Catheter Ablation of Atrial Fibrillation Using Zero-Fluoroscopy Technique: A Randomized Trial

被引:95
作者
Bulava, Alan [1 ,2 ]
Hanis, Jiri [1 ]
Eisenberger, Martin [1 ,2 ]
机构
[1] Budweis Hosp, Dept Cardiol, Budweis 37001, Czech Republic
[2] Univ South Bohemia, Fac Hlth & Social Studies, Budweis, Czech Republic
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2015年 / 38卷 / 07期
关键词
atrial fibrillation; radiation; zero fluoroscopy; pulmonary vein isolation; contact force; catheter ablation; OCCUPATIONAL-HEALTH-HAZARDS; INTERVENTIONAL LABORATORY TIME; PULMONARY VEIN ISOLATION; RADIATION-EXPOSURE; SAFER ENVIRONMENT; TACHYCARDIA; MANAGEMENT; RISK;
D O I
10.1111/pace.12634
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundRecent advances in 3D mapping systems, such as simultaneous visualization of multiple catheters and contact force measurement, have allowed a significant reduction in fluoroscopic times during radiofrequency (RF) ablation (RFA) procedures. The objective was to investigate whether RFA of paroxysmal atrial fibrillation (PAF) using the CARTO 3 system (Biosense Webster, Diamond Bar, CA, USA) and intracardiac echocardiography (ICE) can be performed safely without fluoroscopy. Methods and ResultsEighty patients with PAF were randomized in a 1:1 ratio to undergo either fluoroscopically guided pulmonary vein isolation (PVI) (X+) or PVI without fluoroscopy (X-). In the X- fluoroscopy group, catheter placement, transseptal puncture, left atrial geometry reconstruction, and PVI were accomplished solely using ICE imaging and CARTO mapping. The total procedure duration and RF application time in both the X- and X+ groups were comparable (92.5 22.9 minutes vs 99.9 +/- 15.9 minutes, P = 0.11 and 1785 +/- 548 seconds vs 1755 +/- 450 seconds, P = 0.79, respectively). Zero fluoroscopic time was achieved in all patients in the X- group with the exception of one patient, where 8 seconds of fluoroscopy was needed to assess proper position of the guide-wire in the femoral vein. No serious procedure-related complications were recorded and no differences in arrhythmia-free survival at 12 months were found between the groups. ConclusionRFA using ICE imaging and the CARTO 3 mapping system with contact force measurement is capable of eliminating fluoroscopy in patients undergoing PVI. Exclusion of fluoroscopic imaging does not seem to compromise patient safety and does not affect overall procedure duration, RF application time, or mid-term efficacy.
引用
收藏
页码:797 / 806
页数:10
相关论文
共 50 条
  • [21] Recurrence of Atrial Fibrillation After Catheter Ablation or Antiarrhythmic Drug Therapy in the CABANA Trial
    Poole, Jeanne E.
    Bahnson, Tristram D.
    Monahan, Kristi H.
    Johnson, George
    Rostami, Hoss
    Silverstein, Adam P.
    Al-Khalidi, Hussein R.
    Rosenberg, Yves
    Mark, Daniel B.
    Lee, Kerry L.
    Packer, Douglas L.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (25) : 3105 - 3118
  • [22] Catheter ablation of atrial fibrillation: an update
    Haegeli, Laurent M.
    Calkins, Hugh
    EUROPEAN HEART JOURNAL, 2014, 35 (36) : 2454 - +
  • [23] Catheter Ablation of Atrial Fibrillation Without Fluoroscopy Using Intracardiac Echocardiography and Electroanatomic Mapping
    Ferguson, John D.
    Helms, Adam
    Mangrum, J. Michael
    Mahapatra, Srijoy
    Mason, Pamela
    Bilchick, Ken
    McDaniel, George
    Wiggins, David
    DiMarco, John P.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (06) : 611 - U28
  • [24] Persistent Atrial Fibrillation Ablation using the Tip-Versatile Ablation Catheter
    Davies, Edward J.
    Clayton, Ben
    Lines, Ian
    Haywood, Guy A.
    HEART LUNG AND CIRCULATION, 2016, 25 (07) : 645 - 651
  • [25] Catheter Ablation of Atrial Fibrillation
    Tung, Roderick
    Buch, Eric
    Shivkumar, Kalyanam
    CIRCULATION, 2012, 126 (02) : 223 - 229
  • [26] Catheter ablation of atrial fibrillation
    Lo, Li-Wei
    Chen, Shih-Ann
    CHINESE MEDICAL JOURNAL, 2013, 126 (14) : 2753 - 2761
  • [27] Outcome and safety of intracardiac echocardiography guided left atrial appendage closure within zero-fluoroscopy atrial fibrillation ablation procedures
    Chen, Yi-He
    Wang, Liang-Guo
    Zhou, Xiao-Dong
    Fang, Ying
    Su, Lan
    Wu, Sheng-Jie
    Huang, Wei-Jian
    Xiao, Fang-Yi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (04) : 667 - 676
  • [28] Catheter Ablation of Atrial Fibrillation
    Callahan, Thomas D.
    Di Biase, Luigi
    Horton, Rodney
    Sanchez, Javier
    Gallinghouse, Joseph G.
    Natale, Andrea
    CARDIOLOGY CLINICS, 2009, 27 (01) : 163 - +
  • [29] Optimalendpoint for catheter ablation of longstanding persistent atrial fibrillation: A randomized clinical trial
    Wang, Yuan-long
    Liu, Xu
    Zhang, Yu
    Jiang, Wei-feng
    Zhou, Li
    Qin, Mu
    Zhang, Dao-liang
    Zhang, Xiao-dong
    Wu, Shao-hui
    Xu, Kai
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (02): : 172 - 178
  • [30] Conventional fluoroscopy-guided versus zero-fluoroscopy catheter ablation of supraventricular tachycardias
    Tine Prolič Kalinšek
    Jernej Šorli
    Matevž Jan
    Matjaž Šinkovec
    Bor Antolič
    Luka Klemen
    David Žižek
    Andrej Pernat
    BMC Cardiovascular Disorders, 22