Freehand three-dimensional ultrasound to assess semitendinosus muscle morphology

被引:31
|
作者
Haberfehlner, Helga [1 ,2 ]
Maas, Huub [1 ]
Harlaar, Jaap [2 ]
Becher, Jules G. [2 ]
Buizer, Annemieke I. [2 ]
Jaspers, Richard T. [1 ]
机构
[1] Vrije Univ Amsterdam, MOVE Res Inst Amsterdam, Fac Behav & Movement Sci, Lab Myol,Dept Human Movement Sci, Boechorststr 9, NL-1081 BT Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, MOVE Res Inst Amsterdam, Dept Rehabil Med, Med Ctr, Amsterdam, Netherlands
关键词
three-dimensional ultrasonography; geometry; hamstrings; muscle architecture; KNEE FLEXION CONTRACTURE; GASTROCNEMIUS-MUSCLE; IN-VIVO; ARCHITECTURE; SYSTEM; DEPENDENCE; CHILDREN; LENGTHS; GROWTH; IMAGE;
D O I
10.1111/joa.12501
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
In several neurological disorders and muscle injuries, morphological changes of the m. semitendinosus (ST) are presumed to contribute to movement limitations around the knee. Freehand three-dimensional (3D) ultrasound (US), using position tracking of two-dimensional US images to reconstruct a 3D voxel array, can be used to assess muscle morphology invivo. The aims of this study were: (i) to introduce a newly developed 3D US protocol for ST; and (ii) provide a first comparison of morphological characteristics determined by 3D US with those measured on dissected cadaveric muscles. Morphological characteristics of ST (e.g. muscle belly length, tendon length, fascicle length and whole muscle volume, and volumes of both compartments) were assessed in six cadavers using a 3D US protocol. Subsequently, ST muscles were removed from the body to measure the same morphological characteristics. Mean differences between morphological characteristics measured by 3D US and after dissection were smaller than 10%. Intra-class correlation coefficients (ICCs) were higher than 0.75 for all variables except for the lengths of proximal fascicles (ICC=0.58). Measurement of the volume of proximal compartment by 3D US was not feasible, due to low US image quality proximally. We conclude that the presented 3D US protocol allows for reasonably accurate measurements of key morphological characteristics of ST muscle.
引用
收藏
页码:591 / 599
页数:9
相关论文
共 50 条
  • [1] Freehand three-dimensional ultrasound: Implementation and applications
    Sherebrin, S
    Fenster, A
    Rankin, R
    Spence, D
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 296 - 303
  • [2] Freehand three-dimensional ultrasound system for assessment of scoliosis
    Cheung, Chung-Wai James
    Zhou, Guang-Quan
    Law, Siu-Yin
    Lai, Ka-Lee
    Jiang, Wei-Wei
    Zheng, Yong-Ping
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2015, 3 (03) : 123 - 133
  • [3] A generalized method for freehand three-dimensional ultrasound acquisition
    Bouchet, L
    Bova, F
    Meeks, S
    Friedman, W
    MEDICAL PHYSICS, 2002, 29 (06) : 1291 - 1291
  • [4] Rotational motion in sensorless freehand three-dimensional ultrasound
    Housden, R. J.
    Gee, Andrew H.
    Prager, Richard W.
    Treece, Graham M.
    ULTRASONICS, 2008, 48 (05) : 412 - 422
  • [5] Surface extraction with a three-dimensional freehand ultrasound system
    Zhang, WY
    Rohling, RN
    Pai, DK
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (11): : 1461 - 1473
  • [6] Three-dimensional realisation of muscle morphology and architecture using ultrasound
    Fry, NR
    Gough, M
    Shortland, AP
    GAIT & POSTURE, 2004, 20 (02) : 177 - 182
  • [7] Defining tibial anterior muscle morphology in first-ever chronic stroke patients using three-dimensional freehand ultrasound
    Schillebeeckx, Fabienne
    Duyck, Julien
    Plessers, Anouk
    Agostini, Adele
    Vander Poorten, Sandor
    Hanssen, Britta
    Desloovere, Kaat
    Verheyden, Geert
    Peers, Koen
    TOPICS IN STROKE REHABILITATION, 2024, 31 (08) : 838 - 851
  • [8] Reliability of freehand three-dimensional ultrasound to measure scapular rotations
    Worobey, Lynn A.
    Udofa, Ima A.
    Lin, Yen-Sheng
    Koontz, Alicia M.
    Farrokhi, Shawn S.
    Boninger, Michael L.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2014, 51 (06): : 985 - 994
  • [9] Three-dimensional freehand ultrasound: Image reconstruction and volume analysis
    Depts. of Cardiovasc./Musculoskel., Zeneca Pharmaceuticals, Alderley Park, Macclesfield, Cheshire SK10 4TG, United Kingdom
    不详
    不详
    ULTRASOUND MED. BIOL., 8 (1209-1224):
  • [10] Three-dimensional freehand ultrasound: Image reconstruction and volume analysis
    Barry, CD
    Allott, CP
    John, NW
    Mellor, PM
    Arundel, PA
    Thomson, DS
    Waterton, JC
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08): : 1209 - 1224