A comparison of four algorithms for metal artifact reduction in CT imaging

被引:6
|
作者
Golden, Caroline [1 ,2 ]
Mazin, Samuel R. [2 ]
Boas, F. Edward [2 ]
Tye, Grace [2 ]
Ghanouni, Pejman [2 ]
Gold, Garry [3 ]
Sofilos, Marc [2 ]
Pelc, Norbert J. [2 ,4 ]
机构
[1] Natl Univ Ireland Galway, Univ Rd, Galway, Ireland
[2] Stanford Univ, Richard M Lucas Ctr Imaging, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
关键词
ALG; CT; CTREC;
D O I
10.1117/12.878896
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Streak artifacts caused by the presence of metal have been a significant problem in CT imaging since its inception in 1972. With the fast evolving medical device industry, the number of metal objects implanted in patients is increasing annually. This correlates directly with an increased likelihood of encountering metal in a patient CT scan, thus necessitating the need for an effective and reproducible metal artifact reduction (MAR) algorithm. Previous comparisons between MAR algorithms have typically only evaluated a small number of patients and a limited range of metal implants. Although the results of many methods are promising [1-4], the reproducibility of these results is key to providing more tangible evidence of their effectiveness. This study presents a direct comparison between the performances, assessed by board certified radiologists, of four MAR algorithms: 3 non-iterative and one iterative method, all applied and compared to the original clinical images. The results of the evaluation indicated a negative mean score in almost all uses for two of the non-iterative methods, signifying an overall decrease in the diagnostic quality of the images, generally due to perceived loss of detail. One non-iterative algorithm showed a slight improvement. The iterative algorithm was superior in all studies by producing a considerable improvement in all uses.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] An evaluation of three commercially available metal artifact reduction methods for CT imaging
    Huang, Jessie Y.
    Kerns, James R.
    Nute, Jessica L.
    Liu, Xinming
    Balter, Peter A.
    Stingo, Francesco C.
    Followill, David S.
    Mirkovic, Dragan
    Howell, Rebecca M.
    Kry, Stephen F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1047 - 1067
  • [22] Feasibility study of virtual monochromatic imaging for metal artifact reduction in spectral CT
    Lee, Minjae
    Lee, Donghoon
    Kim, Hyemi
    Kim, Dohyeon
    Son, Junyoung
    Kim, Hee-Joung
    INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [23] ARTIFACT REDUCTION IN GATED CARDIAC CT IMAGING
    CHESLER, DA
    PELC, NJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (05) : 716 - 716
  • [24] Iterative deblurring for CT metal artifact reduction
    Wang, G
    Snyder, DL
    OSullivan, JA
    Vannier, MW
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) : 657 - 664
  • [25] Advances in metal artifact reduction in CT images: A review of traditional and novel metal artifact reduction techniques
    Selles, Mark
    van Osch, Jochen A. C.
    Maas, Mario
    Boomsma, Martijn F.
    Wellenberg, Ruud H. H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 170
  • [26] A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
    Oliver Watzke
    Willi A. Kalender
    European Radiology, 2004, 14 : 849 - 856
  • [27] A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
    Watzke, O
    Kalender, WA
    EUROPEAN RADIOLOGY, 2004, 14 (05) : 849 - 856
  • [28] Metal Artifact Reduction of CT Scans to Improve PET/CT
    van der Vos, Charlotte S.
    Arens, Anne I. J.
    Hamill, James J.
    Hofmann, Christian
    Panin, Vladimir Y.
    Meeuwis, Antoi P. W.
    Visser, Eric P.
    de Geus-Oei, Lioe-Fee
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (11) : 1867 - 1872
  • [29] Application of a CT metal artifact reduction method using monoenergetic imaging to RT planning
    Baer, E.
    Kuchenbecker, S.
    Sterzing, F.
    Schwahofer, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S258 - S259
  • [30] Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging
    Abdoli, Mehrsima
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    MEDICAL PHYSICS, 2012, 39 (06) : 3343 - 3360