Impacts of applied voltage on microbial electrolysis cell-anaerobic membrane bioreactor (MEC-AnMBR) and its membrane fouling mitigation mechanism

被引:111
作者
Ding, Aqiang [1 ]
Fan, Qin [1 ]
Cheng, Ran [1 ]
Sun, Guodong [1 ]
Zhang, Mingjie [1 ]
Wu, Donglei [1 ]
机构
[1] Zhejiang Univ, Dept Environm Engn, Coll Environm & Resource Sci, Hangzhou, Zhejiang, Peoples R China
关键词
MEC-AnMBR; Voltage optimization; COD removal efficiency; Membrane fouling; Zeta potential; Extracellular polymeric substance; WASTE-WATER TREATMENT; HOLLOW-FIBER MEMBRANE; ACTIVATED-SLUDGE; EXTRACELLULAR POLYMERS; ELECTRIC-FIELD; PERFORMANCE; FILTRATION; REACTOR; SYSTEM;
D O I
10.1016/j.cej.2017.09.190
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Anaerobic membrane bioreactor (AnMBR) is an efficient technology to treat high concentration wastewater, however membrane fouling is the major limiting factor for its widely application. This study brought the electric field into AnMBR system to couple microbial electrolysis cell (MEC) with AnMBR thus built a new type of MEC-AnMBR reactor. We explored the degradation effect of organic pollutants and membrane fouling in the reactor under different conditions. Results indicated that the chemical oxygen demand (COD) removal rate reached maximum when applied voltage was 0.6 V, and it was almost 1.2 times higher than that without applied voltage (0 V). On the other hand, the membrane fouling rate of MEC-AnMBR reactor gradually slowed down with the increase of applied voltage. The cycle of membrane fouling could be extended from 60 to 98 h. Experimental results suggested that the major reason was the decrease of extracellular polymeric substance-protein (EPSp)/extracellular polymeric substance-polysaccharide (EPSc) ratio of sludge while along with the increase of applied voltage. The increased applied voltage would result in increase of absolute value of zeta potential of sludge particles and decrease of sludge viscosity. The development of MEC-AnMBR has significant effects on high-concentration organic wastewater treatment and the improvement of AnMBR.
引用
收藏
页码:630 / 635
页数:6
相关论文
共 38 条
  • [1] Development of a novel fouling suppression system in membrane bioreactors using an intermittent electric field
    Akamatsu, Kazuki
    Lu, Wei
    Sugawara, Takashi
    Nakao, Shin-ichi
    [J]. WATER RESEARCH, 2010, 44 (03) : 825 - 830
  • [2] [Anonymous], [No title captured]
  • [3] Antifouling nanofiltration membranes for membrane bioreactors from self-assembling graft copolymers
    Asatekin, Ayse
    Menniti, Adrienne
    Kang, Seoktae
    Elimelech, Menachem
    Morgenroth, Eberhard
    Mayes, Anne M.
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2006, 285 (1-2) : 81 - 89
  • [4] [蔡春光 Cai Chunguang], 2004, [中国环境科学, China Environmental Science], V24, P623
  • [5] Chang I. S., 2014, J ENVIRON ENG SCI, V128, P1018
  • [6] Impact of reactor configurations on the performance of a granular anaerobic membrane bioreactor for municipal wastewater treatment
    Chen, Cheng
    Guo, Wenshan
    Ngo, Huu Hao
    Chang, Soon Woong
    Dinh Duc Nguyen
    Phuoc Dan Nguyen
    Xuan Thanh Bui
    Wu, Yun
    [J]. INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2017, 121 : 131 - 138
  • [7] Brewery wastewater treatment using an anaerobic membrane bioreactor
    Chen, Han
    Chang, Sheng
    Guo, Qingbin
    Hong, Youngseck
    Wu, Ping
    [J]. BIOCHEMICAL ENGINEERING JOURNAL, 2016, 105 : 321 - 331
  • [8] Direct Biological Conversion of Electrical Current into Methane by Electromethanogenesis
    Cheng, Shaoan
    Xing, Defeng
    Call, Douglas F.
    Logan, Bruce E.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (10) : 3953 - 3958
  • [9] INFLUENCE OF CULTURE CONDITIONS ON BIOFILM FORMATION BY ESCHERICHIA-COLI O157-H7
    DEWANTI, R
    WONG, ACL
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1995, 26 (02) : 147 - 164
  • [10] Dignac MF, 1998, WATER SCI TECHNOL, V38, P45, DOI 10.2166/wst.1998.0789