An OH-PDMS-Modified Nano-Silica/Carbon Hybrid Coating for Anti-Icing of Insulators Part II: Anti-Icing Performance

被引:11
作者
Yan, Xinzhu [1 ]
Li, Jian [1 ]
Li, Licheng [2 ]
Huang, Zhengyong [1 ]
Hu, Jianlin [1 ]
Lu, Ming [3 ]
机构
[1] Chongqing Univ, Sch Elect Engn, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] China Southern Power Grid, Guangzhou 510000, Guangdong, Peoples R China
[3] State Grid Henan Elect Power Co, Zhengzhou 450052, Peoples R China
基金
中国国家自然科学基金;
关键词
Insulator; coating; semi-conducting; super-hydrophobic; anti-icing; electrothermal effect; AC FLASHOVER PERFORMANCE; ICE; CONFIGURATION;
D O I
10.1109/TDEI.2016.7556491
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Icing on insulators affects seriously the operation safety of high voltage transmission lines. Super-hydrophobic and semi-conducting coatings show anti-icing potential for insulators on transmission lines. By combining super-hydrophobicity and electrothermal effects, a hydroxy-terminated polydimethylsiloxane (OH-PDMS)-modified nano-silica/carbon hybrid coating was developed to solve the problem of insulator icing. The anti-icing performance of insulators coated with OH-PDMS-modified nanosilica/carbon hybrid coating were investigated. Leakage current, temperature distribution, ice morphology, icicle length, and flashover voltage of the insulators are presented. Both the electric and the thermal field distributions were analyzed to verify anti-icing performance of the coating. Experimental results show that the joule heat generated by the coating increases the insulator surface temperature, and the OH-PDMS-modified nano-silica/carbon hybrid coating has a superior performance to super-hydrophobic coating in terms of reducing ice accretion and improving flashover voltage of insulators.
引用
收藏
页码:2165 / 2173
页数:9
相关论文
共 32 条
[11]  
Farzaneh M., 2009, IEEE PRESS SERIES PO
[12]   An application of HVDC to the de-icing of transmission lines [J].
Horwill, C. ;
Davidson, C. C. ;
Granger, M. .
2005/2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2006, :529-534
[13]   Effects of Shed Configuration on AC Flashover Performance of Ice-covered Composite Long-rod Insulators [J].
Hu, Qin ;
Shu, Lichun ;
Jiang, Xingliang ;
Sun, Caixin ;
Zhang, Zhijin ;
Hu, Jianlin .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (01) :200-208
[14]   A dynamic programming methodology to develop de-icing strategies during ice storms by channeling load currents in transmission networks [J].
Huneault, M ;
Langheit, C ;
Arnaud, RS ;
Benny, J ;
Audet, J ;
Richard, JC .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) :1604-1610
[15]   DC Flashover Performance and Effect of Sheds Configuration on Polluted and Ice-covered Composite Insulators at Low Atmospheric Pressure [J].
Jiang, Xingliang ;
Chao, Yafeng ;
Zhang, Zhijin ;
Hu, Jianlin ;
Shu, Lichun .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (01) :97-105
[16]   Effect of Hydrophobicity Coating on Insulator Icing and DC Flashover Performance of Iced Insulators [J].
Jiang, Xingliang ;
Ma, Jun ;
Zhang, Zhijing ;
Hu, Jianlin .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (02) :351-359
[17]   Laboratory investigations of the electrical performance of ice-covered insulators and a metal oxide surge arrester [J].
Kannus, K. ;
Lahti, K. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) :1357-1372
[18]   How Wetting Hysteresis Influences Ice Adhesion Strength on Superhydrophobic Surfaces [J].
Kulinich, S. A. ;
Farzaneh, M. .
LANGMUIR, 2009, 25 (16) :8854-8856
[19]   State-of-the-art on power line de-icing [J].
Laforte, JL ;
Allaire, MA ;
Laflamme, J .
ATMOSPHERIC RESEARCH, 1998, 46 (1-2) :143-158
[20]   Anti-icing Performance of a Superhydrophobic PDMS/Modified Nano-silica Hybrid Coating for Insulators [J].
Li, Jian ;
Zhao, Yushun ;
Hu, Jianlin ;
Shu, Lichun ;
Shi, Xianming .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2012, 26 (4-5) :665-679