Patch testing with budesonide in serial dilutions: the significance of dose, occlusion time and reading time

被引:53
作者
Isaksson, M
Bruze, M
Goossens, A
Lepoittevin, JP
机构
[1] Lund Univ, Dept Occupat & Environm Dermatol, Malmo, Sweden
[2] Katholieke Univ Leuven, Dept Dermatol, Louvain, Belgium
[3] Univ Strasbourg 1, Lab Dermatochem, Strasbourg, France
关键词
corticosteroids; budesonide; dose-response relationship; edge effect; patch testing technique; contact sensitivity; serial dilutions; allergic contact dermatitis; false-negative reactions;
D O I
10.1111/j.1600-0536.1999.tb05972.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Budesonide is advocated as a marker molecule for corticosteroid contact allergy. When patch testing corticosteroids, one must consider their sensitizing potential but also their anti-inflammatory properties, as well as the possibility of different time courses for such properties. The dose-response relationship for budesonide was therefore investigated with regard to dose, oo elusion time, and reading time. 10 patients were patch tested with budesonide in ethanol in serial dilutions from 2.0% down to 0.0002% with occlusion times of 48, 24, and 5 h. Readings were on D2, D4, and D7. The 48-h occlusion picked up most positive reactors, 8/10. The D4 reading (48-h occlusion) detected most positive reactors, 8/10, and here 0.002% picked up most contact allergies. Late readings favoured high concentrations. The "edge effect" was noted for several concentrations at early readings. Due to the individual corticosteroid reactivity, the dose-response relationship and the time courses of the elicitation and the anti-inflammatory capacity, several features may be explained, i.e., that lower concentrations may detect budesonide allergy better at early readings, that patients with an "edge reaction" can have positive reactions to lower concentrations.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 18 条
  • [1] CONTACT HYPERSENSITIVITY TO TOPICAL CORTICOSTEROIDS
    BURDEN, AD
    BECK, MH
    [J]. BRITISH JOURNAL OF DERMATOLOGY, 1992, 127 (05) : 497 - 500
  • [2] THE NEW CORTICOSTEROIDS - ARE THEY EFFECTIVE AND SAFE
    DEGREEF, H
    DOOMSGOOSSENS, A
    [J]. DERMATOLOGIC CLINICS, 1993, 11 (01) : 155 - 160
  • [3] CLINICAL ASPECTS OF CONTACT ALLERGY TO CORTICOSTEROIDS
    DOOMSGOOSSENS, A
    DEGREEF, H
    [J]. DERMATOLOGY, 1994, 189 : 54 - 55
  • [4] CONTACT ALLERGY TO HYDROCORTISONE AND THIXOCORTOL PIVALATE - PROBLEMS IN THE DETECTION OF CORTICOSTEROID SENSITIVITY
    DOOMSGOOSSENS, A
    VERSCHAEVE, H
    DEGREEF, H
    VANBERENDONCKS, J
    [J]. CONTACT DERMATITIS, 1986, 14 (02) : 94 - 102
  • [5] RESULTS OF ROUTINE PATCH TESTING WITH CORTICOSTEROID SERIES IN 2073 PATIENTS
    DOOMSGOOSSENS, A
    MORREN, M
    [J]. CONTACT DERMATITIS, 1992, 26 (03) : 182 - 191
  • [6] PATCH TESTING WITH CORTICOSTEROIDS IN XEROGEL FORMULATIONS
    DOOMSGOOSSENS, A
    PAUWELS, M
    BOURDA, A
    DEGREEF, H
    KINGET, R
    [J]. CONTACT DERMATITIS, 1992, 26 (03) : 206 - 207
  • [7] A SURVEY OF THE RESULTS OF PATCH TESTS WITH TIXOCORTOL PIVALATE
    DOOMSGOOSSENS, A
    ANDERSEN, KE
    BURROWS, D
    CAMARASA, JG
    DUCOMBS, G
    FROSCH, PJ
    LACHAPELLE, JM
    LAHTI, A
    MENNE, T
    RYCROFT, RJG
    WHITE, IR
    WILKINSON, JD
    [J]. CONTACT DERMATITIS, 1989, 20 (02) : 158 - 158
  • [8] DOOMSGOOSSENS A, 1991, EXOGENOUS DERMATOSES, P299
  • [9] Fregert S, 1981, MANUAL CONTACT DERMA
  • [10] THE EDGE EFFECT WITH PATCH TEST MATERIALS
    FYAD, A
    MASMOUDI, ML
    LACHAPELLE, JM
    [J]. CONTACT DERMATITIS, 1987, 16 (03) : 147 - 151