Catheter Ablation of Atrial Fibrillation Using Zero-Fluoroscopy Technique: A Randomized Trial

被引:95
作者
Bulava, Alan [1 ,2 ]
Hanis, Jiri [1 ]
Eisenberger, Martin [1 ,2 ]
机构
[1] Budweis Hosp, Dept Cardiol, Budweis 37001, Czech Republic
[2] Univ South Bohemia, Fac Hlth & Social Studies, Budweis, Czech Republic
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2015年 / 38卷 / 07期
关键词
atrial fibrillation; radiation; zero fluoroscopy; pulmonary vein isolation; contact force; catheter ablation; OCCUPATIONAL-HEALTH-HAZARDS; INTERVENTIONAL LABORATORY TIME; PULMONARY VEIN ISOLATION; RADIATION-EXPOSURE; SAFER ENVIRONMENT; TACHYCARDIA; MANAGEMENT; RISK;
D O I
10.1111/pace.12634
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundRecent advances in 3D mapping systems, such as simultaneous visualization of multiple catheters and contact force measurement, have allowed a significant reduction in fluoroscopic times during radiofrequency (RF) ablation (RFA) procedures. The objective was to investigate whether RFA of paroxysmal atrial fibrillation (PAF) using the CARTO 3 system (Biosense Webster, Diamond Bar, CA, USA) and intracardiac echocardiography (ICE) can be performed safely without fluoroscopy. Methods and ResultsEighty patients with PAF were randomized in a 1:1 ratio to undergo either fluoroscopically guided pulmonary vein isolation (PVI) (X+) or PVI without fluoroscopy (X-). In the X- fluoroscopy group, catheter placement, transseptal puncture, left atrial geometry reconstruction, and PVI were accomplished solely using ICE imaging and CARTO mapping. The total procedure duration and RF application time in both the X- and X+ groups were comparable (92.5 22.9 minutes vs 99.9 +/- 15.9 minutes, P = 0.11 and 1785 +/- 548 seconds vs 1755 +/- 450 seconds, P = 0.79, respectively). Zero fluoroscopic time was achieved in all patients in the X- group with the exception of one patient, where 8 seconds of fluoroscopy was needed to assess proper position of the guide-wire in the femoral vein. No serious procedure-related complications were recorded and no differences in arrhythmia-free survival at 12 months were found between the groups. ConclusionRFA using ICE imaging and the CARTO 3 mapping system with contact force measurement is capable of eliminating fluoroscopy in patients undergoing PVI. Exclusion of fluoroscopic imaging does not seem to compromise patient safety and does not affect overall procedure duration, RF application time, or mid-term efficacy.
引用
收藏
页码:797 / 806
页数:10
相关论文
共 50 条
  • [31] Zero-fluoroscopy approach for ablation of supraventricular tachycardia using the Ensite NavX system: a multicenter experience
    Chen, Guangzhi
    Wang, Yan
    Proietti, Riccardo
    Wang, Xunzhang
    Ouyang, Feifan
    Ma, Chang Sheng
    Yu, Rong Hui
    Zhao, Chunxia
    Ma, Kezhong
    Qiu, Jie
    Liu, Qigong
    Wang, Dao Wen
    BMC CARDIOVASCULAR DISORDERS, 2020, 20 (01)
  • [32] Randomized Controlled Trial of Surgical Versus Catheter Ablation for Paroxysmal and Early Persistent Atrial Fibrillation
    Adiyaman, Ahmet
    Buist, Thomas J.
    Beukema, Rypko J.
    Smit, Jaap Jan J.
    Delnoy, Peter Paul H. M.
    Hemels, Martin E. W.
    Sie, Hauw T.
    Misier, Anand R. Ramdat
    Elvan, Arif
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (10) : e006182
  • [33] Maximum voltage gradient technique for optimization of ablation for typical atrial flutter with zero-fluoroscopy approach
    Deutsch, Karol
    Sledz, Janusz
    Mazij, Mariusz
    Ludwik, Bartosz
    Labus, Michal
    Karbarz, Dariusz
    Pasicka, Bernadetta
    Chrabaszcz, Michal
    Sledz, Arkadiusz
    Klank-Szafran, Monika
    Vitali-Sendoz, Laura
    Kameczura, Tomasz
    Spikowski, Jerzy
    Stec, Piotr
    Ujda, Marek
    Stec, Sebastian
    MEDICINE, 2017, 96 (25)
  • [34] Contemporary Challenges of Catheter Ablation for Atrial Fibrillation
    Weerasooriya, Rukshen
    Shah, Ashok J.
    Hocini, Meleze
    Jais, Pierre
    Haissaguerre, Michel
    CLINICAL THERAPEUTICS, 2014, 36 (09) : 1145 - 1150
  • [35] Contact force control - the key to safe zero-fluoroscopy catheter ablation of atrioventricular nodal reentrant tachycardia
    Kerst, G.
    Weig, H-J.
    Weretka, S.
    Seizer, P.
    Hofbeck, M.
    Gawaz, M.
    Schreieck, J.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2011, 136 (39) : 1946 - 1951
  • [36] Catheter Ablation of Atrial Fibrillation - State of the Art
    Kumagai, Koichiro
    CIRCULATION JOURNAL, 2011, 75 (10) : 2305 - 2311
  • [37] Catheter ablation for atrial fibrillation in a low-volume center using contemporary technology
    Tay, Julian Cheong Kiat
    Cai, Xinzhe James
    Lin, Jing
    Liang, Shufen
    Him, Ai Ling
    Hamid, Sherida Binte Syed
    Wong, Kelvin Cheok Keng
    Yeo, Colin
    Tan, Vern Hsen
    IJC HEART & VASCULATURE, 2020, 31
  • [38] Zero-fluoroscopy ablation in patients with cardiac electronic implantable devices
    Shimamoto, Keiko
    Yamagata, Kenichiro
    Wakamiya, Akinori
    Ueda, Nobuhiko
    Kamakura, Tsukasa
    Wada, Mitsuru
    Inoue-Yamada, Yuko
    Miyamoto, Koji
    Nagase, Satoshi
    Kusano, Kengo F.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (03) : 423 - 429
  • [39] Zero-fluoroscopy ablation with multielectrode pulse field ablation system: Case series
    Rauber, Martin
    Manninger, Martin
    Eberl, Anna-Sophie
    Scherr, Daniel
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (01): : 117 - 120
  • [40] The Impact of Catheter Ablation in the Interpulmonary Isthmus on Atrial Fibrillation Ablation Outcomes: A Randomized Study
    Letsas, Konstantinos P.
    Efremidis, Michael
    Vlachos, Konstantinos
    Karlis, Dimitrios
    Lioni, Louiza
    Asvestas, Dimitrios
    Valkanas, Kosmas
    Mihas, Constantinos C.
    Sideris, Antonios
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (07) : 709 - 713