Development of Functional Electrical Stimulation Rowing: The Rowstim Series

被引:21
作者
Andrews, Brian [1 ,2 ]
Gibbons, Robin [3 ]
Wheeler, Garry [4 ]
机构
[1] Univ Warwick, Sch Engn, Coventry CV4 7AL, W Midlands, England
[2] Univ Oxford, Nuffield Dept Surg Sci, Oxford, England
[3] UCL, CREATe, London, England
[4] MS Soc Alberta, Edmonton, AB, Canada
基金
英国工程与自然科学研究理事会;
关键词
Adaptive Rowing; Functional electrical stimulaton; Spinal cord injury; Exercise; SPINAL-CORD-INJURY; WHEELCHAIR USERS; BONE METABOLISM; EXERCISE; INDIVIDUALS; FITNESS; PEOPLE; IMMOBILIZATION; DENSITY; QUALITY;
D O I
10.1111/aor.13053
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Potentially, functional electrical stimulation (FES)-assisted exercise may have an important therapeutic role in reducing comorbidities associated with spinal cord injury (SCI). Here, we present an overview of these secondary life-threatening conditions, discuss the rationale behind the development of a hybrid exercise called FES rowing, and describe our experience in developing FES rowing technology. FES rowing and sculling are unique forms of adaptive rowing for those with SCI. The paralyzed leg musculature is activated by multiple channels of electrical pulses delivered via self-adhesive electrodes attached to the skin. The stimulated muscle contractions are synchronized with voluntary rowing movements of the upper limbs. A range of steady-state FES rowing exercise intensities have been demonstrated from 15.2 +/- 1.8 mL/kg/min in tetraplegia to 22.9 +/- 7.1 mL/kg/min in paraplegia. We expect that such high levels may help some to achieve significant reductions in the risks to their health, particularly where a dose-response relationship exists as is the case for cardiovascular disease and Type II diabetes. Furthermore, preliminary results suggest that cyclical forces more than 1.5 times body weight are imposed on the leg long bones which may help to reduce the risk of fragility fractures. We have demonstrated the feasibility of FES rowing on land and water using adapted rowing technology that includes; a fixed stretcher indoor ergometer (adapted Concept 2, Model E), a floating stretcher indoor ergometer (adapted Concept 2 Dynamic), a turbine powered water rowing tank, a custom hydraulic sculling simulator and a single scull (adapted Alden 16). This has involved volunteers with paraplegia and tetraplegia with SCI ranging from C4 to T12 AIS A using at least 4-channels of surface electrical stimulation. FES rowers, with SCI, have competed alongside non-SCI rowers over the Olympic distance of 2000 m at the British Indoor Rowing Championships in 2004, 2005, and 2006 and the World Indoor Rowing Championships in 2006 (CRASH-B's) in Boston, MA, USA. The best 2000 m FES rowing performance to date has been achieved by a 23-year-old male, Tom Aggar T12 AIS A, in 10 min 28 s. Moreover, two of our FES rowers with complete paraplegia have gone on to successfully compete in the Adaptive Rowing arms-only category (AM1x) at the World Rowing Championships and Paralympic Games.
引用
收藏
页码:E203 / E212
页数:10
相关论文
共 50 条
  • [21] High-intensity interval training with functional electrical stimulation cycling for incomplete spinal cord injury patients: A pilot feasibility study
    Manaf, Haidzir
    Hamzaid, Nur Azah
    Hasnan, Nazirah
    Yiwei, Chen
    Mohafez, Hamidreza
    Hisham, Hafifi
    Davis, Glen
    ARTIFICIAL ORGANS, 2024, 48 (12) : 1449 - 1457
  • [22] Functional Electrical Stimulation in Clinical Applications: Fitness and Cardiovascular Health
    Davis, G. M.
    Hamzaid, N. A.
    Hasnan, N.
    2014 IEEE 19TH INTERNATIONAL FUNCTIONAL ELECTRICAL STIMULATION SOCIETY ANNUAL CONFERENCE (IFESS), 2014,
  • [23] Cadence control system for paediatric functional electrical stimulation cycling
    Pennycott, A.
    Hunt, K. J.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2010, 5 (03) : 237 - 242
  • [24] Functional electric stimulation-assisted rowing: Increasing cardiovascular fitness through functional electric stimulation rowing training in persons with spinal cord injury
    Wheeler, GD
    Andrews, B
    Lederer, R
    Davoodi, R
    Natho, K
    Weiss, C
    Jeon, J
    Bhambhani, Y
    Steadward, RD
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (08): : 1093 - 1099
  • [25] Functional Electrical Stimulation Therapy for Retraining Reaching and Grasping After Spinal Cord Injury and Stroke
    Kapadia, Naaz
    Moineau, Bastien
    Popovic, Milos R.
    FRONTIERS IN NEUROSCIENCE, 2020, 14
  • [26] Lessons from Vienna: stakeholder perceptions of functional electrical stimulation technology and a conceptual model for practice
    Taylor, Matthew J.
    Ruys, Andrew J.
    Fornusek, Che
    Bijak, Manfred
    Russold, Michael
    Bauman, Adrian E.
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2020, 15 (01) : 37 - 44
  • [27] Cadence Tracking and Disturbance Rejection in Functional Electrical Stimulation Cycling for Paraplegic Subjects: A Case Study
    da Fonseca, Lucas O.
    Bo, Antonio P. L.
    Guimaraes, Juliana A.
    Gutierrez, Miguel E.
    Fachin-Martins, Emerson
    ARTIFICIAL ORGANS, 2017, 41 (11) : E185 - E195
  • [28] Functional electrical stimulation
    Ichie, M
    Handa, Y
    NEUROLOGICAL SURGERY, 2001, 29 (01): : 11 - 20
  • [29] Cardiorespiratory responses during functional electrical stimulation cycling and electrical stimulation isometric exercise
    Fornusek, C.
    Gwinn, T. H.
    Heard, R.
    SPINAL CORD, 2014, 52 (08) : 635 - 639
  • [30] Can functional electric stimulation-assisted rowing reproduce a race-winning rowing stroke?
    Halliday, SE
    Zavatsky, AB
    Hase, K
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (08): : 1265 - 1272