Moxifloxacin detection based on fluorescence resonance energy transfer from carbon quantum dots to moxifloxacin using a ratiometric fluorescence probe

被引:10
|
作者
Li, Zhiwen [1 ,2 ]
Zhang, Jiyue [1 ,2 ]
Sun, Qiyao [1 ,2 ]
Shi, Wenwen [1 ,2 ]
Tao, Tingxian [1 ,2 ]
Fu, Yingqiang [1 ,2 ]
机构
[1] Anhui Polytech Univ, Sch Chem & Environm Engn, Wuhu 241000, Anhui, Peoples R China
[2] Anhui Prov Key Lab Funct Coordinated Complexes Ma, Wuhu 241000, Anhui, Peoples R China
关键词
LIQUID-CHROMATOGRAPHY; CIPROFLOXACIN; TIO2;
D O I
10.1039/d1nj05961k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new method of ratiometric fluorescence detection of moxifloxacin (MOX) was developed based on carbon quantum dots (CQDs). Through a one-step hydrothermal method using soluble starch and acetic acid buffer solution as precursors, blue fluorescent CQDs with excitation wavelength-dependence were prepared. MOX could combine with CQDs to form a CQDs/MOX through hydrogen bonding. The absorption spectrum of CQDs/MOX and the fluorescence emission spectrum of CQDs overlapped to a certain extent, which allowed for fluorescence resonance energy transfer (FRET) formation between CQDs/MOX and CQDs. For MOX detection, as the MOX concentration increased, the intensity of the fluorescence emission peak of CQDs decreased gradually, the intensity of the fluorescence emission peak of CQDs/MOX increased gradually, and the fluorescence emission peaks of CQDs and CQDs/MOX both had a red-shift. Based on the FRET system between CQDs and CQDs/MOX, a new method for ratiometric fluorescence detection of MOX was established. This method was more effective for MOX detection in the concentration range 3.3 x 10(-7) to 2 x 10(-6) M. Our method had high sensitivity and selectivity, and the limit of detection was 2.59 nM. The recovery rate of simulated water samples was 98.37-101.15%, which showed that this method was feasible for MOX analysis of actual water samples.
引用
收藏
页码:4226 / 4232
页数:7
相关论文
共 50 条
  • [31] Carbon quantum dots as fluorescence resonance energy transfer sensors for organophosphate pesticides determination
    Wu, Xiaoli
    Song, Yang
    Yan, Xu
    Zhu, Chengzhou
    Ma, Yongqiang
    Du, Dan
    Lin, Yuehe
    BIOSENSORS & BIOELECTRONICS, 2017, 94 : 292 - 297
  • [32] Ratiometric fluorescence sensor arrays based on quantum dots for detection of proteins
    Chang, Ning
    Lu, Yuexiang
    Mao, Jinpeng
    Yang, Jiaoe
    Li, Mengnan
    Zhang, Sichun
    Liu, Yueying
    ANALYST, 2016, 141 (06) : 2046 - 2052
  • [33] A novel fluorescence and resonance Rayleigh scattering probe based on quantum dots for the detection of albendazole
    Li, Qin
    Tan, Xuanping
    Fu, Lingli
    Liu, Qu
    Tang, Weiwei
    ANALYTICAL METHODS, 2015, 7 (02) : 614 - 620
  • [34] Ratiometric Fluorescence Probes Based on Carbon Dots
    Yan, Fanyong
    Bai, Zhangjun
    Liu, Fan
    Zu, Fanlin
    Zhang, Ruiqi
    Xu, Jinxia
    Chen, Li
    CURRENT ORGANIC CHEMISTRY, 2018, 22 (01) : 57 - 66
  • [35] A Fluorescence Resonance Energy Transfer Biosensor Based on Graphene Quantum Dots and Protoporphyrin IX for the Detection of Melamine
    Xue, Gao
    Zhiying, Ma
    Xiuying, Liu
    Lijun, Tang
    Jianrong, Li
    JOURNAL OF FLUORESCENCE, 2020, 30 (06) : 1463 - 1468
  • [36] A Fluorescence Resonance Energy Transfer Biosensor Based on Graphene Quantum Dots and Protoporphyrin IX for the Detection of Melamine
    Gao Xue
    Ma Zhiying
    Liu Xiuying
    Tang Lijun
    Li Jianrong
    Journal of Fluorescence, 2020, 30 : 1463 - 1468
  • [37] Study on fluorescence resonance energy transfer detection of oxaquinic acid based on manganese doped quantum dots
    Peng, Maomin
    Xia, Hong
    Peng, Xitian
    Liu, Li
    Chinese Journal of Analysis Laboratory, 2021, 40 (02) : 198 - 202
  • [38] Ratiometric Fluorescence Immunoassay Based on Carbon Quantum Dots for Sensitive Detection of Malachite Green in Fish
    Yang, Guangxin
    Zhang, Jingru
    Gu, Lin
    Tang, Yunyu
    Zhang, Xuan
    Huang, Xuanyun
    Shen, Xiaosheng
    Zhai, Wenlei
    Fodjo, Essy Kouadio
    Kong, Cong
    BIOSENSORS-BASEL, 2023, 13 (01):
  • [39] Ratiometric fluorescence biosensor based on CdTe quantum and carbon dots for double strand DNA detection
    Liang, Si-Si
    Qi, Liang
    Zhang, Rui-Ling
    Jin, Meng
    Zhang, Zhi-Qi
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 244 : 585 - 590
  • [40] Fluorescence Probe for Detection of Paeoniflorin Using ZnTe Quantum Dots
    Zheng, Bodan
    Li, Baohong
    Chen, Zhi
    Xing, Xiaowei
    Wu, Dudu
    IEEE SENSORS JOURNAL, 2018, 18 (03) : 918 - 924