACE-WATER USING MULTIBAND AEROSPACE VIDEO DATA
    GITELSON, AA
    KEIDAN, GP
    SHISHKIN, VN
    SOVIET JOURNAL OF REMOTE SENSING, 1989, 5 (06): : 1038 - 1051
  • [23] Modeling of Water Quality Parameters Using Data-Driven Models
    Orouji, H.
    Bozorg-Haddad, Omid
    Fallah-Mehdipour, E.
    Marino, M. A.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2013, 139 (07) : 947 - 957
  • [24] Assessment of chemical denudation rates using hydrological measurements, water chemistry analysis and electromagnetic geophysical data
    Beylich, AA
    Kolstrup, E
    Linde, N
    Pedersen, LB
    Thyrsted, T
    Gintz, D
    Dynesius, L
    PERMAFROST AND PERIGLACIAL PROCESSES, 2003, 14 (04) : 387 - 397
  • [25] Monitoring Water Quality Parameters Using Sentinel-2 Data: A Case Study in the Weihe River Basin (China)
    Liu, Tieming
    Guo, Zhao
    Li, Xiaoping
    Xiao, Teng
    Liu, Jiaxin
    Zhang, Yuanzhi
    SUSTAINABILITY, 2024, 16 (16)
  • [26] Thick-film multisensor for determining water quality parameters
    Breijo, EG
    Sanchez, LG
    Civera, JL
    IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 2791 - 2796
  • [27] Assessment of water quality parameters using multivariate analysis for Klang River basin, Malaysia
    Ibrahim Mohamed
    Faridah Othman
    Adriana I. N. Ibrahim
    M. E. Alaa-Eldin
    Rossita M. Yunus
    Environmental Monitoring and Assessment, 2015, 187
  • [28] Assessment of water quality parameters using multivariate analysis for Klang River basin, Malaysia
    Mohamed, Ibrahim
    Othman, Faridah
    Ibrahim, Adriana I. N.
    Alaa-Eldin, M. E.
    Yunus, Rossita M.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2015, 187 (01) : 1 - 12
  • [29] Water quality in shallow alluvial aquifers, upper Colorado River Basin, Colorado, 1997
    Apodaca, LE
    Bails, JB
    Smith, CM
    JOURNAL OF THE AMERICAN WATER RESOURCES ASSOCIATION, 2002, 38 (01): : 133 - 149
  • [30] Evaluating Drinking Water Quality Using Water Quality Parameters and Esthetic Attributes
    Addisie, Meseret B.
    AIR SOIL AND WATER RESEARCH, 2022, 15