Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS

被引:18
作者
Godshaw, Joshua [1 ,2 ]
Hopfer, Helene [3 ]
Nelson, Jenny [1 ,2 ,4 ]
Ebeler, Susan E. [1 ,2 ]
机构
[1] Univ Calif Davis, Dept Viticulture & Enol, One Shields Ave, Davis, CA 95616 USA
[2] Univ Calif Davis, Food Safety & Measurement Facil, One Shields Ave, Davis, CA 95616 USA
[3] Penn State Univ, Dept Food Sci, 202 Food Sci Bldg, University Pk, PA 16802 USA
[4] Agilent Technol, 5301 Stevens Creek Blvd, Santa Clara, CA 95051 USA
关键词
ICP-MS; sample preparation; wine analysis; isotope dilution; elemental profiling; PLASMA-MASS-SPECTROMETRY; RED WINES; ISOTOPE-DILUTION; WHITE WINES; ORIGIN; LEAD; METALS; RATIOS;
D O I
10.3390/molecules22101609
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the Cu-63:Cu-65 instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.
引用
收藏
页数:15
相关论文
共 50 条
[21]   Determination of Trace Elements in Waste Beer Yeasts by ICP-MS with Microwave Digestion [J].
Cheng Xian-zhong ;
Jin Can ;
Zhang Kai-cheng .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (10) :2421-2424
[22]   Investigation of Trace Element Content in the Seeds, Pulp, and Peel of Mashui Oranges Using Microwave Digestion and ICP-MS Analysis [J].
Chen, Lingyun ;
Shen, Mei ;
Ma, Ande ;
Han, Weili .
BIOLOGICAL TRACE ELEMENT RESEARCH, 2018, 182 (01) :152-158
[23]   Chemometric classification and discrimination of herbal dietary supplements based on ICP-MS elemental profiling [J].
Benutic, Anica ;
Marcius, Bernardo ;
Nemet, Ivan ;
Roncevic, Sanda .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2022, 114
[24]   Elemental profiling by ICP-MS as a tool for geographical discrimination: The case of bracatinga honeydew honey [J].
Silva, Bibiana ;
Gonzaga, Luciano Valdomiro ;
Maltez, Heloisa Franca ;
Samochvalov, Katia Bennett ;
Fett, Roseane ;
Oliveira Costa, Ana Carolina .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2021, 96
[25]   Study on Microwave Digestion of Coal for the Determination of Multi-Element by ICP-OES and ICP-MS [J].
Wang Hui ;
Song Qiang ;
Yao Qiang ;
Chen Chang-he ;
Yu Fei-lu .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (06) :1662-1665
[26]   Determination of toxic elements in coal by ICP-MS after digestion using microwave-induced combustion [J].
Antes, Fabiane G. ;
Duarte, Fabio A. ;
Mesko, Marcia F. ;
Nunes, Matheus A. G. ;
Pereira, Vanda A. ;
Mueller, Edson I. ;
Dressler, Valderi L. ;
Flores, Erico M. M. .
TALANTA, 2010, 83 (02) :364-369
[27]   Microwave Digestion and ICP-MS Determination of Major and Trace Elements in Waste Sm-Co Magnets [J].
Korotkova, Natalia A. ;
Baranovskaya, Vasilisa B. ;
Petrova, Kseniya, V .
METALS, 2022, 12 (08)
[28]   Comparison of microwave-assisted digestion methods and selection of internal standards for the determination of Rh, Pd and Pt in dust samples by ICP-MS [J].
Niemelä, M ;
Kola, H ;
Perämäki, P ;
Piispanen, J ;
Poikolainen, J .
MICROCHIMICA ACTA, 2005, 150 (3-4) :211-217
[29]   Ultraviolet radiation combined with microwave-assisted wet digestion of Antarctic seaweeds for further determination of toxic elements by ICP-MS [J].
Mesko, Marcia F. ;
Picoloto, Rochele S. ;
Ferreira, Lizangela R. ;
Costa, Vanize C. ;
Pereira, Claudio M. P. ;
Colepicolo, Pio ;
Muller, Edson I. ;
Flores, Erico M. M. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (01) :260-266
[30]   Bromine, Chlorine, and Iodine Determination in Soybean and its Products by ICP-MS After Digestion Using Microwave-Induced Combustion [J].
Pereira Barbosa, Jose Tiago ;
Moreira Santos, Clarissa Marques ;
Bispo, Lilia dos Santos ;
Lyra, Fernanda Henrique ;
David, Jorge Mauricio ;
Andrade Korn, Maria das Gracas ;
Moraes Flores, Erico Marlon .
FOOD ANALYTICAL METHODS, 2013, 6 (04) :1065-1070