Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS

被引:18
作者
Godshaw, Joshua [1 ,2 ]
Hopfer, Helene [3 ]
Nelson, Jenny [1 ,2 ,4 ]
Ebeler, Susan E. [1 ,2 ]
机构
[1] Univ Calif Davis, Dept Viticulture & Enol, One Shields Ave, Davis, CA 95616 USA
[2] Univ Calif Davis, Food Safety & Measurement Facil, One Shields Ave, Davis, CA 95616 USA
[3] Penn State Univ, Dept Food Sci, 202 Food Sci Bldg, University Pk, PA 16802 USA
[4] Agilent Technol, 5301 Stevens Creek Blvd, Santa Clara, CA 95051 USA
关键词
ICP-MS; sample preparation; wine analysis; isotope dilution; elemental profiling; PLASMA-MASS-SPECTROMETRY; RED WINES; ISOTOPE-DILUTION; WHITE WINES; ORIGIN; LEAD; METALS; RATIOS;
D O I
10.3390/molecules22101609
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the Cu-63:Cu-65 instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.
引用
收藏
页数:15
相关论文
共 50 条
[31]   Method Study on Calcium and Phosphorus Simultaneous Determination by Microwave-Digestion and ICP-MS [J].
Chen Guo-you ;
Ma Yong-hua ;
Du Ying-qiu ;
Shan Hong ;
Jin Hai-tao ;
Su Ping .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (08) :2274-2276
[32]   Determination of Zn, Cu and Fe in human patients' serum using micro sampling ICP-MS and sample dilution [J].
Abduljabbar, Tharwat N. ;
Sharp, Barry L. ;
Reid, Helen J. ;
Barzegar-Befroeid, Neda ;
Peto, Tunde ;
Lengyel, Imre .
TALANTA, 2019, 204 :663-669
[33]   Comparison of digestion methods for ICP-MS determination of trace elements in fish tissues [J].
Ashoka, Shailini ;
Peake, Barrie M. ;
Bremner, Graeme ;
Hageman, Kimberly J. ;
Reid, Malcolm R. .
ANALYTICA CHIMICA ACTA, 2009, 653 (02) :191-199
[34]   The role of different soil sample digestion methods on trace elements analysis: a comparison of ICP-MS and INAA measurement results [J].
Stefania Gaudino ;
Chiara Galas ;
Maria Belli ;
Sabrina Barbizzi ;
Paolo de Zorzi ;
Radojko Jaćimović ;
Zvonka Jeran ;
Alessandra Pati ;
Umberto Sansone .
Accreditation and Quality Assurance, 2007, 12 :84-93
[35]   Determination of Pt from coke samples by ICP-MS after microwave assisted digestion and microwave assisted cloud point extraction [J].
Niemela, Matti ;
Huttunen, Satu M. ;
Gornostayev, Stanislav S. ;
Peramaki, Paavo .
MICROCHIMICA ACTA, 2009, 166 (3-4) :255-260
[36]   The role of different soil sample digestion methods on trace elements analysis: a comparison of ICP-MS and INAA measurement results [J].
Gaudino, Stefania ;
Galas, Chiara ;
Belli, Maria ;
Barbizzi, Sabrina ;
de Zorzi, Paolo ;
Jacimovic, Radojko ;
Jeran, Zvonka ;
Pati, Alessandra ;
Sansone, Umberto .
ACCREDITATION AND QUALITY ASSURANCE, 2007, 12 (02) :84-93
[37]   Comparison of DMA-80 and ICP-MS Combined with Closed-Vessel Microwave Digestion for the Determination of Mercury in Coal [J].
Zhang, Siyu ;
Zhou, Mingxuan .
JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2020, 2020
[38]   Application of MARS-5 and UltraWAVE Microwave Systems to the Digestion of Silicate Rocks Followed by ICP-MS Analysis [J].
Nikolaeva, I. V. ;
Palesskiy, S. V. .
INORGANIC MATERIALS, 2024, 60 (01) :18-27
[39]   The impact of sample preparation on the elemental composition of soft tissues assessed by laser ablation ICP-MS [J].
Jagielska, Agata ;
Ruszczynska, Anna ;
Bulska, Ewa ;
Wagner, Barbara .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (07) :1340-1350
[40]   Toxic metal levels in cocoa powder and chocolate by ICP-MS method after microwave-assisted digestion [J].
Lo Dico, Gianluigi Maria ;
Galvano, Fabio ;
Dugo, Giacomo ;
D'ascenzi, Carlo ;
Macaluso, Andrea ;
Vella, Antonio ;
Giangrosso, Giuseppe ;
Cammilleri, Gaetano ;
Ferrantelli, Vincenzo .
FOOD CHEMISTRY, 2018, 245 :1163-1168