High-Sensitivity and High-Throughput Quantification of Everolimus in Human Whole Blood Using Ultrahigh-Performance Liquid Chromatography Coupled With Tandem Mass Spectrometry

被引:2
作者
Miyagi, Chika [1 ]
Tanaka, Ryota [1 ]
Hirata, Kenshiro [2 ]
Watanabe, Takuma [1 ]
Tatsuta, Ryosuke [1 ]
Miyamura, Shigeyuki [2 ]
Itoh, Hiroki [1 ]
机构
[1] Oita Univ Hosp, Dept Clin Pharm, 1-1 Idaigaoka, Yufu, Oita 8795593, Japan
[2] Sojo Univ, Fac Pharmaceut Sci, Dept Clin Pharmaceut, Kumamoto, Japan
基金
日本学术振兴会;
关键词
everolimus; therapeutic drug monitoring; ultrahigh-performance liquid chromatography coupled with tandem mass spectrometry; latex agglutination turbidimetric; solid-phase extraction; LC-MS/MS; POLARIZATION IMMUNOASSAY; IMMUNOSUPPRESSIVE DRUGS; HPLC-UV; TACROLIMUS; SIROLIMUS; CYCLOSPORINE; PHARMACOKINETICS; THERAPY;
D O I
10.1097/FTD.0000000000000985
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Rigorous dose adjustment by therapeutic drug monitoring (TDM) is recommended when everolimus (EVR) is administered for immunosuppression. In this study, the authors developed a highly sensitive ultrahigh-performance liquid chromatography coupled with the tandem mass spectrometry (UHPLC-MS/MS) method for measuring EVR concentrations in whole blood using a high-throughput solid-phase extraction method for sample pretreatment. Furthermore, the blood EVR concentrations in routine TDM samples from patients who underwent renal transplantation measured using the established UHPLC-MS/MS method were compared with those measured using the latex agglutination turbidimetric immunoassay (LTIA). Methods: Blood samples were pretreated by solid-phase extraction using a 96-well HLB mu Elution plate. The clinical application of the newly developed method was evaluated using 87 blood samples from 19 patients who underwent kidney transplant. Results: The calibration curve showed good linearity over a wide range of 0.1-50 ng/mL, with relative error <= 15% obtained from the back calculation of calibrators, and <= 20% for the lower limit of quantification. Within-batch and batch-to-batch accuracies and precisions fulfilled the acceptance criteria of the US Food and Drug Administration guidelines for bioanalytical method validation. The extraction recovery rates were good (>= 65.2%), and almost no matrix effects were found in any of the quality control samples. Blood EVR concentrations measured by UHPLC-MS/MS were positively correlated with those measured by LTIA. A Bland-Altman plot indicated that the UHPLC-MS/MS method yielded better measurements than the LTIA method, regardless of the concentration. Conclusions: Therefore, the authors succeeded in developing a novel high-sensitivity and high-throughput method for measuring blood EVR concentration by UHPLC-MS/MS using a mu Elution plate for sample pretreatment.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
[41]   Determination of 16 Mycotoxins in Maize by Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry [J].
Li, Xia ;
Liu, Bin ;
Wang, Fengen ;
Ma, Xinfeng ;
Li, Zengmei ;
Guo, Dongliang ;
Wang, Yutao ;
Wan, Fachun ;
Deng, Ligang ;
Zhang, Shuqiu .
ANALYTICAL LETTERS, 2018, 51 (05) :702-716
[42]   The analysis of azocyclotin and cyhexatin residues in fruits using ultrahigh-performance liquid chromatography-tandem mass spectrometry [J].
Ma, You-Ning ;
Gui, Wen-Jun ;
Zhu, Guo-Nian .
ANALYTICAL METHODS, 2015, 7 (05) :2108-2113
[43]   Propafenone quantification in human plasma by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry in a bioequivalence study [J].
Severino, Beatrice ;
Luisi, Giancarlo ;
Iwamoto, Renan Donomae ;
Moreno, Ronilson Agnaldo ;
Teixeira, Victor Perez ;
Di Vaio, Paola ;
Saccone, Irene ;
Magli, Elisa ;
Santagada, Vincenzo ;
Caliendo, Giuseppe ;
Mendes, Gustavo D. ;
De Nucci, Gilberto .
INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2018, 56 (06) :280-291
[44]   Volumetric absorptive microsampling for the quantification of tacrolimus in capillary blood by high performance liquid chromatography-tandem mass spectrometry [J].
Tron, Camille ;
Ferrand-Sorre, Marie-Jose ;
Querzerho-Raguideau, Julie ;
Chemouny, Jonathan M. ;
Houssel-Debry, Pauline ;
Verdier, Marie-Clemence ;
Bellissant, Eric ;
Lemaitre, Florian .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1165
[45]   Analysis of cyclosporin A, tacrolimus, sirolimus, and everolimus in dried blood spot samples using liquid chromatography tandem mass spectrometry [J].
den Burger, J. C. G. ;
Wilhelm, A. J. ;
Chahbouni, A. ;
Vos, R. M. ;
Sinjewel, A. ;
Swart, E. L. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (6-7) :1803-1811
[46]   Quantification of human pharmaceuticals in water samples by high performance liquid chromatography-tandem mass spectrometry [J].
Nebot, Carolina ;
Gibb, Stuart W. ;
Boyd, Kenneth G. .
ANALYTICA CHIMICA ACTA, 2007, 598 (01) :87-94
[47]   Determination of Immunosuppressive Pharmaceuticals in Whole Blood Following Kidney Transplantation by High-performance Liquid Chromatography-Tandem Mass Spectrometry [J].
Mislanova, Csilla ;
Pribojova, Jana ;
Valachovicova, Martina ;
Zilinska, Zuzana .
ANALYTICAL LETTERS, 2017, 50 (15) :2359-2368
[48]   Simultaneous Quantification of Pantoprazole and Levosulpiride in Spiked Human Plasma Using High Performance Liquid Chromatography Tandem Mass Spectrometry [J].
Srinandan, Vulli ;
Nagappan, Krishnaveni ;
Pate, Sonam ;
Yamjala, Karthik ;
Byran, Gowramma ;
Babu, Basavan .
CURRENT PHARMACEUTICAL ANALYSIS, 2019, 15 (01) :17-23
[49]   Simultaneous quantification of idelalisib, fludarabine and lenalidomide in rat plasma by using high-performance liquid chromatography coupled with heated electrospray ionization tandem mass spectrometry [J].
Veeraraghavan, Sridhar ;
Thappali, Satheeshmanikandan ;
Viswanadha, Srikant ;
Nalla, Santhoshkumar ;
Chennupati, Sandhyarani ;
Golla, Manikantakumar ;
Vakkalanka, Swaroopkumar ;
Rangasamy, Manivannan .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 949 :63-69
[50]   A sensitive assay for the quantification of morphine and its active metabolites in human plasma and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry [J].
Clavijo, Claudia F. ;
Hoffman, Keith L. ;
Thomas, James J. ;
Carvalho, Brendan ;
Chu, Larry F. ;
Drover, David R. ;
Hammer, Gregory B. ;
Christians, Uwe ;
Galinkin, Jeffrey L. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (03) :715-728