Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bone-patellar tendon-bone grafts

被引:36
作者
Zantop, T
Ruemmler, M
Welbers, B
Langer, M
Weirnann, A
Petersen, W
机构
[1] Univ Hosp Muenster, Dept Trauma Hand & Reconstruct Surg, D-48149 Munster, Germany
[2] Univ Kiel, Dept Orthopaed Surg, D-24098 Kiel, Germany
关键词
anterior cruciate ligament; bone-patellar tendon-bone graft fixation; biomechanics; maximal load; cyclic loading;
D O I
10.1016/j.arthro.2005.05.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The aim of this study was to compare ultimate load, yield load, stiffness, and displacement after cyclic loading of a cross-pin technique and an interference screw technique for the fixation of bone-patellar tendon-bone (BPTB) grafts in anterior cruciate ligament (ACL) reconstruction. Type of Study: Biomechanical in vitro study. Methods: The devices tested were 2 2.7-mm biodegradable pins (RigidFix; Ethicon, Mitek Division, Norderstedt, Germany) and biodegradable interference screws (Absolute; Innovasive Devices, Marlborough, MA). Each device was used for the fixation of 10 8-mm, 9-mm, or 10-mm sized human BPTB grafts in tunnels drilled in bovine knees. Ultimate load, yield load, stiffness, and displacement after cyclic loading (1,000 cycles between 50 and 250 N) were then evaluated. Results: All 8-mm grafts that were fixed with cross-pins failed after a mean of 124 cycles of load. The 9-mm and 10-mm grafts survived the cyclic loading protocol. Yield load and maximum load of the 10-mm groups (cross-pin and interference screw) were significantly higher than that of the 9-mm groups. There was no significant difference in maximum load, yield load, and stiffness between the cross-pin and interference screw fixation technique for I graft size. Conclusions: The biomechanical data suggest that femoral fixation of 9-mm and 10-mm BPTB grafts using 2.7-mm biodegradable cross-pins leads to primary stability that is comparable to that of biodegradable interference screws. Fixation of 8-mm BPTB grafts using 2.7-mm biodegradable cross-pins had poor results. Clinical Relevance: The diameter of the bone block is the limiting factor for the final fixation strength and the cyclical survival when using cross-pins. We strongly recommend not using this technique for bone blocks smaller than 9-mm in diameter.
引用
收藏
页码:934 / 941
页数:8
相关论文
共 31 条
[1]   Initial fixation strength of polylactic acid interference screws in anterior cruciate ligament reconstruction [J].
Abate, JA ;
Fadale, PD ;
Hulstyn, MJ ;
Walsh, WR .
ARTHROSCOPY, 1998, 14 (03) :278-284
[2]  
[Anonymous], 1998, KNEE SURG SPORTS S1, DOI DOI 10.1007/s001670050226
[3]   Graft fixation in cruciate ligament reconstruction [J].
Brand, J ;
Weiler, A ;
Caborn, DNM ;
Brown, CH ;
Johnson, DL .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (05) :761-774
[4]  
Brown G A, 1996, Knee Surg Sports Traumatol Arthrosc, V3, P238, DOI 10.1007/BF01466626
[5]  
CABORN DNM, 1997, ARTHROSCOPY, V10, P524
[6]   ANTERIOR AND POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION IN RHESUS-MONKEYS - A HISTOLOGICAL, MICRO-ANGIOGRAPHIC, AND BIOMECHANICAL ANALYSIS [J].
CLANCY, WG ;
NARECHANIA, RG ;
ROSENBERG, TD ;
GMEINER, JG ;
WISNEFSKE, DD ;
LANGE, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (08) :1270-1284
[7]  
Corsetti JR, 1996, CLIN ORTHOP RELAT R, P42
[8]   Current concepts review - The science of reconstruction of the anterior cruciate ligament [J].
Frank, CB ;
Jackson, DW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (10) :1556-1576
[9]   Current trends in anterior cruciate ligament reconstruction Part II. Operative procedures and clinical correlations [J].
Fu, FH ;
Bennett, CH ;
Ma, CB ;
Menetrey, J ;
Lattermann, C .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (01) :124-130
[10]  
GIBSON L, 1987, CELLULAR SOLIDS, P316