Comparison of the PFC sigma fixed-bearing and rotating-platform total knee arthroplasty in the same patient - Short-term results

被引:64
作者
Ranawat, AS
Rossi, R
Loreti, I
Rasquinha, VJ
Rodriguez, JA
Ranawat, CS
机构
[1] Ranawat Orthopaed Ctr, New York, NY 10021 USA
[2] Univ Turin, Turin, Italy
[3] Rizzoli Orthopaed Inst, Biomech Lab, Bologna, Italy
关键词
total knee arthroplasty; mobile-bearing; rotating-platform; fixed-bearing; patient outcomes;
D O I
10.1016/j.arth.2003.08.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This Study compares the fixed-bearing PFC Sigma Total Knee Arthroplasty to the recently introduced rotating-platform version of the same design in 26 patients. At an average follow-Lip time of 46 months for the fixed-bearing side and 16 months for the rotating-platform side, no significant differences were found in terms of knee preference, knee pain, range of motion, overall satisfaction, or Knee Society scores (KSSs). No revisions, subluxations, dislocations, or infections were seen. Also no radiographic evidence of component loosening, osteolysis, or malalignment was found in any knee. The results of cementing the PFC Sigma rotating-platform, posterior-stabilized total knee show excellent patient satisfaction at 1 year and comparable clinical and radiographic results to the fixed-bearing version.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 26 条
[1]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[2]  
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
[3]   THE NEW-JERSEY LOW-CONTACT-STRESS KNEE REPLACEMENT SYSTEM - BIOMECHANICAL RATIONALE AND REVIEW OF THE 1ST 123 CEMENTED CASES [J].
BUECHEL, FF ;
PAPPAS, MJ .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 105 (04) :197-204
[4]  
BUECHEL FF, 1990, CLIN ORTHOP RELAT R, V260, P162
[5]  
BUECHEL FF, 2001, CLIN ORTHOP RELAT R, V388, P41
[6]   Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[7]  
CALLAGHAN JJ, 2001, CLIN ORTHOP RELAT R, V392, P221
[8]  
D'Lima DD, 2000, CLIN ORTHOP RELAT R, P151
[9]   Total knee replacement in young, active patients - Long-term follow-up and functional outcome [J].
Diduch, DR ;
Insall, JN ;
Scott, WN ;
Scuderi, GR ;
FontRodriguez, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (04) :575-582
[10]  
DLIMA DD, 2001, CLIN ORTHOP RELAT R, V386, P235