Enhanced flow cytometric method for counting very low numbers of white cells in platelet products

被引:0
作者
Dumont, LJ
Dumont, DF
机构
来源
CYTOMETRY | 1996年 / 26卷 / 04期
关键词
leukocyte reduction; quality control; leukocyte counting; rare event analysis; platelets;
D O I
10.1002/(SICI)1097-0320(19961215)26:4<311::AID-CYTO12>3.3.CO;2-D
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: The increased demand far leukocyte-reduced platelet products has prompted actions both by blood suppliers and device manufacturers to develop effective quality assurance methods and improved devices for leukocyte-reduced platelet preparation. White cell (WBC) counting methods capable of counting WBCs substantially below 1,000 WBC/mL enhance these activities. The purpose of this study was to enhance and validate a method capable of counting 5-10 WBC/mL in platelets. Methods: We added marker chicken red blood cells (cRBC) at a known concentration to an aliquot of platelet concentrate containing propidium iodide stain solution (PI). A modified BD FACScan(TM) was used to analyze this mixture. The ratio of cRBC and WBC events observed was used with the cRBC concentration to calculate the WBC concentration. Validation was performed by analyzing standard curves prepared with leukocyte-depleted platelet diluent. Methods of preparing leukocyte-reduced platelets by apheresis and filtration were evaluated using this method. Results: The method was linear from 5,000 WBC/mL to 10 WBC/mL (r(2) = 0.983). Residual WBCs in the platelet diluent hampered validation below 10 WBC/mL. Repeatability (CV) was 44% at 8 WBC/mL and 6.5% at 1,000 WBC/mL. The FACScan(TM) required frequent mixing of the sample and flushing with cleaning agents during acquisition. Conclusions: This method has good linearity and reproducibility from 10-5,000 WBC/mL for platelets. It is suited for research and development work, and may be a useful adjunct method for quality assurance in the blood center. (C) 1996 Wiley-Liss, Inc.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 15 条
[1]   SAMPLING ERRORS AND THE PRECISION ASSOCIATED WITH COUNTING VERY LOW NUMBERS OF WHITE CELLS IN BLOOD COMPONENTS [J].
DUMONT, LJ .
TRANSFUSION, 1991, 31 (05) :428-432
[2]   Practical guidelines for process validation and process control of white cell-reduced blood components: Report of the biomedical excellence for safer transfusion (BEST) working party of the international society of blood transfusion (ISBT) [J].
Dumont, LJ ;
Dzik, WH ;
Rebulla, P ;
Brandwein, H .
TRANSFUSION, 1996, 36 (01) :11-20
[3]   FLOW-CYTOMETRIC METHOD FOR COUNTING VERY LOW NUMBERS OF LEUKOCYTES IN PLATELET PRODUCTS [J].
DZIK, WH ;
RAGOSTA, A ;
CUSACK, WF .
VOX SANGUINIS, 1990, 59 (03) :153-159
[4]  
Elfath M., 1995, Blood, V86, p545A
[5]   CANADIAN RED-CROSS SOCIETY SYMPOSIUM ON LEUKODEPLETION - REPORT OF PROCEEDINGS [J].
FREEDMAN, JJ ;
BLAJCHMAN, MA ;
MCCOMBIE, N .
TRANSFUSION MEDICINE REVIEWS, 1994, 8 (01) :1-14
[6]   WHITE CELL-REDUCTION IN PLATELET CONCENTRATES AND PACKED RED-CELLS BY FILTRATION - A MULTICENTER CLINICAL-TRIAL [J].
KAO, KJ ;
MICKEL, M ;
BRAINE, HG ;
DAVIS, K ;
ENRIGHT, H ;
GERNSHEIMER, T ;
GILLESPIE, MJ ;
KICKLER, TS ;
LEE, EJ ;
MCCULLOUGH, JJ ;
MCFARLAND, JG ;
NEMO, GJ ;
NOYES, WD ;
SCHIFFER, CA ;
SELL, K ;
SLICHTER, SJ ;
WOODSON, RD .
TRANSFUSION, 1995, 35 (01) :13-19
[7]  
KLEIN HG, 1992, BLOOD, V80, P1865
[8]  
KLEIN HG, 1994, STANDARDS BLOOD BANK, P13
[9]  
LOMBARDO JF, 1993, J LAB CLIN MED, V122, P557
[10]   LARGE-VOLUME HEMOCYTOMETER CHAMBER FOR ACCURATE COUNTING OF WHITE CELLS (WBCS) IN WBC-REDUCED PLATELETS - VALIDATION AND APPLICATION FOR QUALITY-CONTROL OF WBC-REDUCED PLATELETS PREPARED BY APHERESIS AND FILTRATION [J].
LUTZ, P ;
DZIK, WH .
TRANSFUSION, 1993, 33 (05) :409-412