Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS

被引:17
作者
Godshaw, Joshua [1 ,2 ]
Hopfer, Helene [3 ]
Nelson, Jenny [1 ,2 ,4 ]
Ebeler, Susan E. [1 ,2 ]
机构
[1] Univ Calif Davis, Dept Viticulture & Enol, One Shields Ave, Davis, CA 95616 USA
[2] Univ Calif Davis, Food Safety & Measurement Facil, One Shields Ave, Davis, CA 95616 USA
[3] Penn State Univ, Dept Food Sci, 202 Food Sci Bldg, University Pk, PA 16802 USA
[4] Agilent Technol, 5301 Stevens Creek Blvd, Santa Clara, CA 95051 USA
关键词
ICP-MS; sample preparation; wine analysis; isotope dilution; elemental profiling; PLASMA-MASS-SPECTROMETRY; RED WINES; ISOTOPE-DILUTION; WHITE WINES; ORIGIN; LEAD; METALS; RATIOS;
D O I
10.3390/molecules22101609
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the Cu-63:Cu-65 instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] COMPARISON OF SAMPLE PREPARATION TECHNIQUES FOR MULTIELEMENTAL ANALYSIS OF WINE SAMPLES BY ICP-MS
    Katona, R.
    Abranko, L.
    Stefanka, Zs.
    ACTA ALIMENTARIA, 2012, 41 : 83 - 91
  • [2] Intraregional classification of wine via ICP-MS elemental fingerprinting
    Coetzee, P. P.
    van Jaarsveld, F. P.
    Vanhaecke, F.
    FOOD CHEMISTRY, 2014, 164 : 485 - 492
  • [3] Microwave-assisted Digestion of Environmental Soil Sample and Measurement of Plutonium by ICP-MS
    Xu H.
    Ma T.
    Li D.
    Zhan J.
    Wang Y.
    Wang B.
    Wang Y.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (04): : 603 - 610
  • [4] ICP-MS measurement of toxic and essential elements in human breast milk. A comparison of alkali dilution and acid digestion sample preparation methods
    Levi, Michael
    Hjelm, Camilla
    Harari, Florencia
    Vahter, Marie
    CLINICAL BIOCHEMISTRY, 2018, 53 : 81 - 87
  • [5] Microwave-Assisted Digestion Using Diluted Nitric Acid for Multi-element Determination in Rice by ICP OES and ICP-MS
    Tarantino, Taiana B.
    Barbosa, Isa S.
    Lima, Daniel de C.
    Pereira, Madson de G.
    Teixeira, Leonardo S. G.
    Korn, Maria Gracas A.
    FOOD ANALYTICAL METHODS, 2017, 10 (04) : 1007 - 1015
  • [6] Determination of platinum and rhodium in dust and plant samples using microwave-assisted sample digestion and ICP-MS
    Niemelä, M
    Perämäki, P
    Piispanen, J
    Poikolainen, J
    ANALYTICA CHIMICA ACTA, 2004, 521 (02) : 137 - 142
  • [7] Determination of Bromine in Plastics by ICP-MS Using Microwave Digestion
    Matsumoto, Akihiro
    Osaki, Shusuke
    Kobata, Toshitsugu
    Tanigughi, Hisaji
    BUNSEKI KAGAKU, 2014, 63 (02) : 147 - 150
  • [8] Determination of Elemental Impurities in Acyclovir Ointment and Raw Materials Using Microwave Acid Digestion (MW-AD) and ICP-MS
    Gonzalez, Mario H.
    da Silva, Caroline S.
    Amaral, Clarice D. B.
    Bianchi, Silmara R.
    de Oliveira, Luciano H. B.
    Coelho, Jessica S.
    Oliveira, Andrea
    Nogueira, Ana Rita A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (01) : 98 - 105
  • [9] Alkali dilution of blood samples for high throughput ICP-MS analysis-comparison with acid digestion
    Lu, Ying
    Kippler, Maria
    Harari, Florencia
    Grander, Margaretha
    Palm, Brita
    Nordqvist, Helena
    Vahter, Marie
    CLINICAL BIOCHEMISTRY, 2015, 48 (03) : 140 - 147
  • [10] Determination of 9 Heavy Metal Elements in Sediment by ICP-MS Using Microwave Digestion for Sample Preparation
    Liang Shu-xuan
    Wang Xin
    Wu Hong
    Sun Han-wen
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (03) : 809 - 812